Dione CarboPac PA20 碳水化合物分析柱
Dione CarboPac PA20 碳水化合物分析柱没有与Thermo Scientific戴安CARBOPAC?PA20柱牺牲分辨率快速,高效地分离单糖。脉冲安培检测(PAD)相结合,这些强阴离子交换柱在高pH值,无需衍生提供高分辨率的分离。实现在哺乳动物糖蛋白在宽范围的洗脱剂浓度通常发现六个单糖之间基线的分辨率。Dione CarboPac PA20 碳水化合物分析柱订货信息:分析柱CarboPac PA20 Analytical Column (3 x 150 mm)060142CarboPac PA20 Capillary Column (0.4 x 150 mm)072072CarboPac PA20 Fast Sialic Column (3 x 30 mm)076381保护柱CarboPac PA20 Guard Column (3 x 30 mm)060144Borate Trap Column047078Amino Trap Column (3 x 30 mm)060146CarboPac PA20 Capillary Guard Column (0.4 x 35 mm)072073Fast, Sensitive Mono- and Disaccharide AnalysisThe Thermo Scientific Dionex CarboPac? PA20 column line has been expanded to include a new 0.4 × 150 mm capillary column and a new Dionex CarboPac PA20 Fast Sialic Acid column.As with all CarboPac PA20 columns, the new capillary format provides high-resolution separations of mono- and disaccharides with no need for derivatization. The Dionex CarboPac PA20, 0.4 × 150 mm format offers the additional advantages of higher mass sensitivity, lower sample amount requirements, and significantly lower solvent use.The new Dionex CarboPac PA20 Fast Sialic Acid column is ideally suited for the fast analysis of sialic acids in glycoprotein acid hydrolyzates. The Dionex CarboPac PA20 Fast Sialic Acid column accelerates sialic acid determination allowing sample analysis in less than five minutes. The Dionex CarboPac PA20 Fast Sialic Acid column is packed with the same hydrophobic, polymeric, pellicular anion exchange resin as the Dionex CarboPac PA20 column, but in a 3 x 30 mm column format.The Dionex CarboPac PA20 is a strong anion-exchange column that provides high-resolution separations of mono- and disaccharides with no need for derivatization. This column provides baseline resolution between the six monosaccharides commonly found in mammalian glycoproteins over a wide range of eluent concentrations. The Dionex CarboPac PA20 provides slightly different selectivity from either the Dionex CarboPac PA1 or Dionex CarboPac PA10, making it an attractive choice for separating difficult peak pairs.The column of choice for high-sensitivity monosaccharide analysesHighly efficient separations with good resolution between neighboring peaksFast analysis—less than 10 minOptimized resolution of glucosamine/galactose and glucose/mannose peak pairsLower eluent consumptionDoes not require derivatizationThe Dionex CarboPac PA20 consists of 6.5 μm-diameter nonporous beads covered with a fine latex of functionalized Thermo Scientific Dionex MicroBead? resin. This pellicular resin structure permits excellent mass transfer, resulting in high-resolution chromatography and rapid re-equilibration. The performance of each column is verified with a Thermo Scientific Dionex MonoStandard?.Dionex CarboPac PA20 Column for Fast Monosaccharide Analysis SpecificationsDimensionsDionex CarboPac? PA20 Analytical Column:3 × 150 mmDionex CarboPac PA20 Capillary Column:0.4 × 150 mmDionex CarboPac PA20 Fast Sialic Acid Column:3 × 30 mmDionex CarboPac PA20 Guard Column:3 × 30 mmMaximum operating pressure3000 psi (21 MPa)Temperature range4–60 °CRecommended operating temperature: 30 °CTypical operating conditionsTest procedure: Baseline resolution of fucose, galactosamine, glucosamine, galactose, glucose, mannose. Dionex CarboPac PA20 Analytical Column recommended flow rate: 0.5 mL/minDionex CarboPac PA20 Capillary Column recommended flow rate: 8 μL/minDionex CarboPac PA20 Fast Sialic Acid Column recommended flow rate: 0.5 mL/minMobile phase compatibilitypH 0–14 100% compatible with common HPLC solvents and 100% water.Ionic form eluents: sodium hydroxide, sodium acetate.Resin composition6.5 μm-diameter substrate (ethylvinylbenzene 55% crosslinked with divinylbenzene) agglomerated with 130 nm MicroBead? difunctional quaternary ammonium ion (5% crosslinked).Anion-exchange capacityApproximately 65 μeq/column (3 × 150 mm analytical column)Approximately 1.16 μeq/column (0.4 × 150 mm capillary column)Approximately 13 μeq/column (0.3 x 30 mm Fast Sialic Acid column)Column constructionPEEK? with 10-32 threaded ferrule-style end fittings.All components are nonmetallic.Analysis of chocolate syrup using the CarboPac PA20. Sialic acid analysis of bovine fetuin. Effect of hydroxide concentration on monosaccharide elution times. Monosaccharide analysis of rabbit serum using the CarboPac PA20 column. Profiling MAb hydrolysate on the CarboPac PA20 column, with and without an AminoTrap? precolumn.Product Data SheetsCarboPac PA20 Column Data SheetGuidesCarboPac PA20 Analytical Column ManualCarboPac PA20 Capillary Column Product ManualApplicationsAU 180: Direct Determination of Sialic Acids in Glycoprotein Hydrolyzates by HPAE-PADAU 181: Rapid Screening of Sialic Acids in Glycoproteins by HPAE-PADAN 253: HPAE-PAD Determination of Infant Formula Sialic AcidsAN 248: Determination of Lactose in Lactose-Free Milk Products by High-Performance Anion-Exchange Chromatography with Pulsed Amperometric DetectionAB 127: Determination of Carbohydrates in Fruit Juice Using Capillary High-Performance Anion-Exchange Chromatography