供货周期: | 现货 |
品牌: | 戴安 |
货号: | SP5482 |
New! The Thermo Scientific ProPac™ SCX column line has expanded to include the next generation ProPac SCX-20 column. This column provides unequalled high resolution of protein variants.
Please also see the Thermo Scientific MAbPac™ SCX-10 column, a strong cation-exchange column designed specifically for high-resolution, high-efficiency analysis of monoclonal antibodies (MAbs) and associated variants. This column is complimentary to the industry-leading ProPac WCX-10 column for monoclonal antibody variant analysis. The MAbPac SCX-10 offers an alternative selectivity and provides higher resolution and efficiency for variant analysis of most monoclonal antibody samples than the ProPac WCX-10 column.
ProPac SCX-10 and WCX-10 strong and weak cation-exchange columns are based on a nonporous core particle that results in high-efficiency peaks and high-resolution separations of protein variants. A hydrophilic layer prevents unwanted secondary interactions. A grafted cation-exchange surface provides pH-based selectivity control and fast mass transfer for high-efficiency separation and moderate capacity.
Characterization and quality control assessment of monoclonal antibodies and other proteins
Unequalled resolution
High-resolution separations with excellent sample recovery
Unmatched column-to-column and lot-to-lot reproducibility
Useful for characterization of related protein variants (e.g., deamidation and MAb lysine truncation variants)
Highly-efficient peaks with excellent sample recovery
Available in different dimensions and formats for flexibility in method development
The ProPac SCX-10 is a strong cation-exchange column with sulfonate functional groups, and the ProPac WCX-10 column has a carboxylate functional group. Both are based on 10 μm nonporous, polymeric beads and coated with a proprietary hydrophilic layer.
All ProPac columns are manufactured and tested under the strictest specifications, resulting in unmatched column-to-column and lot-to-lot reproducibility. These columns are available as lot-select packages containing three columns from a single lot or three columns from three different lots, to assist quality control scientists in method validation.
ProPac SCX-10 Strong Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications | |
---|---|
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating temperature | 60 °C Recommended operating temperature:<40 °C |
Typical operating conditions | UV detection at 1 mL/min Recommended flow rate: 1 mL/min |
Mobile phase compatibility | pH 2–12; 80% compatible with acetonitrile, acetone, methanol. Compatible with nonionic and zwitterionic detergents. Incompatible with cationic detergents. |
Resin composition | 10-μm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the sulfonate functional groups. |
Anion-exchange capacity | < 100 μg protein on-column, depending upon the protein (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
ProPac WCX-10 Weak Cation-Exchange Column for the High-Resolution Separation of Protein Isoforms Specifications | |
---|---|
Resin composition | 10-μm-diameter core bead (55% cross-linked) grafted with a pellicular layer to which are attached the carboxylate functional groups. |
Anion-exchange capacity | < 100 μg protein on-column, depending upon the protein (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Maximum operating pressure | 3000 psi (21 MPa) |
Maximum operating temperature | 60 °C Recommended operating temperature:<40 °C |
Typical operating conditions | UV detection at 1 mL/min Recommended flow rate: 1 mL/min |
Mobile phase compatibility | pH 2–12; 80% compatible with acetonitrile and acetone. Compatible with nonionic and zwitterionic detergents. Incompatible with cationic detergents. |
SCX Analytical Columns | |
---|---|
ProPac SCX-20 Analytical Column (4 x 250 mm) | 074628 |
ProPac SCX-10 Analytical Column (4 x 250 mm) | 054995 |
ProPac SCX-10 Analytical Column (2 x 250 mm) | 063456 |
ProPac SCX-10 Semi-Preparative Column (9 x 250 mm) | 063700 |
ProPac SCX-10 Semi-Preparative Column (22 x 250 mm) | SP5522 |
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (1 Lot of Resin) | SP5727 |
ProPac SCX-10 Lot Select Column Set (4 x 250 mm) (3 Lots of Resin) | SP5728 |
SCX Guard Columns | |
---|---|
ProPac SCX-20 Guard Column (4 x 50mm) | 074643 |
ProPac SCX-10G Guard Column (4 x 50 mm) | 079930 |
ProPac SCX-10G Guard Column (2 x 50 mm) | 063462 |
WCX Analytical Columns | |
---|---|
ProPac WCX-10HT Analytical Column (4x 50mm) | 074600 |
ProPac WCX-10 Analytical Column (4 x 100 mm) | SP5829 |
ProPac WCX-10 Analytical Column (4 x 150 mm) | SP6703 |
ProPac WCX-10 Analytical Column (4 x 250 mm) | 054993 |
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (1 Lot of Resin) | SP5512 |
ProPac WCX-10 Lot Select 3 Column Set (4 x 250 mm) (3 Lots of Resin) | SP5513 |
ProPac WCX-10 Analytical Column (2 x 250 mm) | 063472 |
ProPac WCX-10 Semi-Preparative Column (9 x 250 mm) | 063474 |
ProPac WCX-10 Semi-Preparative Column (22 x 250 mm) | SP5482 |
WCX Guard Columns | |
---|---|
ProPac WCX-10G Guard Column (2 x 50 mm) | 063480 |
ProPac WCX-10G Guard Column (4 x 50 mm) | 054994 |
相关产品
46200800赛默飞10ml移液器红色无菌准确度3.0%至0.6±
46200700赛默飞5ml电动移液器兼容吸头Finntip:5mL
46200600赛默飞1ml电动移液器蓝色无菌
46200500赛默飞300ul电动移液器兼容吸头Finntip:300,Flex300
46200400赛默飞电动移液器兼容吸头Finntip:Flex 200、250通用,200加长
46200300赛默飞电动单道移液器兼容吸头Finntip250通用,200加长
46200200赛默飞5至50μL电动移液器
46200100黄色电动可高温高压单道移液器
粉色无菌电动移液器赛默飞46200000
4620300 Finnpipette™ Novus 电子单通道移液器
4701070 F2单道可调移液器套装2-1000µl赛默飞
4700885赛默飞混色Finnpipette F2 GLP 套件
4700880赛默飞0.2-2 μL微量F2单道可调套装移液器
4700870赛默飞Finnpipette™ F2 良好实验室移液 (GLP) 套件
4662080赛默飞16道可调移液器适配1-10ul(微型管咀)
关注
拨打电话
留言咨询