当前位置: 仪器信息网 > 行业主题 > >

促生长抑制素

仪器信息网促生长抑制素专题为您提供2024年最新促生长抑制素价格报价、厂家品牌的相关信息, 包括促生长抑制素参数、型号等,不管是国产,还是进口品牌的促生长抑制素您都可以在这里找到。 除此之外,仪器信息网还免费为您整合促生长抑制素相关的耗材配件、试剂标物,还有促生长抑制素相关的最新资讯、资料,以及促生长抑制素相关的解决方案。

促生长抑制素相关的耗材

  • 088666赛默飞抑制器用于离子色谱中的电解再生抑制
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific&trade Dionex&trade DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC&trade ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific&trade Dionex&trade ERS&trade 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For use with 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm)CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM)088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • 088666赛默飞抑制器用于离子色谱中的电解再生抑制
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific&trade Dionex&trade DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC&trade ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific&trade Dionex&trade ERS&trade 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For use with 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm)CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM)088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • Dionex SCC-10抑制电流控制器 074053
    Dionex SCC-10抑制电流控制器提高抑制寿命,同时降低噪音传统离子色谱法(IC)系统的只有四个电解抑制当前设置。 Thermo Scientific戴安SCC-10抑制电流控制器提供了一个选择12目前的水平,所以你可以选择适合您的IC应用的最佳操作条件。Dionex SCC-10抑制电流控制器订货信息:SCC-10 Suppressor Current Controller074053The SCC-10 Suppressor Current Controller is an external adapter designed for use with legacy instruments that offer only four settings for electrolytic suppressor current. This limitation prevents selection of the optimal operating conditions and suppressor current settings required for many IC (ion chromatography) applications. The SCC-10 output current can be set in 12 discrete steps from 10 to 250 mA, thus increasing suppressor lifetime while simultaneously reducing noise.The SCC-10 connects between the suppressor power supply for the IC system and the suppressor. Because the SCC-10 is powered from the existing suppressor power supply, it is not necessary to change the system configuration in the control software to support the SCC-10.The SCC-10 can be operated with the following legacy systems from Dionex:DX-120 Ion ChromatographDX-320 and DX-320J Ion ChromatographsDX-500 Ion Chromatography SystemDX-600 Ion Chromatography SystemDX-800 Process AnalyzerThe SCC-10 is compatible with the SRS 300 series of suppressors it is not compatible with the CMD, SRN, Atlas, or CES 300 series of suppressors.ManualsSCC-10 Suppressor Current Controller Installation Instructions
  • Dionex Atlas 电解抑制器 056116
    Dionex Atlas 电解抑制器为你的离子分离,尤其是在使用时,碳酸洗脱液,用的Thermo Scientific 戴安 AES Atlas电解抑制器更高的灵敏度和更低的噪音。你不会有混合再生剂 这抑制依赖于电解自动,连续再生。Dionex Atlas 电解抑制器订货信息:Anion Atlas Electrolytic Suppressor056116Cation Atlas Electrolytic Suppressor056118 Low Noise Electrolytically Regenerated Suppressor for Use with IC EluentsThe Thermo Scientific Dionex Atlas™ Electrolytic Suppressor (AES™ ) is a continuous electrolytically-regenerated suppressor based on the MonoDisc™ and AutoSuppression™ products. The unique design of the Dionex AES suppressor enables very fast startup times and an extremely low noise level, particularly for carbonate eluents. The benefits of the Dionex AES suppressor include: High performance and very low noise for carbonate eluentsLow background conductivity, and excellent baseline stabilityEasy to use maintenance-free operationFast startup and equilibrationWill suppress eluents up to 25 μeq/minThe MonoDisc suppression bed of the Dionex AES is composed of ion-exchange monolith and flow distribution disks. This configuration facilitates efficient exchange of the eluent counter ions for regenerant ions, resulting in eluent suppression and analyte response enhancement. Atlas Electrolytic Suppressors SpecificationsAAESPhysical SpecificationsDimensions (l × w × d)4.9 × 4.4 × 10.2 cm (1.9 × 1.8 × 4.0 in.)Weight120 g (0.3 lb)Void volume35 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure20–100 psiMaximum Eluent Flow Rate3 mL/minEluent Solvent Restrictions20% solvents (no solvents)Maximum Regenerant EWM3 Flow Rate5 mL/minModes of Operation SupportedRecycle and external waterMaximum Current150 mACAESPhysical SpecificationsDimensions (l × w × d)4.9 × 4.4 × 10.2 cm (1.9 × 1.8 × 4.0 in.)Weight120 g (0.3 lb)Void volume35 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure20–100 psiMaximum Eluent Flow Rate3 mL/minEluent Solvent Restrictions20% solvents (no solvents)Maximum Regenerant EWM3 Flow Rate5 mL/minModes of Operation SupportedRecycle and external waterMaximum Current150 mA1When installed outside the heated column enclosure, all suppressors can support applications up to 60 ?C.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = external water mode for eluents containing 40% solvent, use the chemical regeneration mode.Product Data SheetsRFIC Eluent Suppressors for Ion Chromatography Data SheetThermo Scientific Dionex Eluent Suppressors for Ion Chromatography
  • Dionex CRS 500 化学再生抑制器 085090
    Dionex CRS 500 化学再生抑制器高容量,溶剂兼容,化学,再生的抑制Thermo Scienfitic 戴安CRS500抑制器是化学再生的抑制,因此具有非常低的噪声和快速的启动时间。随着新的化学位移再生(DCR)套件,这款经典抑制器提供更方便的操作。该戴安CRS 500抑制优势包括:高容量,能够处理样品复杂基质溶剂兼容设计非常低的信号与噪声和优异的基线稳定性低方法检测限快速启动和平衡使用方便,免维护的DCR套件操作对改进的性能提高峰值效率,特别是当加上4微米基于柱改进的热稳定性,以消除因损坏安装故障装运期间,处理和操作的戴安CRS 500抑制器具有高容量,并且可以与所有热Scienfitic戴安离子交换柱中使用。对于最低噪声和最长寿命,戴安CRS 500抑制器建议使用含HPLC溶剂洗脱液阴离子和阳离子分离。该戴安CRS 500抑制在这两个2 - 4毫米格式提供 3毫米列应该有2mM抑制器使用。该戴安CRS 500抑制产生噪声最低,因为它使用非电解化学再生。低噪音转化为更低的方法检出限。Dionex CRS 500 化学再生抑制器订货信息:ACRS 500 Suppressor 4 mm085090ACRS 500 Suppressor 2 mm085091CCRS 500 Suppressor 4 mm085092CCRS 500 Suppressor 2 mm085093High-Capacity, Solvent-Compatible, Chemically-Regenerated SuppressorThe Thermo Scienfitic™ Dionex™ CRS™ 500 suppressor is a chemically-regenerated suppressor and therefore has very low noise and quick startup time. With the new Displacement Chemical Regeneration (DCR) Kit, this classic suppressor provides easier operation. The Dionex CRS 500 suppressor advantages include:High-capacity and solvent-compatible design capable of handling samples with complex matricesVery low signal-to-noise and excellent baseline stabilityLow method detection limitsFast start-up and equilibrationEasy to use, maintenance-free operation with the DCR kitImproved peak efficiency for improved performance, particularly when coupled with 4 μm based columnsImproved thermal stability to eliminate installation failures due to damage during shipment, handling, and operationThe Dionex CRS 500 suppressor has high capacity and can be used with all Thermo Scienfitic Dionex ion-exchange columns. For lowest noise and longest life, the Dionex CRS 500 suppressor is recommended for anion and cation separations using eluents containing HPLC solvents. The Dionex CRS 500 suppressor is available in both 2- and 4 mm formats 3 mm columns should be used with 2 mm suppressors.The Dionex CRS 500 suppressor produces the lowest noise because it uses non-electrolytic chemical regeneration. Low noise levels translate into lower method detection limits.Chemically Regenerated Suppressor (CRS 500) SpecificationsACRS 500Physical SpecificationsDimensions (l × w × d)14.0 × 4.5 × 4.8 cm (5.5 × 1.8 × 1.9 in.)Weight370 g (0.82 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure30-100 psiMaximum Eluent Flow Rate3 mL/min (4 mm)0.75 mL/min (2 mm)Eluent Solvent Restrictions2100% solvent compatibleMaximum Regenerant EWM3 Flow Rate10 mL/min (4 mm)5 mL/min (2 mm)Modes of Operation SupportedChemical, DCR ModeMaximum Currentn/aCCRS 500Physical SpecificationsDimensions (l × w × d)14.0 × 4.5 × 4.8 cm (5.5 × 1.8 × 1.9 in.)Weight370 g (0.82 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure30-100 psiMaximum Eluent Flow Rate3 mL/min (4 mm)0.75 mL/min (2 mm)Eluent Solvent Restrictions2100% solvent compatibleMaximum Regenerant EWM3 Flow Rate10 mL/min (4 mm)5 mL/min (2 mm)Modes of Operation SupportedChemical, DCR ModeMaximum Currentn/a1When installed outside the heated column enclosure, all suppressors can support applications up to 60 ?C.