Specifications Power Requirements: Model Input Voltage Power41342V option 8-24 VDC5 mA @ 12 VDC L option 12-30 VDC20 mA max 41382V option 8-30 VDC7 mA @ 12 VDC L option 5-30 VDC46 mA max RELATIVE HUMIDITY: (41382) Measuring Range: 0-100 %RH Accuracy at 23°C: ±1%RH, Stability: Better than ±1%RH per year Response Time: 10 seconds (without filter) Sensor Type: Rotronic Hygromer™ Output Signal: V option: 0-1 VDC, L option: 4-20 mA TEMPERATURE: (41382, 41342) Calibrated Measuring Range: -50 to 50°C (suffix C) -50 to 150°F (suffix F) Response Time: 10 seconds (without filter) Accuracy at 23°C: ±0.3°C /optional ±0.1°C NIST calibration - 41342 only Sensor Type: Platinum RTD Output Signal: V Option: 0-1 VDC, L Option: 4-20 mA, 4 wire RTD (41342 only)
Recommended Radiation Shields: Model 41003P Multi-Plate Radiation Shield Model 43502 Aspirated Radiation Shield |