供货周期: | 现货 |
品牌: | 戴安 |
货号: | 43054 |
Oligosaccharides released from therapeutic glycoproteins can differ in size, charge, branching, and linkage. Oligosaccharides with these features can be resolved using the CarboPac® PA100. It provides the flexibility to separate oligosaccharides into broad classes depending upon the degree of sialylation, while maintaining the resolution needed for routine analysis based on linkage isomerism. Coupled with pulsed amperometric detection, the PA100 supports detection at low-picomole levels.
Separation of closely related oligosaccharides, even isomers, at picomole levels
Separation of neutral and charged oligosaccharides in the same run
No sample derivatization required for detection
The CarboPac PA100 column is a high-resolution, strong anion-exchange column for enhanced chromatography of oligosaccharides.
The Carbohydrate Membrane Desalter can be used on-line prior to fraction collection.
CarboPac PA100 Column for Oligosaccharide Analysis Specifications | |
---|---|
Dimensions | CarboPac PA100 Analytical Column: 4 × 250 mm CarboPac PA100 Guard Column: 4 × 50 mm CarboPac PA100 Microbore Column: 2 × 250 mm CarboPac PA100 Microbore Guard Column: 2 × 50 mm CarboPac PA100 Semipreparative Column: 9 × 250 mm CarboPac PA100 Semipreparative Column: 22 × 250 mm |
Maximum operating pressure | 4000 psi (27.9 MPa) |
Temperature range | 4–60 °C Recommended operating temperature: ambient |
Typical operating conditions | 2400 psi at 1.0 mL/min (analytical and guard columns) Recommended flow rate: 1.0 mL/min |
Mobile phase compatibility | pH 0–14; 100% compatible with common organic solvents. Ionic form eluents: sodium acetate and sodium hydroxide only. |
Resin composition | 8.5-μm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linking) agglomerated with 275-nm MicroBead™ quaternary amine functionalized latex (6% cross-linked). |
Anion-exchange capacity | Approximately 90 μeq/column (4 × 250 mm analytical column) |
Column construction | PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Analytical Columns | |
---|---|
CarboPac PA100 Analytical Column (2 x 250 mm) | 057182 |
CarboPac PA100 Analytical Column (4 x 250 mm) | 043055 |
CarboPac PA100 Column (9 x 250 mm) | SP2089 |
CarboPac PA100 Column (22 x 250 mm) | SP2667 |
Guard Columns | |
---|---|
CarboPac PA100 Guard Column (2 x 50 mm) | 057183 |
CarboPac PA100 Guard Column (4 x 50 mm) | 043054 |
相关产品
奥立龙Fisherbrand FE 系列双液接pH电极S35932
奥立龙Fisherbrand FE 系列单液接pH电极S35931
奥立龙Fisherbrand FE 系列pH/ATC电极S35930
奥立龙Accumet XL系列仪表IQOQ文件IQOQ-XL
奥立龙Accumet AE 自动温度补偿探头(120mm)13-620-21
奥立龙Accumet AE 自动温度补偿探头 (90mm)13-620-22
奥立龙Accumet AE DJ 凝胶填充 pH电极13-620-299B
奥立龙Accumet AE SJ 凝胶填充 pH电极13-620-108B
奥立龙Accumet AE SJ pH/自动温度补偿电极13-620-AE6
奥立龙溶解氧膜套,6个/个13-637-DOM
奥立龙FISHER SCIENTIFIC USB 鼠标13-637-692
奥立龙打印纸,2卷装13-637-691
奥立龙ACCUMET AB XL打印机,100-240V13-637-690
奥立龙RS232 输出线, PC到打印机13-637-681
奥立龙电导率校正组件13-637-674
关注
拨打电话
留言咨询