当前位置: 仪器信息网 > 行业主题 > >

溴乙烯四氢呋喃溶液

仪器信息网溴乙烯四氢呋喃溶液专题为您提供2024年最新溴乙烯四氢呋喃溶液价格报价、厂家品牌的相关信息, 包括溴乙烯四氢呋喃溶液参数、型号等,不管是国产,还是进口品牌的溴乙烯四氢呋喃溶液您都可以在这里找到。 除此之外,仪器信息网还免费为您整合溴乙烯四氢呋喃溶液相关的耗材配件、试剂标物,还有溴乙烯四氢呋喃溶液相关的最新资讯、资料,以及溴乙烯四氢呋喃溶液相关的解决方案。

溴乙烯四氢呋喃溶液相关的资讯

  • 猪肉中四种硝基呋喃类代谢物残留量的测定 液相色谱串联质谱法
    一.实验目的 本文使用天津博纳艾杰尔科技有限公司的Cleanert PEP-2固相萃取柱、Venusil MP C18色谱柱和AB SCIEX公司的API 4000+质谱仪,遵照中华人民共和国国家标准《猪肉、牛肉、鸡肉、猪肝和水产品中硝基呋喃类代谢物残留量的测定(GB/T 20752-2006)》提供的方法,检测猪肉中的4种硝基呋喃类代谢物残留。 二.实验方法 2.1.样品信息 2.2.样品提取 称取猪肉样品2g(精确到0.01g),置于50m棕色离心管中,加入15ml甲醇-水混合溶液(v:v=2:1),均质1min,8000r/min离心5min 吸取上清液倒掉,残渣中加入2ppb的硝基呋喃类代谢物混合标准品各1ml,混合均匀。 2.3.水解和衍生(注意避光) 向棕色离心管中加入20ml 0.2mol/l的盐酸溶液,涡旋1min使之混合均匀,之后加入0.3ml浓度为0.05mol/L的2-硝基苯甲醛,混匀,于37℃温水中避光衍生16小时。 2.4.净化处理 将衍生后的样品冷却至室温,加入5ml 0.1mol/l的磷酸氢二钾,并用1 mol/l的氢氧化钠溶液调PH约为7.4,混合均匀。之后用8000r/min离心10min,以小于2ml/min的流速过PEP-2小柱(规格为60mg/3ml,用5ml甲醇、5ml水活化),并用10ml的水洗涤固相萃取小柱,然后负压抽干柱子15min。用5ml乙酸乙酯洗脱于20ml棕色瓶中,并在40℃下氮气吹干。 用样品定容溶液(10ml乙腈,0.3ml的乙酸用水稀释至100ml)定容至1ml,充分溶解,并用0.2um滤膜过滤。 2.5.检测方法 色谱柱:Vesusil® MP-C18(2.1× 150mm,5um,100Å ) 质谱仪:API 4000+ 流动相:A:0.1%甲酸的水溶液 B:0.1%甲酸的乙腈溶液 流速:0.2mL/min 表1 梯度洗脱条件 时间(min) A(%) B(%) 0 80 201 80 20 3 50 50 7 25 75 7.1 5 95 10 5 95 10.1 80 20 16 80 20 进样体积:5&mu L 离子源:电喷雾(ESI),正离子模式 扫描方式:多反应监测(MRM) 表2 质谱仪离子源参数 Source/Gas Collision Gas(CAD) 6 Curtain Gas(CUR) 15 Ion Source Gas 1(GS 1) 50 Ion Source Gas 2(GS 2) 50 Ion Spray Voltage(IS) 5500 Temperature(TEM) 600 Interface Heater(ihe) On表3 4种硝基呋喃待测物母离子和子离子参数表 物质名称 保留时间(min) 监测离子对 DP EP CE CXP SEM 8.10 209.1/166.1 51 10 17 10 209.1/192.1 51 10 17 10 AHD 8.30 249.2/134.1 61 10 20 10 249.2/104.1 66 10 31 10 AOZ 8.89 236.2/134.1 61 10 20 10 236.2/104.1 56 10 31 10 AMOZ 3.12 335.3/291.2 46 1019 10 335.5/128.1 46 10 19 10 图1 4种硝基呋喃代谢物总离子 图2 SEM(209/166)质谱图 图3 AOZ(236/134)质谱图 图4 AHD(249/134)质谱图 图5 AMOZ(335/291)质谱图 三.