PSS Nicomp 380 DLS-CS 纳米粒度分析仪
PSS Nicomp 380 DLS-CS 纳米粒度分析仪
PSS Nicomp 380 DLS-CS 纳米粒度分析仪
PSS Nicomp 380 DLS-CS 纳米粒度分析仪
PSS Nicomp 380 DLS-CS 纳米粒度分析仪

PSS Nicomp 380 DLS-CS 纳米粒度分析仪

参考价:¥40万
型号: PSS Nicomp 380 DLS-CS
产地: 美国
品牌: 美国PSS
评分:
核心参数
关注展位 全部仪器
展位推荐 更多
产品详情

      

PSS Nicomp 380 DLS-CS 纳米粒度分析仪

型号:PSS Nicomp 380 DLS-CS 纳米粒度分析仪

PSS Nicomp 380 DLS-CS 纳米粒度分析仪,采用雪崩二极管(APD)检测器和大功率激光器,大功率激光器可以增加光强度,APD检测器更是增加了对微小粒子所发出信号的探测能力。利用布朗运动及动态光散射理论,粒径检测范围为0.3nm – 10μm,可以给出所测样品的粒度分布,纳米级别粒径分布测定更加精准。


The Nicomp 380 was specifically designed to measure nano-sized particles as well as other colloidal systems. From approximately 0.5 nm to 6 microns the 380 has been the instrument of choice for researchers and top notch scientists for years. Its unique features such as base-line adjust for automatic aggregate compensation and a proprietary high resolution multi-modal algorithm has historically proven its ability to separate close bimodals and native populations from aggregate tails.

 

Highlights

 

Wide Dynamic Range

0.5 nanometers to 6 microns

Absolute meaurement

does not require calibration

Large representative sample is measured quickly

High sensitivity

relatively high sensitivity to aggregate populations (D6)

Analytical function

assumed for particle size analysis

 

Dynamic Light Scattering

The Nicomp 380 Submicron Particle Size Analyzer uses the principle of Dynamic Light Scattering (DLS) to obtain the partcile size distribution of colloidal systems whose sizes range from 0.5 nanomters to 6 microns. DLS works by illuminating a group of particles in suspension with a focused laser beam which gives rise to many scattered light waves. These waves interfere with each other and produce a net scattered intensity that fluctuates as a function of time at some distant detector. Diffusion, or Brownian motion, of the particles causes random variations in the phases of the individual waves, resulting in a fluctuating light intensity. The particle size distribution can be obtained by analyzing the time behavior of these fluctuations using an autocorrelator. The autocorrelation function for a single uniform size distribution is a decaying exponential function where particle diffusivity is easily obtained from the decay time. Finally the particle radius can easily be calculated using the Stokes-Einstein relationship.

In general most samples are not uniform instead they are quite often polydisperse, having a range of particle sizes. The autocorrelation function then consists of a combination of decaying exponential functions, each having a different decay time and the analysis of the autocorrelation function is no longer quite simple. The instrument using varying deconvolution algorithms must invert the raw data in order to arrive at the best estimate of the true particle size distribution. The Nicomp excels at characterizing these difficult particle size distributions by utilizing a group of unique deconvolution algorithms ranging from a simple Gaussian approximation to a proprietary high resolution multi-modal deconvolution analyses called the “Nicomp Distribution".

Some of the unique features found on Gaussian analysis mode is a baseline adjust parameter which provides aggregate compensation that excedes the sensitivity found on most other instruments which employ a dust or dirt factor. The Gaussian analysis mode also allows for the user to specify a solid or vesicle weighting mode for analysing thin walled colloidal systems like liposomes. The Nicomp Analysis Mode is a proprietary high-resolution deconvolution algorithm that was first introduced over 25 years ago. It has historically proven its ability to accurately analyze even the most difficult closely spaced bimodals (e.g. 2:1 apart) and even certain trimodal distributions. This is extremely useful in finding the native peak of the aggregate distribution.

Dynamic Light Scattering 4

The standard Nicomp 380 is equipped with a 12 mW laser diode and PMT detector with an optical fiber set to 90°. Sample is introduced with drop-in cells.

The 380 is the only Dynamic Light Scattering Instrument designed using a modular approach. Its capabilities may be enhanced by adding one or more modules:

Autodilution

This patented module eliminates the need for manual dilution of concentrated sample. Autodilution makes particle size analysis quick and easy, with no training required. Results are highly reproducible.

380/HPLD High Power Laser Diodes

PSS offers an array of high power laser diodes to meet the needs of our most demanding applications. Higher power lasers are needed to extend the lower limit of our instrument by providing adequate scattering from small particles. They are also useful when measuring large particles such as dextrans, which yield insufficient scattering intensity because of index of refraction properties. The result is a more versatile instrument, ideal for sizing microemulsions, surfactant micelles, proteins and other macromolecules. It can even estimate the extent of aggregration of biopolymers after reconstitution, without chromatographic separation.

Avalanche Photo Diode (APD) Detector

The Nicomp 380 can be equipped with various high-powered lasers as well as a high-gain Avalanche Photo Diode Detector (APD which provides approxi-mately seven times the gain of a conventional photomultiplier tube. The APD is used to increase signal-to-noise and sensitivity in systems that do not scatter light well. Proteins, micelles, other macro-molecular-based systems, and nanopar-ticles are often dilute (1 mg/ml or less) and are made of atoms that do not scatter light well. The Avalanche Photo Diode coupled with a nominally higher powered laser diode module offers a low cost solution for accurately analyzing nanoparticles in a short period of time.

380/MA Multi-angle Goniometer

Particles larger than 100 nm do not scatter light isotropically in all directions. It is possible to make DLS measurements more sensitive to certain sized particles by changing the angle of detection. The Nicomp 380 can be equipped with a mini-goniometer that moves the optical fiber between 12° and 175° by 0.9° increments.



上海奥法美嘉生物科技有限公司为您提供美国PSSPSS Nicomp 380 DLS-CS 纳米粒度分析仪,美国PSSPSS Nicomp 380 DLS-CS产地为美国,属于进口激光粒度仪,除了PSS Nicomp 380 DLS-CS 纳米粒度分析仪的参数、价格、型号、原理等信息外,还可为您提供PSS Nicomp N3000动态光散射粒度分析仪、Z3000 纳米粒度仪、PSS Nicomp N3000 纳米粒度仪,上海奥法美嘉客服电话400-801-5771,售前、售后均可联系。

相关仪器 更多
相关资料 更多

相关产品

上海奥法美嘉生物科技有限公司为您提供美国PSSPSS Nicomp 380 DLS-CS 纳米粒度分析仪,美国PSSPSS Nicomp 380 DLS-CS产地为美国,属于进口激光粒度仪,除了PSS Nicomp 380 DLS-CS 纳米粒度分析仪的参数、价格、型号、原理等信息外,还可为您提供PSS Nicomp N3000动态光散射粒度分析仪、Z3000 纳米粒度仪、PSS Nicomp N3000 纳米粒度仪,上海奥法美嘉客服电话400-801-5771,售前、售后均可联系。
Business information
工商信息 信息已认证
当前位置: 上海奥法美嘉 仪器 PSS Nicomp 380 DLS-CS 纳米粒度分析仪

关注

拨打电话

留言咨询