供货周期: | 现货 |
品牌: | 珀金埃尔默 |
货号: | N6121022,N6502013,N6502014,N6502015,N6502016,N6502 |
?
产品名称:Glass Inlet Liners
仪器厂商:PerkinElmer/美国 珀金埃尔默
价格:面议
库存:是
Capillary Split/Splitless Injector Liners | |||||
Description | ID mm | OD mm | Length mm | Pkg | Part no. |
PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) – General purpose use, ideal for chlorinated pesticides analyses | 2 | 4 | 86.2 | 5 | N6502001 |
Split Glass Liner Siltek Deactivated Surface Liner (with wool) – Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken | 4 | 6.2 | 92.1 | 5 | N6121020 |
Split Glass Liner (with wool) – Universal liner for general purpose analyses | 4 | 6 | 92.1 | 5 | N6502009 |
Split Siltek Deactivated Glass Liner (with wool) – Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range | 4 | 6 | 92.1 | 5 | N6502010 |
Clarus Cup Split Glass Liner – Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean | 4 | 6 | 92.1 | 5 | N6502011 |
Clarus Cyclosplitter Glass Liner – Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections | 4 | 6 | 92.1 | 5 | N6502012 |
Uniliner Deactivated Glass Liner (with wool) – Universal liner or general purpose analyses | 4 | 6.2 | 92.1 | 5 | N6121022 |
Clarus Splitless Glass Liner – Low volume sample analyses, beneficial with headspace and purge/trap | 1 | 6.2 | 92.1 | 5 | N6502006 |
Quartz Liner for Splitless Operation (ships with instrument) –Standard injector liner | 2 | 6.2 | 92.1 | 1 | N6121002 |
Glass Liner for Splitless Operation – Universal liner for general purpose analyses | 2 | 6.2 | 92.1 | 1 | N6101372 |
Deactivated Glass Liner for Splitless Operation (with wool) – Good for analyses of trace samples | 2 | 6.2 | 92.1 | 5 | N6121021 |
Siltek Deactivated Liner (with wool) for Splitless Operation – Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken | 2 | 6.2 | 92.1 | 5 | N6502004 |
Quartz Liner for Split Operation – Good for large volume injection samples | 4 | 6.2 | 92.1 | 1 | N6121001 |
Glass Liner for Split Operation – Universal liner for general purpose analyses | 4 | 6.2 | 92.1 | 1 | N6101052 |
Siltek Deactivated Double Gooseneck Glass Liner (with wool) – Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems | 4 | 6.2 | 92.1 | 5 | N6502003 |
Cyclo Double Gooseneck Liner for Split Operation – Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean | 4 | 6.2 | 92.1 | 5 | N6502005 |
Zero Dilution Glass Outer Liner – Ideal for trace HS work. Use in conjunction with N1011446 | 2 | 6.3 | 90 | 1 | N1011445 |
Zero Dilution Glass Inner Liner – Ideal for trace HS work. Use in conjunction with N1011445 | 2 | 6.3 | 90 | 1 | N1011446 |
Programmed Temperature Split/Splitless (PSS) Injector Liners | |||||
Quartz Liner for Splitless operation (ships with instrument) – Excellent liner for low volume analyses | 1 | 4 | 86.2 | 1 | N6121006 |
NEW! Siltek Deactivated Glass PSS Liner – Used for low volume trace sample analyses | 1 | 4 | 86.2 | 5 | N6502000 |
Quartz Liner for Split operation (ships with instrument) – Approved PerkinElmer standard injector liner | 2 | 4 | 86.2 | 1 | N6121004 |
NEW! Siltek Deactivated Glass Liner for Split operation (with wool) – Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken | 2 | 4 | 86.2 | 5 | N6502001 |
NEW! Siltek Deactivated Glass Liner for Split operation – Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range | 2 | 4 | 86.2 | 5 | N6502002 |
Zero Dilution Outer Liner –Use in conjunction with N1011446 | 2.8 | 4 | 83 | 1 | N1011447 |
Zero Dilution Inner Liner –Use in conjunction with N1011447 | 2 | 73 | 1 | N1011446 | |
On-column Glass Liner | 2.4 | 4 | 86.2 | 1 | N6101539 |
Liner/Hour Glass for POC Injector | 2.4 | 4 | 19.05 | 1 | N6101703 |
Quartz Split Liner with Silanized Glass Wool | 2 | 4 | 86.2 | 1 | N6121008 |
Quartz Split Liner with Silanized Glass Wool | 2 | 4 | 86.2 | 5 | N6121009 |
Packed Column Injector Liners | |||||
Drilled Uniliner (hole on top) – Excellent liner for high sample recovery and linearity, recommended for aqueous injections. | 4 | 6.2 | 92.1 | 5 | N6121022 |
NEW! Drilled Uniliner (hole on bottom) – Recommended for analysis in which compounds of interest could be affected by a tailing solvent peak. Good for PPC equipped GCs | 4 | 6.2 | 92.1 | 5 | N6502013 |
NEW! Gooseneck Drilled Uniliner (hole on top) – Use for trace,active samples, high recovery and linearity | 4 | 6.2 | 92.1 | 5 | N6502014 |
NEW! Gooseneck Drilled Uniliner (hole on bottom) – Use for trace, active samples, high recovery and linearity | 4 | 6.2 | 92.1 | 5 | N6502015 |
NEW! Open Top Uniliner (with wool) – Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue | 4 | 6.2 | 92.1 | 5 | N6502016 |
NEW! Cyclo Uniliner – Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction | 4 | 6.2 | 92.1 | 5 | N6502017 |
Wide-Bore Column Glass Liner | 6 | 4 | 92.1 | 1 | N6101375 |
Wide-Bore Column On/Off Quartz Liner | 6 | 4 | 92.1 | 1 | N6121003 |
Colored Injector Liners | |||||
PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility | 2 | 4 | 86.2 | 5 | N9306232 |
Capillary splitless deactivated glass liners with deactivated wool. | 4 | 6.2 | 92.1 | 5 | N9306233 |
Capillary splitless deactivated glass liners with deactivated wool. | 4 | 6.2 | 92.1 | 1 | N9306234 |
Capillary splitless deactivated glass liners with deactivated wool. | 4 | 6.2 | 92.1 | 5 | N9306235 |
Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample. | 4 | 6.2 | 92.1 | 5 | N9306236 |
PSS Splitless deactivated glass liners with deactivated wool 5/pk. | 1.25 | 4 | 86.2 | 5 | N9306237 |
正相色谱柱 Inertsil 系列Inertsil 5020-06036/5020-19232/5020-19182/5020-19482
保护卡套色谱柱和附件
极性相色谱柱 07110043,07110045,07110031,07110032,07110033,07110145
其他制备HPLC 色谱柱
微粒型毛细管HPLC 色谱柱的种类
正相/SEC 色谱柱 Inertsil 系列
正相色谱柱 Inertsil 系列Inertsil
Brownlee色谱柱 N9303970,N9303971,N9303972,N9303973
Brownlee色谱柱 N9303911,N9303912,N9303913,N9303914,N9303915
Brownlee色谱柱 N9303916,N9303917,N9303918,N9303919,N9303920
Brownlee色谱柱 N9303921,N9303922,N9303852,N9303853,N9303854
Brownlee色谱柱 N9303974,N9303975,N9303995,N9303996
2.0 M Ammonium Acetate
Acclaim Surfactant Plus
AminoPac PA1 Guard Column
关注