实验结果 0.5ppb猪肉基质加标回收实验结果: 表4 猪肉中0.5ppb加标回收实验结果 名称 1# 2# 3# 平均回收率 RSD AMOZ 109.43% 97.84% 109.75% 105.67% 6.42% SEM 91.81% 88.91% 88.22% 89.65% 2.12% AHD 80.68% 82.11% 77.25% 80.01% 3.12% AOZ 83.94% 80.70% 80.85% 81.83 0.02% 四.实验结论 Agela Cleanert PEP-2、Agela Venusil MP C18和AB SCIEX公司的API 4000+质谱仪用于猪肉中4种硝基呋喃代谢物的检测,性能良好,符合国标文件的要求。 订货信息 产品名称 规格/包装 订货号 定价(元) Cleanert® PEP-2 60mg/3mL,50支/包 PE0603-2 1035.00 Venusil® MP C18 2.1× 150mm,5um,100Å ;1支 VA951502-0 3200.00
  • 猪肉中四种硝基呋喃类代谢物残留量测定(SPE-LC/MS/MS)-依国标
    一.实验目的 本文使用天津博纳艾杰尔科技有限公司的Cleanert® PEP-2固相萃取柱、Venusil® MP C18色谱柱和Qdaura卓睿TM全自动固相萃取仪,遵照中华人民共和国国家标准《猪肉、牛肉、鸡肉、猪肝和水产品中硝基呋喃类代谢物残留量的测定(GB/T 20752-2006)》提供的方法,检测猪肉中的4种硝基呋喃类代谢物残留。 二.实验方法 2.1.样品信息 2.2.样品称取和脱脂 称取猪肉样品2g(精确到0.01g),置于50m棕色离心管中,加入15ml甲醇-水混合溶液(v:v=2:1),均质1min,再用5ml甲醇-水混合溶液洗涤刀头,二者合并8000r/min离心5min,吸取上清液倒掉。 注:为更好的消除基质效应对检测结果造成的影响,可加入同位素内标,采用内标法定量检测。 2.3.水解和衍生(注意避光) 向棕色离心管中加入20ml 0.2mol/l的盐酸溶液,涡旋1min使之混合均匀,之后加入0.3ml浓度为0.05mol/L的2-硝基苯甲醛,混匀,于37℃温水中避光衍生16小时。 2.4.净化处理 将衍生后的样品冷却至室温,加入5ml 0.1mol/l的磷酸氢二钾,并用1 mol/l的氢氧化钠溶液调PH约为7.4,混合均匀。之后用8000r/min离心10min,以小于2ml/min的流速过Cleanert® PEP-2小柱(规格为60mg/3ml,用5ml甲醇、5ml水活化),并用10ml的水洗涤固相萃取小柱,然后负压抽干柱子15min。用5ml乙酸乙酯洗脱于20ml棕色瓶中(此过程可在Qdaura卓睿TM全自动固相萃取仪上完成,仪器方法见附录B)。洗脱液于40℃下氮气吹干。 用样品定容溶液(10ml乙腈,0.3ml的乙酸用水稀释至100ml)定容至1ml,充分溶解,并用0.22µ m滤膜过滤。 2.5.检测方法 色谱柱:Venusil® MP C18(2.1× 150mm,5µ m,100Å ) 质谱仪:API 4000+ 流动相:A:0.1%甲酸的水溶液 B:0.1%甲酸的乙腈溶液 表1 梯度洗脱条件 时间(min) A(%) B(%) 0 80 20 1 80 20 3 50 50 7 25 75 7.1 5 95 10 5 95 10.1 80 20 16 80 20 流速:0.2mL/min 进样体积:5&mu L 离子源:电喷雾(ESI),正离子模式 扫描方式:多反应监测(MRM) 表2 质谱仪离子源参数 Source/Gas Collision Gas(CAD) 6 Curtain Gas(CUR) 15 Ion Source Gas 1(GS 1) 50 Ion Source Gas 2(GS 2) 50 Ion Spray Voltage(IS) 5500 Temperature(TEM) 600 Interface Heater(ihe) On 表3 4种硝基呋喃待测物母离子和子离子参数表 物质名称 保留时间(min) 监测离子对 DP EP CE CXP SEM 8.10 209.1/166.1 51 10 17 10 209.1/192.1 51 10 17 10 AHD 8.30 249.2/134.1 61 10 20 10 249.2/104.1 66 10 31 10 AOZ 8.89 236.2/134.1 61 10 20 10 236.2/104.1 56 10 31 10 AMOZ 3.12 335.3/291.2 46 10 19 10 335.5/128.1 46 10 19 10 三.