Dionex IonPac AS9-HC 阴离子交换柱



使用 Thermo Scientific? Dionex? IonPac? AS9-HC 中等容量碳酸盐淋洗液阴离子交换柱分析饮用水中的痕量溴酸盐。 Dionex IonPac AS9-HC 柱专为分析饮用水中的痕量溴酸盐设计,是美国 EPA 方法 300.1 和 317.0 的指定色谱柱。 然而,先进的高容量 Dionex IonPac AS23 碳酸盐淋洗液阴离子交换柱则推荐用于测定臭氧处理饮用水中卤氧化物和无机阴离子,如痕量溴酸盐。



描述

环境基质中的无机阴离子和卤氧化物分析

提供多种规格,实现应用灵活性


Dionex IonPac AS9-HC 阴离子交换柱

订货信息:

分析柱
IonPac AS9-HC Analytical Column (4 x 250 mm)051786
IonPac AS9-HC Analytical Column (2 x 250 mm)052244
Dionex IonPac AS9-HC Capillary Column (0.4 × 250 mm)082319
保护柱
IonPac AG9-HC Guard Column (4 x 50 mm)051791
IonPac AG9-HC Guard Column (2 x 50 mm)502248
Dionex IonPac AG9-HC Capillary Column (0.4 × 50 mm)088296




High-Capacity Column for the Analysis of Inorganic Anions and Oxyhalides Including Bromate

Specifically designed for trace bromate in drinking water, the Thermo Scientific? Dionex? IonPac? AS9-HC column is the specified column for U.S EPA Methods 300.1 and 317.0.

The Dionex IonPac AS9-HC column is a high-capacity carbonate eluent anion-exchange column with selectivity similar to the Dionex IonPac AS9-SC column. The Dionex IonPac AS9-HC column also supports the analysis of oxyhalides and inorganic anions, including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate. The Dionex IonPac AS9-HC column is specified in validated methods such as U.S. EPA Method 300.1 and 317.0 and meets or exceeds the performance requirements of these methods.

This column separates trace bromate in drinking water matrices using an isocratic carbonate eluent and a large-loop injection. The Dionex IonPac AS9-HC column also offers good retention of fluoride out of the water dip. The column’s high capacity (190 μeq for 4 × 250 mm column) increases retention time to approximately 22 min. Use the Thermo Scientific Dionex Anion Electrolytically Regenerating Suppressor (AERS 500) with the Dionex IonPac AS9-HC column.

The Dionex IonPac AS9-HC column is offered in three formats: standard bore (4 × 250 mm), microbore (2 × 250 mm), and capillary (0.4 × 250 mm). The capillary format is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption with helps reduce the operating costs.

Note: The Thermo Scientific Dionex IonPac AS23 column is the newest carbonate eluent column recommended for the analysis of oxyhalides including bromate.

 

Thermo Scientific Dionex IonPac AS9-HC Anion-Exchange Column  Specifications
DimensionsDionex IonPac AS9-HC Analytical Column:
2 × 250 and 4 × 250 mm  
Dionex IonPac AS9-HC Capillary Column:
0.4 × 250 mm
Dionex IonPac AG9-HC Guard Column:
2 × 50 mm and 4 × 50 mm
Dionex IonPac AG9-HC Capillary Guard Column:
0.4 × 50 mm
Mobile Phase CompatibilitypH 0–12; 0–100% HPLC solvents
Substrate CharacteristicsBead Diameter: 9.0 μm 
Pore Size: 2000 ? 
Cross-Linking (%DVB): 55%
Latex CharacteristicsFunctional Group: Alkyl/alkanol quaternary ammonium ion 
Latex Cross-Linking: 15% 
Latex Diameter: 90 nm 
Hydrophobicity: Medium-Low
Maximum Operating Pressure4000 psi
Capacity1.9 μeq (0.4 × 250 mm capillary column)
47.5 μeq (2 × 250 mm analytical column) 
190 μeq (4 × 250 mm analytical column)
0.06 μeq (0.4 × 50 mm capillary guard column)
1.5 μeq (2 × 50 mm guard column)
6 μeq (4 × 50 mm guard column)
Column ConstructionPEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.

Separation of inorganic anions and oxyhalides using the Dionex IonPac AS9-HC column.

 

Determination of trace bromate in drinking water using the Dionex IonPac AS9-HC column.

 

Analysis of wastewater for anions using the Dionex IonPac AS9-HC column.

 

 

Analysis of drinking water spiked with 5 μg/L bromate using the Dionex IonPac AS9-HC capillary column.

 

 

Fast analysis of inorganic anions and oxyhalides using the Dionex IonPac AS9-HC capillary column.

 

Analysis of spiked tap water using EPA Method 317.0.

 

Determination of trace-level DBP anions in spiked tap water using the Atlas? suppressor.

Product Data Sheets
IonPac AS9-SC and AS9-HC Anion-Exchange Columns Data Sheet
IonPac AS9-HC Analytical Column Manual
Application Notes
AN 149: Determination of Chlorite, Bromate, Bromide, and Chlorate in Drinking Water by Ion Chromatography with an On-Line-Generated Postcolumn Reagent for Sub-μg/L Bromate Analysis
AN 136: Determination of Inorganic Oxyhalide Disinfection Byproduct Anions and Bromide in Drinking Water Using Ion Chromatography with the Addition of a Postcolumn Reagent for Trace Bromate Analysis
AN 135: Determination of Inorganic Anions in Wastewater by Ion Chromatography
AN 85: Determination of Trace Anions in Organic Solvents
AN 81: Ion Chromatographic Determination of Oxyhalides and Bromide at Trace Level Concentrations in Drinking Water Using Direct Injection
Technical Notes
TN 46: Determination of Trace Anions in Concentrated Glycolic Acid
TN 45 Determination of Trace Anions in Hydrofluoric Acid, Ammonium Fluoride, and a Buffered Oxide Etchant


Dionex IonPac AS9-HC 阴离子交换柱信息由北京豫维科技有限公司为您提供,如您想了解更多关于Dionex IonPac AS9-HC 阴离子交换柱报价、型号、参数等信息, 欢迎来电或留言咨询。除供应Dionex IonPac AS9-HC 阴离子交换柱外,北京豫维科技有限公司还可为您提供其他等产品, 公司有专业的客户服务团队,是您值得信赖的合作伙伴。

相关产品

当前位置: 仪器信息网 北京豫维 耗材 Dionex IonPac AS9-HC 阴离子交换柱

关注

拨打电话

留言咨询