简介
用小火焰点燃水平放置并暴露于倾斜的热辐射场中的铺地材料,测量火焰停止横向传播时刻的临界热通量,适用于地毯、木板、地板及地板喷涂材料等铺地材料。同时可测量燃烧过程中的烟密度。
标准
GB/T 11785:铺地材料的燃烧性能测定 辐射热源法
ISO 9239-1:Reaction to Fire Tests for Floorings – Part1:Determination of the Burning Behavior Using a Radiant Heat Source
ISO 9239-2: Reaction to Fire Tests for Floorings – Part2:Determination of Flame Spread at a Heat Flux Level of 25kW/㎡
ASTM E 648:Standard Test Method for Critical Radiant Heat Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
ASTM E 970:Standard Test Method for Critical Radiant Heat Flux of Exposed at Attic Floor Insulation Using a Raidant Heat Energy Source
NFPA 253: Standard Method of Test for Critical Radiant Heat Flux of Floor Covering Systems Using a Radiant Heat Energy Source
特征
19寸触控显示屏,内置测试软件使校准、测试程序更便捷;
箱体内壁由厚度13±1mm,密度650kg/m3的硅酸钙板组成;
试样及试样架两侧与箱壁间的平均间隙面积为0.23±0.03㎡;
辐射板尺寸300×450mm,与试样水平面夹角30°,温度可达900℃;
引燃火焰燃烧器由不锈钢管制成,水平方向平均分布19个0.7mm直径的孔,在水平向下60°平均分布16个0.7mm的孔;
烟道内排气流速达到2.5±0.2m/s;
辐射高温计测试范围480-530℃,距离辐射板1.4m,能感温辐射板上直径250mm的圆面;
燃烧器火焰高度60-120mm可调;
软件辅助进行校准程序,记录、绘制并判定热通量曲线符合性;
便携式热流计,自带冷却系统,无需额外循环冷却水;
配置光路测量装置,可测量烟密度;
DAQ数据采集自动记录测试数据;
型号 | FT-FRP-827 |
主体尺寸 | 长1400×宽500×高2000mm |
控制台尺寸 | 长600×宽750×高1600mm |
电源 | AC 220V,50/60Hz,20A |
重量 | 200kg |
说明书 | 可提供 |
排气 | 30-85m3/min |
配件 | 丙烷、甲烷 |
2016-12-28