实验结果 0.5ppb猪肉基质加标回收实验结果: 表4 猪肉中0.5ppb加标回收实验结果 名称 1(%) 2(%) 3(%) 平均回收率(%) RSD(%) AMOZ 109.43 97.84 109.75 105.67 6.42 SEM 91.81 88.91 88.22 89.65 2.12 AHD 80.68 82.11 77.2580.01 3.12 AOZ 83.94 80.70 80.85 81.83 0.02 四、实验结论 规格 订货信息 Qdaura 卓睿&trade 全自动固相萃取 4通道24位
  • Detelogy饲料中兽残抗生素检测前处理解决方案——以硝基咪唑类、硝基呋喃类、硝基喹啉类为例
    据报道“全球每年消耗的抗生素总量90%用在食源动物身上,致使细菌耐药性和药物残留等问题日益突出。”本文以硝基咪唑类、硝基呋喃类、硝基喹啉类为例,针对饲料中兽残抗生素检测提供了高效智能前处理解决方案。本方案适用于饲料中异丙硝唑、甲硝唑、替硝唑、塞克硝唑、卡硝唑、奥硝唑、地美硝唑、罗硝唑8种硝基咪唑类药物,呋喃唑酮、呋喃它酮、呋喃妥因、呋喃西林4种硝基呋喃类药物和卡巴氧、喹乙醇、乙酰甲喹、喹烯酮4种喹啉类药物的前处理方案。本方案适用于畜禽配合饲料、浓缩饲料、添加剂预混合饲料和精料补充料中硝基咪唑类、硝基呋喃类和喹啉类药物的前处理方案。本标准的检出限为0.05 mg/kg,定量限为0.10 mg/kg。实验步骤:一、提取称取试样2 g(精确至.01 g)于50 mL离心管中,准确加入200 mL提取液(甲醇V:乙腈V:超纯水V,3:3:4)用MultiVortex多样品涡旋混合器混合后,水浴超声提取10 min,振荡15 min。8000 rpm离心5 min,取1.00 mL上清液于40℃下用FV64全自动智能氮吹仪吹至近干,残余物用0.1 mol/L磷酸二氢钠溶液5.0 mL溶解,超声10 min,备用。二、净化将HLB固相萃取柱固定于iSPE-864全自动智能固相萃取仪上,固相萃取条件如下:将洗脱液用FV64全自动智能氮吹仪吹干。准确加入60%乙腈溶液1.00 mL溶解残余物,使用MultiVortex多样品涡旋混合器混匀后,超声10 min,过0.22 μm微孔滤膜,供液相色谱串联质谱仪测定。注:操作过程中注意避光,试样上机前酌情稀释,避免造成仪器污染。所用Detelogy智能前处理设备建议选型● 高转速搭载3mm圆周振幅,保证每个样品充分混合● 外观灵巧轻便,主机低重心设计,运行噪声低,进阶实现稳健高转速● 5寸高清触屏,支持手动自动双模式,中英文界面自由切换● 64位高通量,氮吹针自动下降● 支持全自动延时氮吹和延时增压● 10.1寸高清触屏控制,可存方法● 8通道,批量处理64位样品● 自动完成活化、上样、淋洗、氮吹、洗脱等固相萃取全流程
  • 阿尔塔科技推出51种农药混合标准溶液
    主要用途:此标准溶液完全符合国标《食品中农药最大残留限量》(GB2763-2014)的要求,其中的51种农药均在农业部规定的70多种例行监测农残中,可用于同时分析蔬菜水果中51种农业部例行监测的农残的定性与定量。该产品已应用到SCIEX发布的"51种农药检测软件库和方法包 "中,是例行监测解决方案必备品!订货号1ST27019-10M 产品名51种农药混合标准溶液规格10ppm浓度10ug/ml溶剂甲醇包装??1ml/支成分如下:产品号产品名称英文名称CAS#1ST21058多菌灵Carbendazim10605-21-71ST20297啶虫脒Acetamiprid135410-20-71ST20298吡丙醚Imidacloprid138261-41-31ST20001毒死蜱Chlorpyrifos2921-88-21ST20350噻虫嗪Thiamethoxam153719-23-41ST21145烯酰吗啉Dimethomorph110488-70-51ST21189苯醚甲环唑Difenonazole119446-68-31ST21226腐霉利Procymidone32809-16-8????1ST20305氟虫腈Fipronil120068-37-31ST20438三唑磷Triazophos24017-47-81ST20155丙溴磷Profenofos41198-08-71ST22249二甲戊灵Pendimethalin40487-42-11ST20271克百威Carbofuran1563-66-2??1ST20170?