This overview was published in the Chemisch2Weekblad, 98 (2002-18) 32-45 .
Supplier | System | Type mass analyser | Mass (m/z)-range | Ionisation techniques | Data acquisition and processing software | Compatibility in control of GC systems | Remarks |
Agilent Technologies | Agilent 5973-N | single-quadrupole | 800 | EI, PCI, NCI | Agilent-MSD Chemstation | Agiilent-6890 | spectral libraries available |
THERMO FINNIGAN | TraceDSQ | single-quadrupole | 1-1050 | EI, PCI, NCI en EI/CI combibron | Xcalibur (Windows 2000) | TraceGC | curved prefilter-technology; probes and digital CI-control, 10.000 amu/sec to 50 scans per second, SIM and Fullscan simultaneous |
THERMO FINNIGAN | Polaris-Q | ion-trap | 10-1000 | EI, PCI, NCI | Xcalibur (Windows 2000) | TraceGC | External Ionisation, MS-MS, Probes, NCI and digital CI-control |
THERMO FINNIGAN | Tempus | TOF | 2-1000 | EI, PCI, NCI | Xcalibur (Windows 2000) | TraceGC (with Ultra Fast Option, up to 1200 C/min) | Benchtop, >100 scans/sec, >10^5 dynamic range. |
JEOL (EUROPE) B.V. | GCMate II | magnetic sector, double focusing | 2500 | EI, PCI, NCI, FAB | Jeol software (Windows) | Agilent-6890 | 5000 Resolution, Benchtop Model, Full Automatic Probe Analysis, MS/MS Linked scan |
JEOL (EUROPE) B.V. | Mstation JMS-700 | magnetic sector, double focusing | 25000 | EI, PCI, NCI, FAB, FD, FI, DCI, | Jeol software | Agilent-6890 | 60000 resolution. Dedicated dioxine version avialable. |
Micromass | GCT | time-of-flight | 1500 | EI, PCI, NCI, FI | MassLynx 4.0 (Windows XP, NT or Windows 2000), MassLynx is CFR 21 part 11 complaint.; Various integrated couplings to, e.g., AMDIS,.NIST, ACD, nugenesis | Agilent-6890, various injectors, e.g., CTC Pal | Resolution 7000 at 3.5 GHz TDC; better than 1 mDa at m/z < 200, better than 5 ppm at m/z > 200; Solids-probe option |
Micromass | Quattro-Micro | triple-quadrupole | 1200 | EI, PCI, NCI, | Agilent-6890, various injectors, e.g., CTC Pal | Bechtop MS-MS, Solids-probe option | |
Micromass | AutoSpec | magnetic sector, double focusing | vanaf 3000 | EI, CI, and all other ionisation technologies available: FI, FAB, ESI, APCI, MALDI | Agilent-6890, various injectors, e.g., CTC Pal | Resolution 60000 (20% valley) | |
PerkinElmer Benelux | Clarus 500 GC/MS | single-quadrupole | 1200 | EI, CI+, CI- | Clarus (Windows NT) | PerkinElmer Clarus 500 GC | PCI/NCI option, SIFI Mode with Simultaneous Full Scan and SIM, LVI and MS Vent (column backflush or column change under vacuum) Touchscreen monitoring |
Shimadzu | QP5000 and QP5050A | single-quadrupole | 700 (QP5000); 900 (QP5050A) | EI, PCI, NCI combination CI and SEI | GCMSsolutions (windows 2000, NT) | Shimadzu GC-17A | Direct Insertion probe and Pyrolysis unit available, spectral libraries, Suitable for fast GC-MS |
Shimadzu | QP2010 | single-quadrupole | 1.5 - 1024 | EI, PCI, NCI combination CI and SEI | GCMSsolutions with MS Navigator (Windows 2000) | Shimadzu GC2010 (+FID) | Sensitivity in sub femtogram range (10-15 gr); Fast GC (10000amu/sec); new ion optics, High End GCMS |
Thermo Finnigan | MAT95 XP GC-MS | magnetic sector, double focusing (BE) | 3500 Da at maximum acceleration | EI, PCI, NCI, FAB, FD/FI. | Xcalibur (Windows 2000) | Trace 2000 and Agilent 6890 | DIP en DCI probes as Option. Ion-Trap option for MS-MS available. Dedicated dioxine analysis system available. |
Thermo Finnigan | MAT900 XL GC-MS | magnetic sector, double focusing (EB) | 5000 Da at maximum acceleration | EI, PCI, NCI, FAB, FD/FI. | Xcalibur (Windows 2000) | Trace 2000 and Agilent 6890 | DIP en DCI probes as Option. Ion-Trap option for MS-MS available. PATRIC detector as option |
Varian Chrompack | Saturn 2100 | ion-trap | 650 | EI, CI, | Star vs. 5 (Windows 95,98,NT, 2000) | Varian CP-3900 | MS-MS, SIS, liquid CI |
Varian Chrompack | Saturn 2200 | ion-trap | 650 | EI, CI | Star vs. 5 (Windows 95,98,NT, 2000) | Varian CP-3800 | MS-MS, SIS, liquid CI |
Varian Chrompack | 1200 Single-quadrupole | single-quadrupole | 800, (1500) | EI, PCI, NCI | Paw software (Windows 2000) | Varian CP-3800 | Probe, vacuum interlock, possibility to upgrade to LC-MS-MS and GC-MS-MS |
Varian Chrompack | 1200 Triple-quadrupole | triple-quadrupole | 800, (1500) | EI, PCI, NCI | Paw software (Windows 2000) | Varian CP-3800 | MS-MS, probe, vacuum interlock, curved collision cell, possibility to upgrade to LC-MS-MS |