PM2.5 Sampling Procedures
For PM2.5 sampling the following changes must be made to the filter holder:
Ensure that the multiple impactor adapter with the PM10 impactor (silver) is installed on top of the preseparator assembly, while the PM2.5 impactor (gold) is installed in the preseparator assembly.
Clean and lubricate the EMT (Easy Maintenance Target) every 5 sampling periods. The EMT may need to be cleaned more or less frequently depending on the degree of soiling.
After the sampler has been assembled, calibrated, verified to be in proper working order, and a filter loaded in the filter holder assembly, set flow rate adjustment in accordance with procedures as shown in the Operation Manual.
PM10 Sampling Procedures
For PM10 sampling, follow the steps below:
Ensure that the PM10 impactor (silver) is installed in the preseparator assembly. The multiple impactor adaptor is not needed, nor is the PM2.5 impactor (gold).
Clean and lubricate the EMT (Easy Maintenance Target) every 5 sampling periods. The EMT may need to be cleaned more or less frequently depending on the degree of soiling.
After the sampler has been assembled, calibrated, verified to be in proper working order, and a filter loaded in the filter holder assembly, set flow rate adjustment in accordance with procedures as shown in the Operation Manual.
TSP Sampling Procedures
For TSP sampling, the following changes must be made to the filter holder:
Remove the impactor(s) from the preseparator assembly and multiple impactor adapter; remove the adapter.
Clean the cap and preseparator assembly every 5 sampling periods, or more frequently if soiling is observed.
After the sampler has been assembled, calibrated, verified to be in proper working order, and a filter loaded in the filter holder assembly, set flow rate adjustment in accordance with procedures as shown in the Operation Manual.
Follow all other procedures in the Operation Manual, noting that TSP is being sampled.
Pump | ||
• | Double-diaphragm with laminar flow valve technology | |
• | Rated for 10,000 hours continuous operation | |
• | Ironless core motor with precious metal commutation | |
• | Flow range 0-10 LPM | |
Physical |
||
• | Polypropylene copolymer weatherproof sampler case | |
• | Dimensions: 10" x 12" x 7" | |
• | Weight: less than 10 lbs. fully configured | |
• | All in one transport case | |
• | Dimensions: 19.75" x 12" x 18" | |
• | Weight: less than 40 lbs. with all accessories | |
Timer |
||
• | Programmable 7-day timer with battery backup | |
• | Up to six sample periods per day | |
Pre-separator/Cassette Filter Holder Assembly | ||
• | Non-directional louvered inlet design | |
• | Easily removed for cleaning | |
• | Standard 47mm filter holder | |
• | Nominal 10 micron or 2.5 micron "cut-point" at 5 liters/minute sample rate | |
Electronics |
||
• | Constant flow control circuit | |
• | AC or DC operation | |
• | Variable flow adjustment | |
• | Elapsed time totalizer | |
• | Low battery indicator and shut-off | |
• | Low flow rate indicator and shutoff | |
Battery Pack | ||
• | Litium Ion batteries | |
• | 14.8V / 118 Watt Hours | |
• | 1.2 amp external battery charger | |
• | Full recharge in less than 6 hours |
Troubleshooting 故障排除 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
This section identifies common problems and the action necessary to correct them. | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Impactor Grease
The EMT (Easy Maintenance Impactor) should be cleaned and re-greased after every fifth run or more often if heavy soiling is observed. Airmetrics offers a 60gm tube of Glisseal Ht impactor grease.
Tedlar Bags
Original MiniVol™ samplers with gas ability feature six liter Tedlar bags in their collection canisters. Manufactured at Airmetrics, the bags can become damaged during repeated sampling use and may need replacement.
Filters
For particulate sampling, the MiniVol™ uses 47mm filters to collect particulate matter. Filters should be weighed pre- and post-exposure with a microbalance accurate to one microgram. Airmetrics offers the following types of filters:
To complement use of the MiniVol™ samplers, Airmetrics also offers filter weighing services.
Petrislides
Petrislides, plastic cassettes for shipping and storage of filters, are offered by Airmetrics in conjunction with the above filters.
Telescoping Hoisting Pole for Lifting Samplers
This pole allows the user to lift the sampler from the ground to its sampling site, up to 10 feet above ground. Siting the sampler can thus occur without using a ladder.
Tripod Assembly for Remote Locations
The tripod assembly allows the user to site the sampler in remote areas or on roof tops where no other mounting equipment exists.
Sampler Features
The Standard PM-2.5 MiniVol™ TAS includes:
Calibration Services
Airmetrics also offers Calibration Services for purchased MiniVols, FRM orifices, and the MiniFlow orifice (used to calibrate the MiniVol™). Airmetrics can also calibrate other flow auditing devices. All calibrated equipment comes with a calibration curve traceable to NIST. Contact Airmetrics for pricing.
Filter Weighing Services
In addition to supplying consumables and accessories for sampler use, Airmetrics offers a 47mm Filter Weighing Service to complement use of the MiniVol™ TAS and other types of air sampling equipment. We carry three types of filters (Fiber Film, Pure Quartz, and Pure Teflon; others may be special ordered), Contact Airmetrics for pricing.
Calibration and Auditing Procedures
Before a monitoring program is undertaken, all sampling and analysis equipment must be properly calibrated. Careful, accurate calibrations of sampling instrumentation and associated equipment provide the backbone for any monitoring network. Performing periodic audits is a way to ensure the integrity and assess the accuracy of sampling data.
The following presents calibration and auditing procedures specific to the MiniVol sampler, which is designed to operate at an actual total flow of 5.0 liters per minute (L/min), and the MiniFlo transfer standard, calibrated over the appropriate flow range.
Field Calibration Kits相关产品
510M气体流量校准器
510L/520L/530+L流量校准器
510H/520H/530+H BIOS气体流量计
Defender 520L美国BIOS公司低流量校准器
520L/520H/530L/530M/530H BIOS气体流量计空气站用
BIOS 510L/510H数字式采样器流量校准器
流量校准器
530+L流量校正器
Mesalabs 510M/520M/ 530+M BIOS气体流量计
电子皂膜流量计 M-30
YD-34G气体应急检测箱
突发有毒气体检测箱
YD-20气体快速检测仪/气体应急检测仪/气体应急检测箱
YD-40G化学物质泄漏应急检测箱
YD-5突发性事故气体快速检测箱
关注
拨打电话
留言咨询