辛硫磷Phoxim14816-18-3??1ST21164异菌脲Iprodione36734-19-7?1ST20182敌百虫Trichlorphon52-68-61ST21247咪鲜胺Prochloraz67747-09-51ST20348氟啶脲Chlorfluazuron71422-67-81ST25000阿维菌素Abamectin71751-41-21ST20167氧乐果Omethoate1113-02-61ST20345除虫脲Diflubenzuron35367-38-51ST20127甲基异柳磷Isofenphos-methyl?99675-03-31ST20097敌敌畏Dichlorvos62-73-71ST20093甲胺磷Methamidophos10265-92-61ST20449灭多威Methomyl16752-77-51ST20144乙酰甲胺磷Acephate30560-19-11ST21161嘧霉胺Pyrimethanil???53112-28-01ST20277甲萘威Carbaryl63-25-21ST20273涕灭威亚砜Aldicarb-sulfoxid?1646-87-31ST20375涕灭威Aldicarb116-06-31ST20098乐果Dimethoate60-51-51ST202593-羟基-呋喃丹 3-羟基克百威Carbofuran-3-hydroxy16655-82-61ST20266涕灭威砜 涕灭氧威Aldicarb sulfone1646-88-41ST20124甲拌磷Phorate298-02-21ST20140甲基对硫磷Parathion-methyl298-00-01ST20111杀螟硫磷Fenitrothion 122-14-51ST20065倍硫磷Fenthion55-38-91ST20173水胺硫磷Isocarbophos24353-61-5??1ST20434对硫磷Parathion56-38-21ST21202三唑酮Triadimefon43121-43-3?1ST20094二嗪磷Diazinon333-41-51ST20349灭幼脲Chlorobenzuron Chlorbenzuron57160-47-11ST20189亚胺硫磷Phosmet732-11-61ST20168马拉硫磷Malathion121-75-5?1ST20406哒螨灵Pyridaben96489-71-31ST20172伏杀硫磷Phosalone2310-17-0??1ST21157嘧菌酯Azoxystrobin131860-33-81ST20288甲氨基阿维菌素苯甲酸盐Emamectin Benzoate155569-91-81ST20222甲氰菊酯Fenpropathrin39515-41-81ST20210联苯菊酯Bifenthrin82657-04-31ST20396虫螨腈Chlorfenapyr122453-73-0附:SCIEX——蔬菜水果中51种农业部例行监测农残的LC-MS/MS分析方法Figure 1. 韭菜基质中0.01 mg/kg农药的色谱图51种农药:多菌灵、啶虫脒、吡虫啉、毒死蜱、噻虫嗪、烯酰吗啉、苯醚甲环唑、腐霉利、氟虫腈、三唑磷、丙溴磷、二甲戊灵、克百威、辛硫磷、异菌脲、敌百虫、咪鲜胺、氟啶脲、阿维菌素、氧乐果、除虫脲、甲基异柳磷、敌敌畏、甲胺磷、灭多威、乙酰甲胺磷、嘧霉胺、甲萘威、涕灭威亚砜、涕灭威、乐果、3-羟基克百威、涕灭威砜、甲拌磷、甲基对硫磷、杀螟硫磷、倍硫磷、水胺硫磷、对硫磷、三唑酮、二嗪磷、灭幼脲、亚胺硫磷、马拉硫磷、哒螨灵、伏杀硫磷、嘧菌酯、甲氨基阿维菌素苯甲酸盐、虫螨腈、甲氰菊酯、联苯菊酯