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = external water mode for eluents containing 40% solvent, use the chemical regeneration mode. Product Data SheetsRFIC Eluent Suppressors for Ion Chromatography Data SheetThermo Scientific Dionex Eluent Suppressors for Ion ChromatographyManualsDionex CRS 500 Suppressor Product Manual
  • 瑞士万通 IC双抑制器的抑制池 | 6.2838.000
    IC双抑制器的抑制池IC Dual Suppressor Cell订货号: 6.2838.000828双抑制器的备用池
  • KBWF/有湿度控制的植物生长箱
    热烈祝贺北京美同达科技有限公司成为美国VWR公司北方区授权总代理!即日起全线销售VWR International产品。更多新品优惠促销!详细请致致电010-52457812/52457811/88482632! KBWF 系列 &mdash &mdash 有湿度控制的植物生长箱 拥有对光照条件和湿度的精确模拟,适用于广泛的应用。 性能特点: &bull 带有DCT® 直冷系统的电子控制式APT.line® 内腔预热技术 &bull 温度范围(无湿度和光照):-5℃至100℃ &bull 温度范围(有湿度和光照):20℃至90℃ &bull MCS 控制器,控制温度、湿度和光照。有25 个存储程序,每个程序有100 节,最大500 个程序段,用于为白天/ 夜间循环编程 &bull 门内有日光灯管的光照系统;KBWF 240 &ndash 10 只灯 × 18 瓦KBWF 720 &ndash 10 只灯 × 36 瓦 &bull 电子控制式加湿和除湿系统,电极加湿,使用自来水;采用SPH 传感器技术的电容湿度传感器 &bull 独立的可调温度安全装置,3.1 级(DIN 12880)带有可视和声音温度报警器 &bull 接入口:口径为Ø 30 毫米 &bull RS 422 接口,用于通讯软件APT-COM® 数据控制系统 &bull 选项:根据光强和实际用途,可选择不同光源&mdash &mdash 日光灯、生长灯、Arabidopsis( 拟南芥) 灯。 Description Electrical Volume Exterior Dimensions Interior Dimensions Temperature Accuracy Temperature Range WeightSupplier No. VWR Catalog Number KBW 720 Model 230V, 50/60Hz, 2000W 700 L (24.7 cu. ft.) 123.4W x 86.7D x 181.6H cm (49 x 343/32 x 711/2") 100W x 60D x 116.8H cm (393/8 x 235/8 x 46") ± 0.5° at 25° C &ndash 10 to 60° C (14 to 140° F), 30 to 60° C (86 to 140° F) with Humidity and Illumination 262 kg (577.6 lbs.) 9020-0130 89038-320 KBWF 240 Model 230V, 50/60Hz, 2420W 240 L (8.5 cu. ft.) 103.4W x 74.6D x 114.2H cm (409/16 x 2913/32 x 45") 80W x 50D x 60H cm (311/2 x 1911/16 x 2319/32") ± 0.4° at 37° C &ndash 5 to 100° C (23 to 212° F), 20 to 90° C (68 to 194° F) with Humidity and Illumination 184 kg (405.6 lbs.) 9020-0166 80079-080KBWF 720 Model 230V, 50/60Hz, 2950W 700 L (24.7 cu. ft.) 123.4W x 86.7D x 181.6H cm (49 x 343/32 x 711/2") 100W x 60D x 120H cm (393/8 x 235/8 x 471/4") ± 0.4° at 37° C &ndash 5 to 100° C (23 to 212° F), 20 to 90° C (68 to 194° F) with Humidity and Illumination 345 kg (760.6 lbs.) 9020-0173 80079-078
  • Dionex SRS 300 再生抑制器 064554 | 064556
    2013年5月8日,戴安推出了Thermo Scientific Dionex ERS 500 系列电解再生抑制器,与此同时开始停产Thermo Scientific Dionex SRS 300 系列自再生抑制器。SRS 300 抑制器的订单将自动被对应的 ERS500 抑制器取代。受影响产品的产品号见本通知附表。Dionex ERS 500 抑制器是直接替换 Dionex SRS 300 抑制器的换代产品;与 SRS300 抑制器相比,其结构与功能并没有变化。Dionex ERS 500 抑制器的主要优势在于:更好的抑制器性能提供了更高的最佳效率,尤其是当该抑制器与4μm填料柱一起使用时;更高的柱压耐受能力,能适用于更多的检测器联用技术;更好的热稳定性,消除了因运输、处理、操作过程导致的安装故障;完全免试剂电解再生,不需要额外的流路就可轻松实现良好的抑制重现性。停产的 Dionex SRS 300 Suppressors 换代的 Dionex ERS 500 Suppressors 旧 P/N 旧名称新 P/N 新名称064554 ASRS 300 (4 mm) 082540 AERS 500 (4 mm) 064555 ASRS 300 (2 mm) 082541 AERS 500 (2 mm) 064556 CSRS 300 (4 mm) 082542 CERS 500 (4 mm) 064557 CSRS 300 (2 mm) 082543 CERS 500 (2 mm)戴安 SRS 300 离子色谱 再生抑制器 High-Capacity Electrolytically-Regenerated Suppressor for Use with IC EluentsThe SRS 300 serves virtually all analytical scale1 ion chromatography applications for both anions and cations. For anions, the preferred eluent is hydroxide. With RFIC systems, the sample is determined using conductivity detection in the lowest possible background of high-purity water. AutoSuppression means ease of use you don&rsquo t need to make regenerant because the suppressor is constantly regenerated by the continuous electrolysis of water. The SRS 300 offers: Low background noise levels Fast startup equilibration times Trace anion and cation determinations Compatibility with mass spectrometry detection Compatibility with all Dionex ICS and DX chromatography modules2 A three-fold increase in backpressure tolerance compared to previous generations The SRS 300 delivers low backgrounds and low noise levels for the full range of Dionex ion-exchange IonPac columns and eluents, even under high-concentration gradient conditions. When combined with the revolutionary Eluent Generator, The SRS 300 delivers truly automated, minimal-maintenance Reagent Free Ion Chromatography (RFIC).1For capillary scale ion-chromatography applications use the Capillary Electrolytic Suppressor (CES 300).2Chemical suppression mode only with the ICS-90 and ICS-900 systems. Older systems may require the RFC-10 or RFC-30 controller.订货信息: Anion Self-Regenerating Suppressor ASRS 300 4 mm,停产,新货号 082540 旧货号 064554 Anion Self-Regenerating Suppressor ASRS 300 2 mm,停产,新货号 082541旧货号 064555 Cation Self-Regenerating Suppressor CSRS 300 4 mm,停产,新货号 082542旧货号 064556 Cation Self-Regenerating Suppressor CSRS 300 2 mm,停产,新货号 082540旧货号 064557 Self-Regenerating Suppressor (SRS 300) SpecificationsASRS 300Physical Specifications Dimensions (l x w x d) 16.8 x 4.5 x 5.2 cm (6.6 x 1.8 x 2.1 in.) Weight 630 g (1.4 lb) Void volume 4 mm: 50 uL 2 mm: 15 uLChemical Specifications Temperature Range1 15~35 ℃ Recommended Backpressure 30~40 psi Maximum Eluent Flow Rate 3 mL/min (4 mm) 1 mL/min (2 mm) Eluent Solvent Restrictions2 40% solvents in EWM3 Maximum Regenerant EWM3 Flow Rate 5 mL/min (4 mm) 2 mL/min (2 mm) Modes of Operation Supported Recycle, EWM3, chemical (recycle recommended)4 Maximum Current 300 mA for 4 mm, 100 mA for 2 mm CSRS 300Physical Specifications Dimensions (l x w x d) 16.8 x 4.5 x 5.2 cm (6.6 x1.8 x 2.1 in.) Weight 630 g (1.4 lb) Void volume 4 mm: 50 uL 2 mm: 15 uLChemical Specifications Temperature Range1 15~40 ℃ Recommended Backpressure 30~40 psi Maximum Eluent Flow Rate 3 mL/min (4 mm) 0.75 mL/min (2 mm) Eluent Solvent Restrictions2 40% solvents in EWM3 Maximum Regenerant EWM3 Flow Rate 5 mL/min (4 mm) 2 mL/min (2 mm) Modes of Operation Supported Recycle, EWM3, chemical (recycle recommended)4 Maximum Current 300 mA for 4 mm, 100 mA for 2 mm1When installed outside the heated column enclosure, all suppressors can support applications up to 60 ?C.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = external water mode for eluents containing 40% solvent, use the chemical regeneration mode.4Recycle recommended for aqueous applications without solvent.
