供货周期: | 一周 |
品牌: | ohio valley |
货号: | 21026 |
产品特点:
分流出口捕集管
Split Vent Trap with 3 Cartridges, each
SKU: 21026
Categories: Gas Purifiers & Traps, Tools for Chromatography Tag: Split Vent Traps
● 高容量
● 易于更换
The split vent trap attaches to the GC?s split vent to absorb organics released during sample injection. The trap contains 1200 mg of activated charcoal from coconut shells, which is a very effective scrubber of organics. It will absorb hydrocarbons other than methane at room temperature. Since there is no good indicator of when the absorption capacity has been reached, monthly or bi-monthly replacement of the charcoal tubes is recommended, depending on the frequency of GC use. The split vent trap consists of glass absorbent tubes, 1/8″ end fittings and a clear plastic protective sleeve. The trap is approximately 6 3/8″ long including fittings.
安装:
The split vent trap is supplied assembled, with 1/8″ fittings at each end. Remove the plugs at both ends by unscrewing the nuts. Either end of the trap can be directly attached to the outlet tubing from your GC?s split vent, if it is 1/8″ in diameter. For other size outlet tubing, use an appropriate reducing union (not included), or change the outlet tubing to 1/8″ diameter. Use a wrench to tighten the fitting onto the split vent outlet tubing 3/4 turn past finger-tight. The exit end of the trap requires no tubing. The split vent trap is generally installed in a vertical position.
更换捕集管:
Replacement cartridges are supplied with plastic end caps to prevent air contaminants from depleting the charcoal. The split vent trap does not need to be removed from the GC to replace the cartridge. Simply unscrew the outer plastic tub from the large fitting on the inlet end, then remove the cartridge. Leave the rubber O-rings in place inside each large fitting. Remove the plastic end caps off the new cartridge, slide it into the outer plastic tube, then screw this back onto the first large fitting. Tighten only finger-tight, which will be about 1/4 to 1/2 turn past the first point of resistance. Do not over tighten.
Additional informationWeight 0.37 lbs Dimensions 0.37 x 0.37 x 0.37 in
相关产品
Shim-pack SBC-ODS | 228-17268-91
Trident LC 保护柱套,27472
Ultra 保护柱芯,910150210
VanGuard保护柱
Viva 保护柱芯,951050210
保护柱 - 由柱套、柱芯组成
保护柱芯
保护柱芯 | 1.50250.0001
油溶性SEC(GPC)色谱柱:常规分析
瑞士万通 保护柱 A4/5 | 6.1006.540
瑞士万通 PRP-X100 保护柱/4.0 | 6.1005.020
瑞士万通 保护分析柱A1 | 4.6 6.1005.340
瑞士万通 保护分析柱A16 | 6.1031.500
瑞士万通 保护分析柱A16 | 6.1031.510
瑞士万通 保护分析柱C4 | 6.1050.510