GlycanPac AXR-1 多糖分析柱 088136
GlycanPac AXR-1 多糖分析柱Thermo Scientific GlycanPac AXR-1列是由电荷,异构和大小聚糖的同时分离一个高性能,二氧化硅基HPLC柱。它是专为生物重要聚糖提供独特的选择性业界领先的分辨率,无论是标或本机,或者使用荧光和/或质谱(MS)检测。GlycanPac AXR-1 多糖分析柱订货信息:分析柱GlycanPac AXR-1, Analytical, 1.9μm, 2.1x150mm088136GlycanPac AXR-1, Analytical, 1.9μm, 2.1x250mm088135GlycanPac AXR-1, Analytical, 3.0μm, 2.1x150mm088251GlycanPac AXR-1, Analytical, 3.0μm, 3.0x150mm088252GlycanPac AXR-1, Analytical, 3.0μm, 4.6 x150mm088255保护柱GlycanPac AXR-1, Guard, 3.0μm, 2.1 x10mm,2EA088258GlycanPac AXR-1, Guard, 3.0μm, 3.0 x10mm,2EA088259GlycanPac AXR-1, Guard, 3.0μm, 4.6 x10mm,2EA088260Acclaim SST Guard Cartridge Holder V-2069580Acclaim Guard Kit (Holder and coupler) V-2069707Guard to Analytical Column Coupler V-2074188GlycanPac AXR-1 Columns for the High-Resolution Separation and Analysis of GlycansThe Thermo Scientific™ GlycanPac™ AXR-1 column is a high-performance, silica-based HPLC column for the simultaneous separation of glycans by charge, isomerism, and size. It is designed to provide industry-leading resolution with unique selectivities for biologically important glycans, either labeled or native, using either fluorescence and/or mass spectrometry (MS) detection.Features:? Unique glycan selectivity based on charge, branch/linkage isomerism, and size? Exceptional resolution for either native or derivatized glycans? Utility for both high-resolution glycan structural characterization and glycan quantification? Compatibility with both MS and fluorescence detection methods? Reliable column performance? Available in HPLC (3 μm) and UHPLC (1.9 μm) formats.The GlycanPac AXR-1 column, based on innovative, mixed-mode surface chemistry, combines both weak anion-exchange (WAX) and reversed-phase interaction mechanisms to produce exceptional glycan selectivity and industry-leading resolution. The WAX functionality provides retention of negatively charged glycans that elute in order of increasing charge, and the reversed-phase mode facilitates resolution of glycans of the same charge according to their isomerism and size. These attributes produce unparalleled glycan separations. The GlycanPac AXR-1 column is designed for HPLC and UHPLC methods using either fluorescence or MS detection, and uses volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile, presenting the eluting glycans ready for introduction into MS instruments.GlycanPac AXR-1 columns are based on high-purity and spherical silica substrates in both 1.9 and 3 μm sizes for UHPLC and standard HPLC applications, respectively. GlycanPac AXR-1 columns are available in various dimensions for applications with different resolutions, throughput, and instrument requirements.Analytical ColumnsGlycanPac AXR-1, Analytical, 1.9μm, 2.1x150mm088136GlycanPac AXR-1, Analytical, 1.9μm, 2.1x250mm088135GlycanPac AXR-1, Analytical, 3.0μm, 2.1x150mm088251GlycanPac AXR-1, Analytical, 3.0μm, 3.0x150mm088252GlycanPac AXR-1, Analytical, 3.0μm, 4.6 x150mm088255Guard ColumnsGlycanPac AXR-1, Guard, 3.0μm, 2.1 x10mm,2EA088258GlycanPac AXR-1, Guard, 3.0μm, 3.0 x10mm,2EA088259GlycanPac AXR-1, Guard, 3.0μm, 4.6 x10mm,2EA088260Acclaim SST Guard Cartridge Holder V-2069580Acclaim Guard Kit (Holder and coupler) V-2069707Guard to Analytical Column Coupler V-2074188DataSheetGlycanPac AXR-1 Columns For High-Resolution Glycan AnalysisBrochuresThermo Scientific BioLC ColumnsManualsThermo Scientific GlycanPac AXR-1 Columns Product ManualGLYCANPAC AXR-1 COLUMN Quick StartPostersAn Ultra High Resolution Glycan Column for Isomeric Separation and the Structural Identification of Labeled N-Glycans from Proteins Including AntibodiesApplicationsAN: 20910 Separation of 2AA-Labeled N-Linked Glycans from Glycoproteins on a High-Resolution Mixed-Mode ColumnAN 20909: Separation of 2AA-Labeled N-Linked Glycans from Human IgG on a High-Resolution Mixed-Mode ColumnAN 20908: Separation of 2AB-Labeled N-Linked Glycans from Bovine Fetuin on a Novel Ultra High Resolution Mixed-Mode ColumnGlycanPac AXR-1 Column SpecificationsColumn Dimensions1.9 μm: 2.1 × 250mm, 2.1 × 150mm3 μm: 4.6 × 150mm, 3.0 × 150mm, 2.1 × 150mmParticle SizeSpherical 1.9 μm, 3 μm particlesSubstrateHigh-purity, Porous, Spherical SilicaSurface Area220 m2/gPore size175 ?Functional GroupWAX and RP Mixed-ModeRecommended Flow Rate Range:1.9 μm: 0.2 to 0.4 mL/min. for: all 2.1 mm columns3 μm: 0.8 to 1.2 ml/min for 4.6 × 150 mm 0.3 to 0.6 ml/min for 3.0 × 150 mm 0.1 to 0.3 ml/min. for 2.1 × 150 mmPressure Limit1.9 μm: 10,000 psi for 2.1 ×150mm 15,000 psi for 2.1 × 250mm3 μm: 6,000 psi for all 3 μm columnsTemperature Range:Ambient to 60 oCpH Range2.0 - 8.0