  • Dione ERS 500 电解再生抑制器82540
    该高容量抑制器几乎支持所有分析型 的 IC 应用,可用于阴离子和阳离子分析,提供 2mm 和 4mm 两种规格。 Dionex ERS 500 抑制器在标准孔 (4 mm) 和微孔 (2 mm) 规格下适用于碳酸盐(仅等度)、氢氧化物、甲基磺酸或硫酸淋洗液的等度或梯度应用。 下一代抑制器——专为 IC 应用新需求而造 由于其具有较高的反压耐受性(在高达 900 psi 的情况下无泄漏,在高达 200 psi 时进行操作),提高了联用检测技术的兼容性,特别是质谱仪 较高的温度耐受性(在运输和储存中高达 80°C,操作时为 40°C) 凭借其平面的填充床抑制槽,无电流操作后,无需试剂完全电解再生即可轻松恢复 低峰扩散保持 4μm 色谱柱的峰形效率在无需化学再生的情况下重新启动之后,其高抑制容量可立即产生稳定的峰面积值 低噪音特性使抑制器适用于痕量分析 为更可靠定量提高灵敏度 与 Thermo Scientific™ Dionex™ CRD 300 碳酸盐去除装置配合使用时,Dionex ERS 500 抑制器在碳酸盐淋洗液条件下,能够降低背景电导和噪音、增强分析物响应和检测灵敏度,从而提高定量的可靠性。 对实现 Reagent-Free™ IC (RFIC™ ) 操作十分重要 无需试剂的完全再生 Dionex ERS 500 抑制器可直接替代 Thermo Scientific™ Dionex™ SRS™ 300自再生抑制器。 产品规格 - Search Display Family Umbrella Brand Thermo Scientific™ 适用于 Modes of Operation Supported: -Recycle: Recommended for aqueous applications without solvent. -EWM: (External Water Mode) for eluents containing 40% solvent, use the chemical regeneration mode.-MPIC:( Mobile Phase Ion Chromatography) or ion-pairing 直径 4.8cm (1.9 in.) 流速 Maximum Eluent Flow Rate: 3mL/min 压力 Recommended Backpressure: 30-60 psi 溶剂 Less than 40% solvents in EWM External Water Mode Solvents for anion eluents include methanol. 长度(公制) 12.1cm (4.25 in.) 重量(英制) 0.65 lb 重量(公制) 295g 宽度(公制) 4.5cm (1.8 in.) 安培数 Maximum Current: 500 mA 物品描述 Dionex™ AERS™ 500 Anion Electrolytically Regenerated Suppressor (4mm) 温度范围 Operational Temperature Range: 15–40°C When installed outside the heated column enclosure, suppressors can support applications up to 60°C. Shipping Temperature Range: 0–70 °C Short-term only do not store or operate suppressors above 40 °C for extended lengths of time. 孔隙体积 Less than 50μL 描述 Dionex™ AERS™ 500 Anion Electrolytically Regenerated Suppressor (4mm)
  • Dionex SRD-10抑制再生剂检测器 074395
    Dionex SRD-10抑制再生剂检测器保护您的抑制器和使用外部水或化学再生模式下,尽一切运行计数。 Thermo Scientific戴安SRD-10抑制再生剂检测器,如果抑制再生流动停止或减缓,防止对抑制或浪费的离子色谱法(IC)运行损坏自动禁用洗脱液泵。Dionex SRD-10抑制再生剂检测器订货信息:SRD-10 Suppressor Regenerant Detector074395The SRD-10 Suppressor Regenerant Detector is a stand-alone device that monitors liquid flow to a suppressor. If the flow is restricted or stops, the SRD-10 automatically disables the eluent pump via a TTL command, thus preventing irreversible damage being done to the suppressor.The SRD-10 is intended for use with these applications:An SRS® 300 Self-Regenerating Suppressor that is operated in the external water modeAn MMS™ 300 MicroMembrane™ Suppressor that is operated in the chemical regenerant modeIn the external water mode of operation, an external water supply is pumped into the SRS regenerant channels. A constant current is applied across the electrodes in the SRS to electrolytically regenerate the device. It is possible for the IC (ion chromatography) system tocontinue to operate and for current to be applied to the SRS even after external water flow has stopped or the water supply is depleted. Unless the current is turned off, this will quickly cause irreversible damage to the SRS.In the chemical regenerant mode of operation, running out of regenerant will not damage the MMS, but it will adversely affect the chromatographic run.In either of these scenarios, the SRD-10 will shut off the eluent pump, stopping the run. In the case of the SRS, the eluent pump shut off will switch off the suppressor.ManualsSRD-10 Suppressor Regenerant Detector Installation Instructions
  • Dionex ERD 500 电解再生抑制器 085087
    Dionex ERD 500 电解再生抑制器收集寡糖分数以较少的努力,并与离子色谱法(IC)在自动pH值的降低和除盐由高pH值淋洗液。 Thermo Scientific的™ 戴安™ ERD™ 500电解再生脱盐去除从碱性醋酸钠流出物的钠离子(Na +的)一致,如与脉冲安培检测(HPAE-PAD)高pH阴离子交换色谱法之后。Dionex ERD 500 电解再生抑制器订货信息:ERD 500 Electrolytically Regenerated Desalter (4 mm)085087ERD 500 Electrolytically Regenerated Desalter (2 mm)085089On-line Device for Users of HPAE-PAD to Collect and Further Analyze Carbohydrate SamplesHigh-pH HPAE-PAD has become the method of choice for oligosaccharide purification because it permits very high resolution of neutral and charged oligosaccharide isomers. Subsequent characterization of purified oligosaccharides often requires removal of eluent salts. Manual desalting methods are available the Thermo Scientific™ Dionex™ ERD™ 500 Electrolytcally Regenerated Desalter provides an easier, automated method.Reduces the pH of the effluent from pH ~13 to between pH 2–6Supports lyophilization of collected fractions without dialysisProvides minimal dispersion of the sample exiting the detector cellLow dispersion for accurate fraction collection99% sodium ions removed from eluents that contain up to 0.35 M sodium ionsThe Dionex ERD 500 desalter exchanges sodium ions in the eluent for hydronium ions. This process converts sodium hydroxide and sodium acetate eluents to water and acetic acid, lowering sample pH after samples leave the detector cell. Because acetic acid is volatile, fractions can then be lyophilized without dialysis, leaving the purified carbohydrate sample ready for further manipulation.The Dionex ERD 500 desalter reliably desalts up to 0.35 M Na at an eluent flow of 1.0 mL/min. Oligosaccharides eluting in up to 0.35 M Na, collected after on-line desalting and evaporated in a centrifugal vacuum evaporator, exhibit residual [Na+] below 200 μM after resuspension to original volume in deionized water. This represents a desalting efficiency of 99.9%. ManualsERD 500 Electrolytically Regenerated Desalter
  • KBW系列植物生长箱
    KBW 系列 &mdash &mdash 植物生长箱 提供对自然光照条件完美的模拟,创造理想和恒定的生长环境。 性能特点: &bull 电子控制的 APT.line® 内腔预热技术 &bull 温度范围:-10℃至 -60℃ &bull MP 控制器,具有 2 个程序(每个 10 节)或可切换到 1 个程序(20 节),用于编程白天 / 夜间循环 &bull 单个程序各节的间隔时间可调整到最长 99:59 小时或 999:59 小时 &bull 定时器功能:延时开启、延时关闭和依赖于温度的延时关闭 &bull 风扇速度可调(0 至 100%) &bull 光照:灵活可调的光照盒,每盒有 4 只日光灯管(KBW 720 有 8 只灯管)有三级开关控制 (关 -50%-100%) &bull 接入口:Ø 30 毫米 &bull 独立的可调温度安全装置,3.1 级(DIN 12880),带有可视和声音报警器 &bull RS 422 接口,用于通讯软件 APT-COM® 数据控制系统,或采用 RS 232/RS 422 接口转换器转换到 打印机输出口;打印间隔可调 &bull 选项:根据光强和实际用途,可选择不同光源&mdash &mdash 日光灯、生长灯、Arabidopsis ( 拟南芥 ) 灯 型号KBW 240/KBWF 240 KBW 400 KBW 720/KBWF 720 热烈祝贺北京美同达科技有限公司成为美国VWR公司北方区授权总代理!即日起全线销售VWR International产品。更多新品优惠促销!详细请致致电010-52457812/52457811/88482632!
