新势力光电供应美国Wilks公司的InfraCal Soot Meter烟尘仪,是一种ASTM 7686-11认可的用于测量柴油发动机润滑油的碳(煤烟)含量的测量方法。该系列烟尘分析仪具有如下特点:使用方便,检测速度快、测量范围大、无需样品制备和稀释过程,广泛用于润滑剂的评估和筛选,应用场所包括:油品检测实验室、发动机测试实验室、车站维修点、建筑或采矿点、航船、发电站。
InfraCal Soot Meter | Model HATR-CP |
Analytical Wavelength | 3.9μm, 2553cm-1 |
Sample Surface | Cubic Zirconia ATR Crystal |
Display | 4 digit, 7-segment red LED, 5/8 in. character height |
Power Requirements | 12V DC, 2.0A, 12V battery pack or adapter available |
Power Supply | Universal AC/DC (supplied as standard) |
Weight | 2.0kgs |
Dimensions | 165×165×225mm3 |
Suggested Operating Range | 4°C-45°C |
Typical Measurement Range | 0-15% Soot |
Output Resolution | 0.0001 |
Analysis Time | Less than 30 seconds |
Communication Port | RS232 port, 9-pin D-sub Female, PC compatible |
Instrument Repeatability | 0-3% soot ±0.1%, 3-15% soot ±0.3% |
Non-volatile Memory Calibration | Factory: 0-10% soot |
User: Up to 20 point curve fitting calibration, plus zero |
Part Number | Descriptions |
405-0011 | InfraCal Soot Meter Plus, Model HATR-CP. Complete with HATR Sample Stage for direct measurement of suspended carbon (soot) level in diesel engine oils (factory calibrated to 10% soot concentration), Power Supply and Instruction Manual. |
Accessories | |
403-0025 | Set of 6 Reference Oils in dropper bottles, appropriate for calibration and verification of reproducibility 0-12% soot range of Model HATR-CP and Model HATR-C. This set of reference oils has been correlated with the results obtained via thermal gravimetric analysis (TGA) of fresh used diesel oil samples. |
403-0018 | InfraLog Serial Printer Prints calibration and measurement data, complete with sequence number, date and time. Includes all required cables. |
403-0013 | Carrying Case with pre-diced pluck foam, 470×370×203mm3, 3.6kgs. |
403-0003 | External 12V Battery Pack with 120V/60Hz charger (for use in North America). Includes carrying case with shoulder strap and cigarette lighter adapter cable for connection to analyzer. Provides 16 hours of continuous operation. |
403-0002 | Cigarette Lighter Adapter Cable |
403-0005 | Dust Cover |
403-0001 | Universal Switching Power Supply and Line Cord for use with InfraCal Analyzers. 90-264VAC, 50-60Hz input, regulated 12V/25W output |
403-0014 | Replacement Source/Cable Assembly |
100-1005 | InfraCal Soot Meter User's Manual |
100-1011 | InfraCal Soot Meter Plus User's Manual |
Comparative Soot Measurements On Used Diesel Oil Samples | |||||||||
FT-IR, TGA, and InfraCal Soot Meter | |||||||||
Provided by Mobil Oil Company, Paulsboro Technical Center | |||||||||
Field Test Samples | Lab Engine Test Samples | ||||||||
Soot, % mass | Soot, % mass | ||||||||
Sample ID | FT-IR | TGA | Soot Meter 1 | Soot Meter 2 | Engine/Hours | TGA | Soot Meter 1 | Soot Meter 2 | |
A1 | 1.46 |
| 1.4 | 1.4 | Mack T-8 |
|
|
| |
B1 | 1.59 |
| 1.6 | 1.6 | Hours: | 0 | 0.13 | 0.1 | 0.0 |
B2 | 1.82 |
| 1.8 | 1.9 |
| 50 | 1.76 | 1.7 | 1.7 |
B3 | 1.94 |
| 1.9 | 2.0 |
| 100 | 3.13 | 3.2 | 3.1 |
B4 | 2.56 |
| 2.5 | 2.5 |
| 150 | 4.48 | 4.5 | 4.4 |
A2 | 2.74 | 2.65 | 2.6 | 2.6 |
| 175 | 5.16 | 5.0 | 5.0 |
B5 | 2.68 |
| 2.7 | 2.7 |
| 200 | 5.80 | 5.8 | 5.8 |
B6 | 2.81 | 2.76 | 2.8 | 2.9 |
| 225 | 6.38 | 6.1 | 6.0 |
B7 | 2.82 | 2.90 | 2.6 | 2.7 |
| 250 | 6.92 | 6.1 | 6.2 |
B8 |
| 3.15 | 3.0 | 3.1 | DDC Series 60 |
|
|
| |
B9 |
| 3.21 | 3.2 | 3.2 | Hours: | 0 | 0.09 | 0.0 | 0.0 |
B10 |
| 3.53 | 3.3 | 3.1 |
| 24 | 0.83 | 0.8 | 0.8 |
A3 |
| 3.54 | 3.5 | 3.6 |
| 48 | 1.40 | 1.4 | 1.4 |
A4 |
| 4.05 | 4.0 | 4.0 |
| 72 | 1.98 | 1.9 | 1.9 |
A5 |
| 4.40 | 4.3 | 4.4 |
| 96 | 2.52 | 2.5 | 2.5 |
A6 |
| 4.99 | 4.5 | 4.6 |
| 120 | 3.05 | 3.0 | 2.9 |
A7 |
| 6.12 | 5.1 | 5.1 |
| 144 | 3.58 | 3.5 | 3.5 |
A8 |
| 6.47 | 5.7 | 5.7 |
| 168 | 4.10 | 4.0 | 4.1 |
A9 |
| 7.00 | 6.0 | 6.1 |
| 192 | 4.57 | 4.5 | 4.6 |
|
|
|
|
|
| 216 | 5.03 | 4.8 | 4.9 |
|
|
|
|
|
| 240 | 5.33 | 5.0 | 5.0 |
Note: A & B series samples are different oil formulations. | Note: Soot Meter data was obtained using 2 production models. Each was calibrated to 5% soot, which accounts for measurement discrepancy in samples containing a higher percentage. |
Wilks油脂分析仪
InfraSpec VFA-IR光谱仪
Wilks生物燃料分析仪
InfraRan气体分析仪
相关产品
热导式气体分析仪
尘量分析仪
粗、细颗粒物双道采样器
颗粒物采样器
粉尘采样器
降水/降尘自动采样监测仪
气体采样器/大气采样器
空气检测仪(CO、SO2、HCL、NOX)
烟尘采样器、烟气采样器
汽车尾气分析仪
烟气监测(CEMS)/烟气分析仪
VOC检测仪/TVOC检测仪
PM2.5采样器
TSP采样器
PM10采样器
其它气体检测
甲醛检测仪/甲醛分析仪
CO2分析仪、CO分析仪
粉尘测定仪/粉尘仪
气溶胶检测仪/系统
氨气分析仪/氨分析仪
空气微生物采样器
臭氧分析仪(O3)
气体稀释仪
粒子计数器
灰霾监测系统
PM2.5/PM10/PM1/TSP大气颗粒物监测仪
氮氧化物分析仪(NOX)
烟气汞连续监测系统(Hg-CEMS系统)
二噁英采样仪/二噁英采样器