· Injector: Split-splitless (standard)
· Oven temperature: Ambient +4 °C– 450 °C
· Oven ramps/plateaus: 6/7
· Electronic pneumatic control (EPC): Auto pressure regulation for split/splitless, septum purge
· Carrier gas control modes: Constant pressure and flow modes; pressure and flow Programmable
5975VL/SD Mass Spectrometer Specifications:
· Mode (standard) EI
· Ion source type: Noncoated inert EI source
· Mass filter: Monolithic hyperbolic quadrupole
· Maximum mass: 1050 u
· Detector: EM with replaceable horn
· Scan rate (electronic): Up to 10,000 amu/s
· Pumping system: 70 L/s or 262 L/s turbomolecular pump with 2.5 m3/h mechanical pump
Data System
· eMethods: Transfer methods between 5975 and 5973 Series MSDs
· Simultaneous MS and GC: Four signals (up to two MS) detector data acquisitions
· SIM/Scan: Automated SIM setup and synchronous SIM/scan operation
· Application autotunes: One-click autotune for BFB, DFTPP
Overview:
Laboratories worldwide are looking for a GC solution that delivers reliability, performance, and reproducible results, And nothing produces these benefits like the Agilent 6890N Network GC. By integrating leading-edge technologies with an emphasis on quality manufacturing processes, the 6890N will bring a work ethic to your laboratory that’s matched only by your own.
Accomplish more with networking abilities
Lets you share business and scientific data easily within a laboratory and across sites for fast and informed decision making.
Incorporates local area network (LAN) technology as a standard feature, which makes it easy to link communication and control of multiple analytical instruments. With networking, you can work smarter, faster, and more economically.
Increased Laboratory Efficiency
Clock-time programming allows you to set up runs for unattended operation whenever you want. The system can be ready to work when you get to your laboratory. Pre-run and post-run commands automatically prepare the system for the next sample.
Decreased Calibration Time
You can manually enter existing calibration data and make a run with just one standard peak. The system can normalize the calibration table for you, allowing you to cut calibration time and avoid re-running your calibration standards.
High Sample Throughput
The 6890N network GC system is already set up for the Agilent 7683 automatic liquid sampler, enabling fast and easy installation. Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray, allow unattended operation. Using the 11-vial transfer turret with the tray and the solvent saving mode, you have enough solvent to run unattended eight times longer than before.
Minimal Rework
The Agilent 6890N network GC system is the only GC system that automatically selects the optimum pressure-control mode for split and splitless analyses. Forward-pressure control is best for splitless injections. Along with a large inlet liner volume and pressure-pulse operation, this mode reduces discrimination, sample degradation, and sample loss caused by liner overload while maximizing sensitivity. For split injections, the system automatically selects back-pressure control for linear split ratios over the entire usable split-ratio range and over wide column flow and pressure ranges. This reduces sample preparation and increases reproducibility and accuracy. Automatic switching between forward-and back-pressure modes yields optimal results in less time and with less effort.
5975 Features:
Inert ion source—now programmable up to 350°C—delivers enhanced response for active compounds and late eluters
Proprietary hyperbolic quadrupole enhances performance up to 1050 u; the unique stability of the quartz monolith allows the analyzer to be heated to 200°C to eliminate contamination commonly seen at lower temperatures
Trace Ion Detection and the second generation of Deconvolution Reporting Software (DRS) accurately identify and quantify trace components that coelute with other analytes or matrix peaks
Synchronous SIM/Scan mode lets you selectively monitor for ions of interest with high sensitivity SIM while simultaneously acquiring library-searchable scan data
Safe operation with low cost, hydrogen carrier gas—with sensitivity greater than most other GC/MS systems
All ionization modes (PCI, NCI and EI) in one automated sequence using the standard Cl source; AutoCI feature makes CI as easy as EI
High performance and entry level models that are perfectly complemented by the Agilent 7890A GC, 6890 GC, and 6850 GC
MSD Productivity ChemStation for most laboratories and MSD Security ChemStation for laboratories adhering to FDA’s 21 CFR Part 11 guidelines