  • Dionex ERS 500 电解再生抑制器 | 082540,082542
    Dionex ERS 500 电解再生抑制器该下一代抑制器拥有高容量、低噪音、耐高反压和快速启动的特点,可满足当前各种离子色谱应用需求。最新的电解抑制器是一款真正的主力设备,几乎适用于所有分析型 IC 应用。拥有高容量、低噪音、耐高反压、快速启动,该新一代抑制器专为 IC 新需求而设计。Thermo Scientific™ Dionex™ ERS™ 500 电解再生抑制器使峰扩散最小化,提高峰效率,配合4μm 色谱柱效果更佳。该抑制器与高效 4μm 离子交换色谱柱匹配而起开发,在保持卓越分辨率的情况下以更高的流速实现更快的分离,或在保持样品通量的情况下以相同流速实现更高分辨率。该高容量抑制器几乎支持所有分析型 的 IC 应用,可用于阴离子和阳离子分析,提供 2mm 和 4mm 两种规格。Dionex ERS 500 抑制器在标准孔 (4 mm) 和微孔 (2 mm) 规格下适用于碳酸盐(仅等度)、氢氧化物、甲基磺酸或硫酸淋洗液的等度或梯度应用。 下一代抑制器——专为 IC 应用新需求而造 由于其具有较高的反压耐受性(在高达 900 psi 的情况下无泄漏,在高达 200 psi时进行操作),提高了联用检测技术的兼容性,特别是质谱仪 较高的温度耐受性(在运输和储存中高达 80°C,操作时为 40°C) 凭借其平面的填充床抑制槽,无电流操作后,无需试剂完全电解再生即可轻松恢复 低峰扩散保持 4μm 色谱柱的峰形效率在无需化学再生的情况下重新启动之后,其高抑制容量可立即产生稳定的峰面积值 低噪音特性使抑制器适用于痕量分析 为更可靠定量提高灵敏度 与 Thermo Scientific™ Dionex™ CRD 300 碳酸盐去除装置配合使用时,Dionex ERS 500 抑制器在碳酸盐淋洗液条件下,能够降低背景电导和噪音、增强分析物响应和检测灵敏度,从而提高定量的可靠性。 对实现Reagent-Free™ IC (RFIC™ ) 操作十分重要 无需试剂的完全再生 Dionex ERS 500 抑制器可直接替代 Thermo Scientific™ Dionex™ SRS™ 300 自再生抑制器。 The Dionex ERS 500 suppressor designThe Dionex ERS 500 suppressor components and assembly订货信息:The Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor is compatible with Thermo Scientific Dionex IC systems equipped with a suppressor power supply. The new Dionex ERS 500 suppressors directly replace the Dionex SRS 300 suppressors. Simply install the new Dionex ERS 500 suppressor into your current Dionex IC system. ERS 500 Electrolytically Regenerated SuppressorDionex AERS 500 (4 mm) Suppressor082540Dionex AERS 500 (2 mm) Suppressor082541 Dionex CSRS 500 (4 mm) Suppressor082542Dionex CERS 500 (2 mm) Suppressor082543Introducing the Thermo Scientific Dionex ERS 500 Suppressor Thermo Fisher Scientific is pleased to announce the introduction of the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. The Dionex ERS 500 suppressor is a direct replacement for the Thermo Scientific™ Dionex™ SRS™ 300 Self-Regenerating Suppressor.The Dionex ERS 500 suppressors have the same fit, form and function as the Dionex SRS 300 suppressors they have been designed to directly address all the applications currently addressed by the Dionex SRS 300 suppressors with the following exception: The Dionex ERS 500 suppressor does not support the chemical regeneration mode. The Thermo Scientific™ Dionex™ MicroMembrane™ MMS 300 Suppressor is recommended for chemical regeneration mode.The key benefits of the new Dionex ERS 500 suppressor are: Improved peak efficiency for improved performance, particularly when coupled with 4 μm based columns.Improved back pressure resiliency for compatibility with a wider range of hyphenated detection techniques.Improved thermal stability to eliminate installation failures due to damage during shipment, handling and operation.Full electrolytic regeneration without reagents allowing easier recoveries after operation without current.With the introduction of the Dionex ERS 500 suppressor, sales of the Dionex SRS 300 suppressor are being discontinued. Thermo Fisher Scientific will no longer receive orders for the Dionex SRS 300 suppressor once it is discontinued. High-Capacity Electrolytically Regenerated Suppressor for Use with IC EluentsThe Dionex ERS 500 Electrolytically Regenerated Suppressor serves virtually all analytical scale1 IC applications for both anions and cations. For anions, the preferred eluent is hydroxide. With Reagent-Free™ Ion Chromatography (RFIC)systems, the sample is determined using conductivity detection in the lowest possible background of high-purity water. AutoSuppression means ease of use you don’t need to make regenerant because the suppressor is constantly regenerated by the continuous electrolysis of water. The Dionex ERS 500 suppressor offers: Low background noise levelsExcellent peak efficiency for compatibility with 4 μm based columnsFast startup equilibration timesTrace anion and cation determinationsCompatibility with hyphenated detection techniques including mass spectrometry detectionCompatibility with all Thermo Scientific Dionex ICS chromatography modules2A three-fold increase in backpressuretolerance compared to previous generationsFull electrolytic regeneration without reagentsThe Dionex ERS 500 suppressor delivers low backgrounds and low noise levels for the full range of ion-exchange Dionex IonPac columns and eluents, even under high-concentration gradient conditions. When combined with the revolutionary Eluent Generator, the Dionex ERS 500 suppressor delivers truly automated, minimal-maintenance RFIC. 1For capillary scale IC applications use the Thermo Scientific Dionex CES 300 Capillary Electrolytic Suppressor.2Excluding the Dionex ICS-90, ICS-90A, ICS-600 and ICS-900 systems. Older systems may require the Thermo Scientific Dionex RFC-10 or RFC-30 controller.Dionex ERS 500 Electrolytically Regenerated Suppressor SpecificationsDionex AERS 500 SuppressorPhysical SpecificationsDimensions (l × w × d)12.1 × 4.5 × 4.8 cm (4.25 × 1.8 × 1.9 in.)Weight295 g (0.65 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsOperational Temperature Range115–40° CShipping Temperature Range20–70° C Recommended Backpressure30–60 psiMaximum Eluent Flow Rate3 mL/min (4 mm)1 mL/min (2 mm)Eluent Solvent Restrictions340% solvents in EWM4Maximum Regenerant EWM4 Flow Rate 5 mL/min (4 mm)2 mL/min (2 mm)Modes of Operation SupportedRecycle, EWM4, MPIC5(recycle recommended)6Maximum Current500 mA for 4 mm,100 mA for 2 mmDionex CERS 500 Suppressor Physical SpecificationsDimensions (l × w × d)12.1 × 4.5 × 4.8 cm (4.25 × 1.8 × 1.9 in.)Weight295 g (0.65 lb)Void volume4 mm: 50 μL2mm: 15 μLChemical SpecificationsTemperature Range115–40° CShipping Temperature Range20–70° CRecommended Backpressure
  • Dionex CERS 500 阳离子抑制器 | 082542,082543
    Dionex CERS 500 电解再生阳离子抑制器该下一代抑制器拥有高容量、低噪音、耐高反压和快速启动的特点,可满足当前各种离子色谱应用需求。最新的电解抑制器是一款真正的主力设备,几乎适用于所有分析型 IC 应用。拥有高容量、低噪音、耐高反压、快速启动,该新一代抑制器专为 IC 新需求而设计。Thermo Scientific™ Dionex™ ERS™ 500 电解再生抑制器使峰扩散最小化,提高峰效率,配合4μm 色谱柱效果更佳。该抑制器与高效 4μm 离子交换色谱柱匹配而起开发,在保持卓越分辨率的情况下以更高的流速实现更快的分离,或在保持样品通量的情况下以相同流速实现更高分辨率。该高容量抑制器几乎支持所有分析型 的 IC 应用,可用于阳离子分析,提供 2mm 和 4mm 两种规格。Dionex CERS 500 抑制器在标准孔 (4 mm) 和微孔 (2 mm) 规格下适用于碳酸盐(仅等度)、氢氧化物、甲基磺酸或硫酸淋洗液的等度或梯度应用。 下一代抑制器——专为 IC 应用新需求而造 由于其具有较高的反压耐受性(在高达 900 psi 的情况下无泄漏,在高达 200 psi 时进行操作),提高了联用检测技术的兼容性,特别是质谱仪 较高的温度耐受性(在运输和储存中高达 80°C,操作时为 40°C) 凭借其平面的填充床抑制槽,无电流操作后,无需试剂完全电解再生即可轻松恢复 低峰扩散保持 4μm 色谱柱的峰形效率在无需化学再生的情况下重新启动之后,其高抑制容量可立即产生稳定的峰面积值 低噪音特性使抑制器适用于痕量分析 为更可靠定量提高灵敏度 与 Thermo Scientific™ Dionex™ CRD 300 碳酸盐去除装置配合使用时,Dionex AERS 500 抑制器在碳酸盐淋洗液条件下,能够降低背景电导和噪音、增强分析物响应和检测灵敏度,从而提高定量的可靠性。 对实现Reagent-Free™ IC (RFIC™ ) 操作十分重要 无需试剂的完全再生 Dionex AERS 500 抑制器可直接替代 Thermo Scientific™ Dionex™ SRS™ 300 自再生抑制器。 