It enables quantitation that is compliant with the ML set by the EU for mycotoxins in cereals. With exception of aflatoxin B1 the same method could be applied for analysis of baby food samples.
Mycotoxins are potentially toxic secondary metabolites produced by different species of fungi. The main relevant species occurring on cereals are Penicillium sp., Fusarium sp. and Aspergillus sp. The fungal contamination can either occur on the field or during storage. Estimations are given that approximately 25% of all crops are contaminated with mycotoxins. The type and amount of contamination varies with climate conditions. As the contamination can result in serious health issues,mycotoxin analysis is an important part of routine food control.1, 2
For cereals and baby food, the European Union (EU) legislation currently sets maximum levels (ML) for the following mycotoxins: deoxynivalenol, zearalenone, T-2
toxin, HT-2 toxin, fumonisin B1, fumonisin B2, aflatoxin B1, B2, G1, G2 and ochratoxin A.3-6 The European Food Safety Authority (EFSA) is continuously examining the occurrence and health risks of further mycotoxins. One of the main current topics of interest is the acetylated deoxynivalenol metabolites and deoxynivalenol-3 glucoside.7 For some mycotoxins, e.g. sterigmatocystin, which is related to aflatoxins, EFSA could not determine the risk due to lack of data.8
In our measurements, matrix effects were estimated by comparing the slope of the calibration curve in solvent and matrix (see Table 4). Even after dilution of extract,
most analytes showed medium to high matrix effects. The matrix effects in maize are generally higher than in wheat. Thus, for this approach a matrix matched calibration for quantitation is still highly recommended. The linearity was reviewed for solvent as well as for the two matrices. The values are summarized in Table 4 and show good
linearity (>0.99) for most analytes in solvent and matrix. The injection precision was determined by six replicate
injections of a standard in solvent, wheat and maize. The relative standard deviation (RSD) in % is summarized in Table 5.
高压离子色谱Inuvion快速测定自来水中的常见阴离子
高压离子色谱Inuvion快速测定生活饮用水中的亚氯酸 盐、溴酸盐、氯酸盐、二氯乙酸和三氯乙酸
Thermo Fisher Scientific iCAP TQe ICP-MS/MS测定土壤和沉积物多种元素
相关产品
赛默飞Inuvion离子色谱系统
TSQ 9610 三重四极杆 GC-MS/MS
赛默飞气相色谱仪Trace 1600
ISQ 7610™单四极杆 GC-MS
Vanquish Neo UHPLC 系统
赛默飞TSQ Quantis Plus 三重四极杆质谱仪
赛默飞TSQ Altis Plus 三重四极杆质谱仪
赛默飞TSQ Fortis Plus三重四极杆质谱仪
Orbitrap Exploris MX 质量检测器
Orbitrap IQ-X Tribrid 质谱仪
赛默飞三重四极杆 LC-MS质谱系统TSQ Altis(LC-QQQ)
Orbitrap Exploris GC 气质联用仪
Orbitrap Exploris GC 240
新一代Orbitrap Exploris 240质谱仪
Thermo Scientific™ Orbitrap Exploris 120
关注
拨打电话
留言咨询