订货信息:The Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor is compatible with Thermo Scientific Dionex IC systems equipped with a suppressor power supply. The new Dionex ERS 500 suppressors directly replace the Dionex SRS 300 suppressors. Simply install the new Dionex ERS 500 suppressor into your current Dionex IC system.CERS 500 Electrolytically Regenerated SuppressorDionex CERS 500 (4 mm) Suppressor082542Dionex CERS 500 (2 mm) Suppressor082543Introducing the Thermo Scientific Dionex ERS 500 Suppressor Thermo Fisher Scientific is pleased to announce the introduction of the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. The Dionex ERS 500 suppressor is a direct replacement for the Thermo Scientific™ Dionex™ SRS™ 300 Self-Regenerating Suppressor.The Dionex ERS 500 suppressors have the same fit, form and function as the Dionex SRS 300 suppressors they have been designed to directly address all the applications currently addressed by the Dionex SRS 300 suppressors with the following exception:The Dionex ERS 500 suppressor does not support the chemical regeneration mode. The Thermo Scientific™ Dionex™ MicroMembrane™ MMS 300 Suppressor is recommended for chemical regeneration mode.The key benefits of the new Dionex ERS 500 suppressor are:Improved peak efficiency for improved performance, particularly when coupled with 4 μm based columns.Improved back pressure resiliency for compatibility with a wider range of hyphenated detection techniques. Improved thermal stability to eliminate installation failures due to damage during shipment, handling and operation.Full electrolytic regeneration without reagents allowing easier recoveries after operation without current.With the introduction of the Dionex ERS 500 suppressor, sales of the Dionex SRS 300 suppressor are being discontinued. Thermo Fisher Scientific will no longer receive orders for the Dionex SRS 300 suppressor once it is discontinued. High-Capacity Electrolytically Regenerated Suppressor for Use with IC EluentsThe Dionex ERS 500 Electrolytically Regenerated Suppressor serves virtually all analytical scale1 IC applications for both anions and cations. For anions, the preferred eluent is hydroxide. With Reagent-Free™ Ion Chromatography (RFIC)systems, the sample is determined using conductivity detection in the lowest possible background of high-purity water. AutoSuppression means ease of use you don’t need to make regenerant because the suppressor is constantly regenerated by the continuous electrolysis of water. The Dionex ERS 500 suppressor offers: Low background noise levelsExcellent peak efficiency for compatibility with 4 μm based columnsFast startup equilibration timesTrace anion and cation determinationsCompatibility with hyphenated detection techniques including mass spectrometry detectionCompatibility with all Thermo Scientific Dionex ICS chromatography modules2A three-fold increase in backpressure tolerance compared to previous generationsFull electrolytic regeneration without reagents The Dionex ERS 500 suppressor delivers low backgrounds and low noise levels for the full range of ion-exchange Dionex IonPac columns and eluents, even under high-concentration gradient conditions. When combined with the revolutionary Eluent Generator, the Dionex ERS 500 suppressor delivers truly automated, minimal-maintenance RFIC. 1For capillary scale IC applications use the Thermo Scientific Dionex CES 300 Capillary Electrolytic Suppressor.2Excluding the Dionex ICS-90, ICS-90A, ICS-600 and ICS-900 systems. Older systems may require the Thermo Scientific Dionex RFC-10 or RFC-30 controller.Dionex ERS 500 Electrolytically Regenerated Suppressor SpecificationsDionex AERS 500 SuppressorPhysical SpecificationsDimensions (l × w × d)12.1 × 4.5 × 4.8 cm (4.25 × 1.8 × 1.9 in.)Weight295 g (0.65 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsOperational Temperature Range115–40° CShipping Temperature Range20–70° CRecommended Backpressure30–60 psiMaximum Eluent Flow Rate3 mL/min (4 mm)1 mL/min (2 mm)Eluent Solvent Restrictions340% solvents in EWM4Maximum Regenerant EWM4 Flow Rate5 mL/min (4 mm)2 mL/min (2 mm)Modes of Operation SupportedRecycle, EWM4, MPIC5(recycle recommended)6Maximum Current500 mA for 4 mm,100 mA for 2 mmDionex CERS 500 SuppressorPhysical SpecificationsDimensions (l × w × d)12.1 × 4.5 × 4.8 cm (4.25 × 1.8 × 1.9 in.)Weight295 g (0.65 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsTemperature Range115–40° CShipping Temperature Range20–70° CRecommended Backpressure30–60 psiMaximum Eluent Flow Rate
  • Dionex AERS 500 阴离子抑制器 | 082540,082541
    Dionex AERS 500 电解再生抑制器该下一代抑制器拥有高容量、低噪音、耐高反压和快速启动的特点,可满足当前各种离子色谱应用需求。最新的电解抑制器是一款真正的主力设备,几乎适用于所有分析型 IC 应用。拥有高容量、低噪音、耐高反压、快速启动,该新一代抑制器专为 IC 新需求而设计。Thermo Scientific™ Dionex™ ERS™ 500 电解再生抑制器使峰扩散最小化,提高峰效率,配合4μm 色谱柱效果更佳。该抑制器与高效 4μm 离子交换色谱柱匹配而起开发,在保持卓越分辨率的情况下以更高的流速实现更快的分离,或在保持样品通量的情况下以相同流速实现更高分辨率。该高容量抑制器几乎支持所有分析型 的 IC 应用,可用于阴离子分析,提供 2mm 和 4mm 两种规格。Dionex AERS 500 抑制器在标准孔 (4 mm) 和微孔 (2 mm) 规格下适用于碳酸盐(仅等度)、氢氧化物、甲基磺酸或硫酸淋洗液的等度或梯度应用。 下一代抑制器——专为 IC 应用新需求而造 由于其具有较高的反压耐受性(在高达 900 psi 的情况下无泄漏,在高达 200 psi 时进行操作),提高了联用检测技术的兼容性,特别是质谱仪 较高的温度耐受性(在运输和储存中高达 80°C,操作时为 40°C) 凭借其平面的填充床抑制槽,无电流操作后,无需试剂完全电解再生即可轻松恢复 低峰扩散保持 4μm 色谱柱的峰形效率在无需化学再生的情况下重新启动之后,其高抑制容量可立即产生稳定的峰面积值 低噪音特性使抑制器适用于痕量分析 为更可靠定量提高灵敏度 与 Thermo Scientific™ Dionex™ CRD 300 碳酸盐去除装置配合使用时,Dionex AERS 500 抑制器在碳酸盐淋洗液条件下,能够降低背景电导和噪音、增强分析物响应和检测灵敏度,从而提高定量的可靠性。 对实现Reagent-Free™ IC (RFIC™ ) 操作十分重要 无需试剂的完全再生 Dionex AERS 500 抑制器可直接替代 Thermo Scientific™ Dionex™ SRS™ 300 自再生抑制器。 订货信息:The Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor is compatible with Thermo Scientific Dionex IC systems equipped with a suppressor power supply. The new Dionex ERS 500 suppressors directly replace the Dionex SRS 300 suppressors. Simply install the new Dionex ERS 500 suppressor into your current Dionex IC system.AERS 500 Electrolytically Regenerated SuppressorDionex AERS 500 (4 mm) Suppressor082540Dionex AERS 500 (2 mm) Suppressor082541Introducing the Thermo Scientific Dionex ERS 500 Suppressor Thermo Fisher Scientific is pleased to announce the introduction of the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. The Dionex ERS 500 suppressor is a direct replacement for the Thermo Scientific™ Dionex™ SRS™ 300 Self-Regenerating Suppressor.The Dionex ERS 500 suppressors have the same fit, form and function as the Dionex SRS 300 suppressors they have been designed to directly address all the applications currently addressed by the Dionex SRS 300 suppressors with the following exception:The Dionex ERS 500 suppressor does not support the chemical regeneration mode. The Thermo Scientific™ Dionex™ MicroMembrane™ MMS 300 Suppressor is recommended for chemical regeneration mode.The key benefits of the new Dionex ERS 500 suppressor are:Improved peak efficiency for improved performance, particularly when coupled with 4 μm based columns.Improved back pressure resiliency for compatibility with a wider range of hyphenated detection techniques.Improved thermal stability to eliminate installation failures due to damage during shipment, handling and operation.Full electrolytic regeneration without reagents allowing easier recoveries after operation without current.With the introduction of the Dionex ERS 500 suppressor, sales of the Dionex SRS 300 suppressor are being discontinued. Thermo Fisher Scientific will no longer receive orders for the Dionex SRS 300 suppressor once it is discontinued. High-Capacity Electrolytically Regenerated Suppressor for Use with IC EluentsThe Dionex ERS 500 Electrolytically Regenerated Suppressor serves virtually all analytical scale1 IC applications for both anions and cations. For anions, the preferred eluent is hydroxide. With Reagent-Free™ Ion Chromatography (RFIC)systems, the sample is determined using conductivity detection in the lowest possible background of high-purity water. AutoSuppression means ease of use you don’t need to make regenerant because the suppressor is constantly regenerated by the continuous electrolysis of water. The Dionex ERS 500 suppressor offers: Low background noise levelsExcellent peak efficiency for compatibility with 4 μm based columnsFast startup equilibration timesTrace anion and cation determinationsCompatibility with hyphenated detection techniques including mass spectrometry detectionCompatibility with all Thermo Scientific Dionex ICS chromatography modules2A three-fold increase in backpressure tolerance compared to previous generationsFull electrolytic regeneration without reagents The Dionex ERS 500 suppressor delivers low backgrounds and low noise levels for the full range of ion-exchange Dionex IonPac columns and eluents, even under high-concentration gradient conditions. When combined with the revolutionary Eluent Generator, the Dionex ERS 500 suppressor delivers truly automated, minimal-maintenance RFIC. 1For capillary scale IC applications use the Thermo Scientific Dionex CES 300 Capillary Electrolytic Suppressor.2Excluding the Dionex ICS-90, ICS-90A, ICS-600 and ICS-900 systems. Older systems may require the Thermo Scientific Dionex RFC-10 or RFC-30 controller.Dionex ERS 500 Electrolytically Regenerated Suppressor SpecificationsDionex AERS 500 SuppressorPhysical SpecificationsDimensions (l × w × d)12.1 × 4.5 × 4.8 cm (4.25 × 1.8 × 1.9 in.)Weight295 g (0.65 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsOperational Temperature Range115–40° CShipping Temperature Range20–70° CRecommended Backpressure30–60 psiMaximum Eluent Flow Rate3 mL/min (4 mm)1 mL/min (2 mm)Eluent Solvent Restrictions340% solvents in EWM4Maximum Regenerant EWM4 Flow Rate5 mL/min (4 mm)2 mL/min (2 mm)Modes of Operation SupportedRecycle, EWM4, MPIC5(recycle recommended)6Maximum Current500 mA for 4 mm,100 mA for 2 mmDionex CERS 500 SuppressorPhysical SpecificationsDimensions (l × w × d)12.1 × 4.5 × 4.8 cm (4.25 × 1.8 × 1.9 in.)Weight295 g (0.65 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsTemperature Range115–40° CShipping Temperature Range20–70° CRecommended Backpressure30–60 psiMaximum Eluent Flow Rate
  • 088666(旧货号082540)阴离子抑制器ADRS 600(4MM)赛默飞
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific™ Dionex™ DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC™ ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For usewith 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm) CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM) 088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091 PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • 088670抑制器CDRS 600(2MM)赛默飞082543旧货号
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific™ Dionex™ DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC™ ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For usewith 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm) CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM) 088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091 PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • 全光谱组培灯 育苗灯 T8植物生长灯 组培灯
    全光谱组培灯 LED植物生长补光灯 育苗灯 T8植物生长灯 组培灯节能省电50%,可免空调降温; 提高植物生长周期,一个月可提前5天; 提高品质,100颗育苗可达98%成活;育苗均匀成长,不出现高低不平; 根粗枝大,叶子绿,易出口; LED植物灯减少植物畸形; LED植物灯光衰小可达千分之一内;8、寿命长3-4年无需更换;产品由上海书培实验设备有限公司专业提供,产品长度可选,量多从优,欢迎客户来电咨询选购。全光谱组培灯 LED植物生长补光灯产品介绍:颜色:红白发光颜色:白色电压:220v功率:18W灯头接头型号:T8形状:条形长度可选:0.6米,0.9米,1.2米
  • 088667抑制器,, ADRS 600(2MM)赛默飞082541替代产品
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific™ Dionex™ DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC™ ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For usewith 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm) CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM) 088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091 PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • 088668阳离子抑制器CDRS 600(4MM)赛默飞旧货号082542
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific™ Dionex™ DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC™ ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For usewith 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm) CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM) 088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091 PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • Dionex™ DRS600动态再生抑制器 离子色谱应用 088666
    Dionex DRS 600 Suppressors抑制器Use the Thermo Scientific™ Dionex™ DRS 600 Dynamically Regenerated Suppressor for electrolytically regenerated suppression in ion chromatography (IC) applications requiring high capacity, low noise, high backpressure resiliency, and fast startup. The Dionex DRS 600 Suppressor operates in constant voltage mode as well as the traditional constant current mode. By operating in constant voltage mode, the Dionex DRS 600 Suppressor self-governs electrical current as long as a constant voltage is applied. This suppressor is a fundamental component of a reagent-free ion chromatography (RFIC™ ) system.描述Dionex DRS 600 makes analysis easier for system operatorsMinimizes training and operation time by eliminating error-prone manual calculation of electrical currentsImproves gradient performance by improving signal-to-noise ratio with gradient eluents by dynamically adapting to the changing eluent compositionCompatible across a wide variety of applicationsThe Dionex ADRS 600 Anion Dynamically Regenerated Suppressor allows external water mode operation and enables analyses requiring IC coupled with mass spectrometry (MS).The Dionex DRS 600 Dynamically Regenerated Suppressor is a direct replacement for the Thermo Scientific™ Dionex™ ERS™ 500 Electrolytically Regenerated Suppressor. 1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For use with 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079)suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm)CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM)088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • ASRS300阴离子抑制器 赛默飞离子老款抑制器 SP6949
    Dionex DRS 600 Suppressors抑制器1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For use with 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079) suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm)CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM)088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • 赛默飞 戴安 SP6949 阴离子抑制
    Dionex DRS 600 Suppressors抑制器1、Dionex ADRS 600 (2 mm) Anion Electrolytically Regenerated Suppressor 088667For use with 2 and 3 mm microbore anion-exchange columns. Replaces the Dionex AERS 500 (P/N 082541),Dionex ASRS 300 (P/N SP6948), ASRS ULTRA II (P/N 061562), ASRS ULTRA (P/N 053947), ASRS I (P/N 043187),and the ASRS II (P/N 046078) suppressors.2、Dionex ADRS 600 (4 mm) Anion Electrolytically Regenerated Suppressor 088666For use with 4 and 5 mm anion-exchange columns. Replaces the Dionex AERS 500 (4mm) P/N 082540,Dionex ASRS 300 (P/N SP6949), ASRS ULTRA II (P/N 061561), ASRS (P/N 053946), ASRS I (P/N 043189), and theASRS II (P/N 046081) suppressors.3、Dionex CDRS 600 (2 mm) Cation Electrolytically Regenerated Suppressor 088670For use with 2 and 3 mm microbore cation-exchange columns. Replaces the Dionex CERS 500 (2mm) P/N 082543,Dionex CSRS 300 (P/N SP6950), CSRS ULTRA II (P/N 061564), CSRS ULTRA (P/N 053949), CSRS I (P/N 043188),and the CSRS II (P/N 046080) suppressors.4、Dionex CDRS 600 (4 mm) P/N 082542 Cation Electrolytically Regenerated Suppressor 088668For use with 4 mm cation-exchange columns. Replaces the Dionex CSRS 300 (P/N SP6951), CSRS ULTRA II(P/N 061563), CSRS ULTRA (P/N 053948), CSRS I (P/N 043190), and the CSRS II (P/N 046079) suppressors. SP6948ASRS 300(2 mm)ASRS300 阴离子抑制器-老款2MMSP6949ASRS 300(4 mm)ASRS300 阴离子抑制器-老款4MMSP6950CSRS 300(2 mm)CSRS300 阳离子抑制器-老款2MMSP6951CSRS 300(4 mm)CSRS300 阳离子抑制器-老款4MM088666Suppressor, ADRS 600(4MM)抑制器, ADRS 600(4MM)088667Suppressor, ADRS 600(2MM)抑制器,, ADRS 600(2MM)088668Suppressor, CDRS 600(4MM)抑制器,, CDRS 600(4MM)088670Suppressor, CDRS 600(2MM)抑制器,, CDRS 600(2MM)085090PROD,ACRS,4MMACRS 阴离子化学抑制器4MM085091PROD,ACRS,2MMACRS 阴离子化学抑制器2MM085092PROD,CCRS,4MMCCRS 阳离子化学抑制器4MM085093PROD,CCRS,2MMCCRS 阳离子化学抑制器2MM
  • Dione CES 300毛细管电解抑制器 072052
    Dione CES 300毛细管电解抑制器毛细管电解抑制器(CES 300),毛细管IC分析在CES 300毛细管电解抑制器是为常见于毛细管系统洗脱液流量优化(5 - 30μL/分钟)。当用于阴离子分析,ACES 300高度导电基于氢氧化淋洗液转换成纯净水,减少了基线电导率。同时抑制洗脱液中,ACES 300也被分析物转换成他们更多的导电离子(酸)的形式,增加电导检测下的灵敏度。同样,用于阳离子分析时,™ 300的CCES转换高度导电甲磺酸(MSA)淋洗液成纯净水 同时,分析物转化成其多个导电氢氧化物形式,增加了它们的灵敏度。Dione CES 300毛细管电解抑制器订货信息:ACES 300 Anion Capillary Electrolytic Suppressor072052CCES 300 Cation Capillary Electrolytic Suppressor072053Capillary Electrolytic Suppressor (CES™ 300) for Capillary IC AnalysisThe CES 300 Capillary Electrolytic Suppressors are optimized for eluent flow rates typically seen in capillary systems(5 – 30 μL/min). When used for anion analysis, the ACES™ 300 converts highly conductive hydroxide-based eluents into pure water, reducing the baseline conductivity. While suppressing the eluent, the ACES 300 also converts the analytes into their more conductive hydronium (acid) form, increasing their sensitivity under conductivity detection. Likewise, when used for cation analysis, the CCES™ 300 converts highly conductive methanesulfonic acid (MSA) eluents into pure water simultaneously, the analytes are converted to their more conductive hydroxide form, increasing their sensitivity.CES 300 TechnologyThe CES suppressor uses a three-chamber design to minimize dead volume while maximizing suppression capacity and reducing noise.The eluent chamber is comprised of an ion-exchange capillary membrane that facilitates the efficient exchange of the eluent counter ions for regenerant ions.The regenerant chambers are divided into ion-exchange and electrode chambers. Regenerant first passes through the ion- exchange chamber, which is filled with a bed of ion exchange resin the ion exchange capillary membrane is coiled in this bed. The regenerant bed is an ion exchange resin in the opposite form as the eluent. It is this bed of resin that provides the regenerant ions for the capillary membrane eluent chamber.There are two electrode chambers that are separated from the ion-exchange chamber by a pair of ion exchange membranes. Regenerant, after passing through the ion-exchange chamber, passes through the cathode and anode chambers serially. When current is passed through the electrodes, regenerant ions are generated in the first electrode chamber these ions are pushed into the ion-exchange chamber via an electric field, maintaining the ion exchange chamber in the regenerant form. After counterions exchange from the eluent ion exchange capillary membrane, they are are removed from the ion exchange chamber via the electric field into the second Electrode chamber. Finally, the counterions are neutralized by the ions generated in the second electrode chamber.Anion Capillary Electrolytic Suppressor (ACES 300).CES 300 System ControlThe unique design of the CES 300 simplifies software and hardware control options. For most applications, the CES 300 can be set to a single current setting of 10 mA. For applications requiring very high eluent concentrations, the CES 300 should be set to 20 mA. The ICS-5000 includes software and hardware to control the CES 300 suppressor. Chromeleon 6.8 or 7.x is required.Key Applications Using a CES SuppressorSeparation of 22 anions on an IonPac AS19 Capillary column.Separation of six common cations using an IonPac® CS12A Capillary column.Capillary Electrolytic Suppressor (CES 300) SpecificationsPhysical SpecificationsDimensions (l × w × d):9.4 × 3.1 × 10.3 cm (3.7 × 1.2 × 4.1 in.)Weight:150 g (0.33 lb)Void volume:1.5 μLChemical SpecificationsTemperature Range:15° C1Recommended Backpressure:20–100 psiMaximum Eluent Flow Rate:0.030 mL/minEluent Solvent Restrictions2:40% solvents in EWM3Maximum Regenerant EWM3 Flow Rate:0.100 mL/minModes of Operation Supported:Recycle, EWM3(recycle recommended)4Maximum Current:20 mA(10 mA recommended for most applications)1Requires 15°C for recycled eluent mode of operation.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = External Water Mode.4Recycle recommended for aqueous applications without solvent.Data SheetsRFIC Eluent Suppressors for Ion Chromatography Data SheetThermo Scientific Dionex Eluent Suppressors for Ion ChromatographyManualsCES 300 Capillary Electrolytic Suppressor Product Manual
  • SC-CSRS 300 盐转换器阳离子自再生抑制器
    Dionex SC-CSRS 300 盐转换器阳离子自再生抑制器通过使用 Thermo Scientific™ Dionex™ SC-CSRS™ 300 盐转换器阳离子自再生抑制器来将弱电离有机胺和铵根转化为用于电导检测的高度离子化甲磺酸 (MSA),从而提高被分析物响应,并且将线性范围扩大三倍之多。提供 4 mm 规格(与 4 mm 和 5 mm 柱配合使用)和 2 mm 规格(与 2 mm 和 3 mm 柱配合使用),这款易于使用的自再生抑制器不需要再生液。描述针对胺、铵、以及第I、II族阳离子的强化性能将线性范围最多扩大三个数量级提高对广泛铵或胺浓度的样品的灵敏度用于更高浓度样品时的准确度更高,减少了所需的校准检查标准品数量提高具有高样品工作负荷行业(例如发电工业)的样品通量更新的设计,更高的耐反压能力以及最高的抗泄漏性能得益于创新的再生液清除设计,实现更低噪音和快速启动自再生功能,节省时间Dionex SC-CSRS 300 盐转换器阳离子自再生抑制器订货信息:SC-CSRS 300 (4 mm) Salt Converter-Cation Self-Regenerating Suppressor067530SC-CSRS 300 (2 mm) Salt Converter-Cation Self-Regenerating Suppressor067529Converts Analytes to the Fully-Dissociated Methanesulfonic Acid SpeciesWith the SC-CSRS 300, nonlinear response of ammonia and certain amines can be overcome by converting the weak base analyte to a fully ionized form, thus extending the linear response. The SC-CSRS 300 suppressor is designed to make this conversion and provide linearity across as much as three orders of magnitude.Increased linearity for ammonium and aminesIncreased sensitivity for ammonium and aminesLow background and noiseConversion to and detection as fully dissociated methanesulfonic acidThe SC-CSRS should be used in industries where regulated methods require a linear response. A linear response increases accuracy at higher concentrations, and so requires fewer calibration check standards over the calibration curve. Reduced calibration requirements increase sample throughput for industries with high sample workloads such as the power generation industry.Method detection limits for Group I and II cations, ammonium, and amines using the SC-CSRS are equivalent to or better than those achieved using the CSRS 300. Salt Converter Cation Self-Regenerating Suppressor (SC-CSRS) SpecificationsEluent Suppressor Component (ES)Dimensions16 × 3.5 × 3.5 cm (6.6 × 1.8 × 1.7 in.)Void volume4 mm: 50 μL2 mm: 15 μLWeight0.4 kg (1 lb)Analyte Converter* Component (AC)Dimensions16 × 3.5 × 3.5 cm (6.6 × 1.8 × 1.7 in.)Void volume4 mm: 15 μL2 mm: 15 μLWeight0.4 kg (1 lb)*Low dispersion design used for both 4- and 2-mm SC-CSRS.Product Data SheetsSalt Converter-Cation Self-Regenerating Suppressor 300
  • Dionex CAES Atlas 阳离子电解抑制器 | 056118
    Dionex CAES Atlas 阳离子电解抑制器使用Thermo Scientific Dionex AES Atlas电解抑制器能够在离子分离时-尤其是在使用碳酸盐淋洗液情况下能够提高灵敏度和降低噪声.。你无需混入再生试剂, 该抑制器通过电解就能自动连续的再生。通过有效的交换反离子为再生离子,CAES Atlas 电解抑制器能够降低淋洗背景和增强待测离子响应。这种技术使用了由离子交换整体材料和流动分布盘构成的抑制床,配合Thermo Scientific Dionex MonoDisc and AutoSuppression 产品使用对碳酸盐淋洗系统发挥高效的噪声抑制:抑制洗脱达25μeq/min低背景电导优良的基线稳定性快速启动和平衡使用简单,无需维护 Low Noise Electrolytically Regenerated Suppressor for Use with IC EluentsThe Thermo Scientific Dionex Atlas™ Electrolytic Suppressor (AES™ ) is a continuous electrolytically-regenerated suppressor based on the MonoDisc™ and AutoSuppression™ products. The unique design of the Dionex AES suppressor enables very fast startup times and an extremely low noise level, particularly for carbonate eluents. The benefits of the Dionex AES suppressor include:High performance and very low noise for carbonate eluentsLow background conductivity, and excellent baseline stabilityEasy to use maintenance-free operationFast startup and equilibrationWill suppress eluents up to 25 μeq/minThe MonoDisc suppression bed of the Dionex AES is composed of ion-exchange monolith and flow distribution disks. This configuration facilitates efficient exchange of the eluent counter ions for regenerant ions, resulting in eluent suppression and analyte response enhancement.Atlas Electrolytic Suppressors SpecificationsCAESPhysical SpecificationsDimensions (l × w × d)4.9 × 4.4 × 10.2 cm (1.9 × 1.8 × 4.0 in.)Weight120 g (0.3 lb)Void volume35 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure20–100 psiMaximum Eluent Flow Rate3 mL/minEluent Solvent Restrictions20% solvents (no solvents)Maximum Regenerant EWM3 Flow Rate5 mL/minModes of Operation SupportedRecycle and external waterMaximum Current150 mA 1When installed outside the heated column enclosure, all suppressors can support applications up to 60 ?C.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = external water mode for eluents containing 40% solvent, use the chemical regeneration mode.订货信息:The Atlas suppressor is fully compatible with the ICS-5000, ICS-3000, ICS-2100, ICS-2000, ICS-1600, ICS-1500, ICS-1100, and ICS-1000 chromatography systems. It is not compatible with the ICS-90 or ICS-900. When ordering an Atlas suppressor for older systems, the DX-600, BioLC, or DX-320 systems must be configured with an ED50A, CD25A, or IC25A detector. The RFC-30 or RFC-10 Suppressor Controller must be ordered to use the Atlas with the earlier versions of detectors.Ordering InformationCation Atlas Electrolytic Suppressor056118Anion Atlas Electrolytic Suppressor056116
  • 聚焦离子束SW离子枪专用抑制极
    SUPPRESSOR,SW CONSUMABLE抑制极极电极,用于原厂聚焦离子束设备SW型号的离子枪,抑制极是聚焦离子束加载抑制极电压的电极,与拉出极配合,可对聚焦离子束的发射电流进行调节。大束科技是一家以自主技术驱动的电子显微镜系列核心配件研发制造的供应商和技术服务商。目前公司主要生产电子显微镜的核心配件离子源、电子源以及配套耗材抑制极、拔出极、光阑等销往国内外市场,此外,还为用户提供定制化电子显微镜以及电子枪系统等的维修服务,以及其他技术服务和产品升级等一站式、全方位的支持。在场发射电子源(电子显微镜灯丝)、离子源以及电镜上的高低压电源、电镜控制系统研发制造等领域等均具有优势。
  • 抑制器
    该高容量抑制器几乎支持所有分析型的 IC 应用,可用于阴离子和阳离子分析,提供 2 mm 和 4 mm 两种规格。Dionex ERS 500 和 Dionex ERS 500e 抑制器在标准孔 (4 mm) 和微孔 (2 mm) 规格下适用于碳酸盐(仅等度)、氢氧化物、甲磺酸或硫酸洗脱液的等度或梯度应用。下一代抑制器——专为 IC 应用新需求而制造由于其具有较高的反压耐受性(在高达 900 psi 的情况下无泄漏,在高达 200 psi 时进行操作),提高了联用检测技术(特别是质谱分析)的兼容性较高的温度耐受性(在运输和储存中高达 80°C,操作时为 40°C)凭借其平面的填充床抑制槽,无电流操作后,无需试剂完全电解再生即可轻松恢复低峰扩散保持 4 μm 色谱柱的峰形效率在无需化学再生的情况下重新启动之后,其高抑制容量可立即产生稳定的峰面积值低噪音特性使抑制器适用于痕量分析Dionex ERS 500e 抑制器 - 专为外加水模式应用而制造 再生室反压降低,便于实施加压储液箱输送。平行的再生剂流可使硼酸盐洗脱液和含有溶剂(高达 40%)的洗脱液的再生剂清除率大化。可用于化学再生剂模式。为更可靠定量提高灵敏度。与 Thermo Scientific™ Dionex™ CRD 300 碳酸盐去除装置配合使用时,Dionex ERS 500 和 Dionex ERS 500e 抑制器配合碳酸盐洗脱液,能够降低背景电导和噪音、增强分析物响应和检测灵敏度,从而提高定量的可靠性。对实现 Reagent-Free™ IC (RFIC™ ) 操作十分重要无需试剂的完全再生Dionex ERS 500 和 Dionex ERS 500e 抑制器可直接替代 Thermo Scientific™ Dionex™ SRS™ 300 自再生抑制器。
  • Dionex CCRS 500 阳离子抑制器 | 085090,085091
    Dionex CCRS 500 化学再生阳离子抑制器此款 Dionex CCRS 500 抑制器是一种化学再生抑制器,噪音极低,能快速启动。其高容量、溶剂相容性设计可处理多种复杂基质。Thermo Scientific Dionex CCRS 500 化学再生抑制器噪音低,能降低离子色谱分析 (IC) 检出限。Dionex CCRS 500 抑制器具备 2、4 mm 两种规格,其高容量、溶剂相容性设计可处理高度复杂基质。离子交换色谱的高容量、溶剂相容性抑制极低噪声的化学再生抑制器方法检出限低基线稳定性极佳快速启动和平衡易于使用,使用 DCR 试剂盒操作时无需维护峰效率和性能提高,特别是与 4 μm 柱配合使用时改进热稳定性,从而消除因运输、处理和操作过程中的损坏而造成的安装失败 注:为了使噪音最低和使用寿命最长,建议对使用含高效液相色谱 (HPLC) 溶剂的洗脱液的阴离子和阳离子分离使用本款抑制器。High-Capacity, Solvent-Compatible, Chemically-Regenerated Suppressor The Thermo Scienfitic Dionex CCRS 500 suppressor is a chemically-regenerated suppressor and therefore has very low noise and quick startup time. With the new Displacement Chemical Regeneration (DCR) Kit, this classic suppressor provides easier operation. The Dionex CCRS 500 suppressor advantages include:High-capacity and solvent-compatible design capable of handling samples with complex matricesVery low signal-to-noise and excellent baseline stabilityLow method detection limitsFast start-up and equilibrationEasy to use, maintenance-free operation with the DCR kitImproved peak efficiency for improved performance, particularly when coupled with 4 μm based columnsImproved thermal stability to eliminate installation failures due to damage during shipment, handling, and operationThe Dionex CCRS 500 suppressor has high capacity and can be used with all Thermo Scienfitic Dionex ion-exchange columns. For lowest noise and longest life, the Dionex CCRS 500 suppressor is recommended for anion and cation separations using eluents containing HPLC solvents. The Dionex CCRS 500 suppressor is available in both 2- and 4 mm formats 3 mm columns should be used with 2 mm suppressors.The Dionex CCRS 500 suppressor produces the lowest noise because it uses non-electrolytic chemical regeneration. Low noise levels translate into lower method detection limits.Chemically Regenerated Suppressor (CRS 500) SpecificationsCCRS 500Physical SpecificationsDimensions (l × w × d)14.0 × 4.5 × 4.8 cm (5.5 × 1.8 × 1.9 in.)Weight370 g (0.82 lb)Void volume4 mm: 50 μL2 mm: 15 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure30-100 psiMaximum Eluent Flow Rate3 mL/min (4 mm)0.75 mL/min (2 mm)Eluent Solvent Restrictions2100% solvent compatibleMaximum Regenerant EWM3 Flow Rate10 mL/min (4 mm)5 mL/min (2 mm)Modes of Operation SupportedChemical, DCR ModeMaximum Currentn/a1When installed outside the heated column enclosure, all suppressors can support applications up to 60 ?C.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = external water mode for eluents containing 40% solvent, use the chemical regeneration mode.订货信息:Ordering InformationCCRS 500 Suppressor 4 mm085092CCRS 500 Suppressor 2 mm085093
  • Dionex AAES Atlas 阴离子电解抑制器 | 056116
    Dionex AAES Atlas 阳离子电解抑制器使用Thermo Scientific Dionex AES Atlas电解抑制器能够在离子分离时-尤其是在使用碳酸盐淋洗液情况下能够提高灵敏度和降低噪声.。你无需混入再生试剂, 该抑制器通过电解就能自动连续的再生。通过有效的交换反离子为再生离子,AAES Atlas 电解抑制器能够降低淋洗背景和增强待测离子响应。这种技术使用了由离子交换整体材料和流动分布盘构成的抑制床,配合Thermo Scientific Dionex MonoDisc and AutoSuppression 产品使用对碳酸盐淋洗系统发挥高效的噪声抑制:抑制洗脱达25μeq/min低背景电导优良的基线稳定性快速启动和平衡使用简单,无需维护 Low Noise Electrolytically Regenerated Suppressor for Use with IC EluentsThe Thermo Scientific Dionex Atlas™ Electrolytic Suppressor (AES™ ) is a continuous electrolytically-regenerated suppressor based on the MonoDisc™ and AutoSuppression™ products. The unique design of the Dionex AES suppressor enables very fast startup times and an extremely low noise level, particularly for carbonate eluents. The benefits of the Dionex AES suppressor include:High performance and very low noise for carbonate eluentsLow background conductivity, and excellent baseline stabilityEasy to use maintenance-free operationFast startup and equilibrationWill suppress eluents up to 25 μeq/minThe MonoDisc suppression bed of the Dionex AES is composed of ion-exchange monolith and flow distribution disks. This configuration facilitates efficient exchange of the eluent counter ions for regenerant ions, resulting in eluent suppression and analyte response enhancement.Atlas Electrolytic Suppressors SpecificationsAAESPhysical SpecificationsDimensions (l × w × d)4.9 × 4.4 × 10.2 cm (1.9 × 1.8 × 4.0 in.)Weight120 g (0.3 lb)Void volume35 μLChemical SpecificationsTemperature Range115–40° CRecommended Backpressure20–100 psiMaximum Eluent Flow Rate3 mL/minEluent Solvent Restrictions20% solvents (no solvents)Maximum Regenerant EWM3 Flow Rate5 mL/minModes of Operation SupportedRecycle and external waterMaximum Current150 mA 1When installed outside the heated column enclosure, all suppressors can support applications up to 60 ?C.2Solvents for anion eluents include methanol. Solvents for cation eluents include acetonitrile and dioxane.3EWM = external water mode for eluents containing 40% solvent, use the chemical regeneration mode.订货信息:The Atlas suppressor is fully compatible with the ICS-5000, ICS-3000, ICS-2100, ICS-2000, ICS-1600, ICS-1500, ICS-1100, and ICS-1000 chromatography systems. It is not compatible with the ICS-90 or ICS-900. When ordering an Atlas suppressor for older systems, the DX-600, BioLC, or DX-320 systems must be configured with an ED50A, CD25A, or IC25A detector. The RFC-30 or RFC-10 Suppressor Controller must be ordered to use the Atlas with the earlier versions of detectors.Ordering InformationAnion Atlas Electrolytic Suppressor056116Cation Atlas Electrolytic Suppressor056118
Instrument.com.cn Copyright©1999- 2023 ,All Rights Reserved版权所有,未经书面授权,页面内容不得以任何形式进行复制