  • 【国抽应对】水产品中硝基呋喃代谢物的检测(GB 31656.13-2021)难点解析
    近期,2022版食品安全监督抽检实施细则发布,其中指定GB 31656.13-2021《水产品中硝基呋喃类代谢物多残留的测定 液相色谱-串联质谱法》,为淡水鱼、淡水虾、海水鱼等基质硝基呋喃代谢物的检测标准(表1)。 表1 2022版国抽细则水产品中硝基呋喃代谢物检测项目01标准亮点 ▶ 细化了适用范围。适用于鱼、海参、鳖等水产品可食组织中硝基呋喃类代谢物 AOZ、AMOZ、AHD 和 SEM 残留量的测定;虾和蟹等甲壳类可食组织中 AOZ、AMOZ和 AHD的测定,这里不包括SEM,因为此类基质中,可能存在SEM这种内源性物质,从而导致结果假阳性。▶ 提高了HCl溶液的浓度,为0.5mol/L,水解更彻底。▶ 提高了提取、净化步骤中的离心转速,分别为6000、14000r/min,简化了前处理步骤。▶ 采用1次提取即可,更高效。 众所周知,硝基呋喃代谢物检测在兽残检测中属于较难做的项目,下面我们也来梳理一下实际做样过程中应该注意哪些方面。 02注意事项 ▶ 部分标准品(如SEM)较难溶,可借助超声波助溶。▶ 2-硝基苯甲醛现配现用,标准品与样品同步衍生。▶ 衍生后的目标物不稳定,前处理过程注意避光。▶ 注意pH的调节,pH为7.0-7.5时,目标物提取效果好。▶ 注意SEM的假阳性问题。除了上述可能存在内源性物质干扰外,还有几个方面可能造成SEM的假阳性——塑料包装材料中使用的偶氮甲酰胺,在高温下受热可分解产生SEM;采用次氯酸钠对水产品进行消毒和漂白也可以产生SEM。 小编认为,注意了以上细节,硝基呋喃的检测应该不会有太大问题啦。接下来,再为大家介绍岛津的应对方案。 03鱼肉中硝基呋喃类代谢物的测定岛津LCMS-8045三重四极杆液质联用仪 ▶ 检测仪器:岛津LCMS-8045▶ 色谱柱:Shim-pack GISS C18 Column(2.1 mm I.D.×100 mm L., 1.9 μm)▶ 流动相:A相:(0.01%甲酸)水, B相:(0.01%甲酸)乙腈▶ 流速:0.50 mL/min▶ 柱温:40℃▶ 进样体积:10 µL▶ 洗脱方式:梯度洗脱,初始比例10%B 表2 通用梯度洗脱程序图1 标准样品的MRM色谱图(0.5 ng/mL) 表3 校准曲线参数图2 鱼肉加标样品色谱图(1.0ng/mL) 本文内容非商业广告,仅供专业人士参考。
  • 岛津水产品中硝基呋喃类代谢物残留LCMSMS检测方案
    硝基呋喃类药物(Nitrofurans)是一类合成的抗菌药物,它们作用于微生物酶系统,抑制乙酰辅酶A,干扰微生物糖类的代谢,从而起抑菌作用。目前在医疗上应用较广者有:呋喃西林、呋喃妥因和呋喃唑酮。呋喃西林只供局部应用,后两者则可供系统治疗应用。目前在医疗上应用较广者有:呋喃西林、呋喃妥因和呋喃唑酮。呋喃西林只供局部应用,后两者则可供系统治疗应用。 硝基呋喃类药物很不稳定,很容易生成代谢物。硝基呋喃类药物在动物体内迅速分解产生代谢物,代谢物在体内与细胞膜蛋白结合成结合态。由于代谢物比较稳定也有致癌作用,所以在食品安全的检测中检测硝基呋喃代谢物。常见的硝基呋喃代谢物的衍生物有如下四种,包括:3-氨基-2-恶唑酮(AOZ)、5-吗啉甲基-3-氨基-2-恶唑烷基酮(AMOZ)、1-氨基-乙内酰脲(AHD)和氨基脲(SEM)。 本方案建立了一种使用岛津超高效液相色谱仪LC-30A和三重四极杆质谱仪LCMS-8030联用检测水产品中硝基呋喃类代谢物的残留量的测试方法。样品经处理后,用超高效液相色谱LC-30A在4.0 min内完成分离,三重四极杆质谱仪LCMS-8030进行定量分析。对四种硝基呋喃类代谢物残留的线性、精密度、检出限(LOD)、定量限(LOQ)进行了验证。3-氨基-2-恶唑酮(AOZ)、5-吗啉甲基-3-氨基-2-恶唑烷基酮(AMOZ)、1-氨基-乙内酰脲(AHD)和氨基脲(SEM)在1~200 &mu g/L内线性良好,相关系数均大于0.999;分别用浓度为1 µ g/L、10 µ g/L和50 µ g/L的混合标准溶液进行了精密度实验,实验结果表明连续6次进样保留时间和峰面积相对标准偏差分别在0.28 ~ 0.07%和4.76 ~ 1.68%间,仪器精密度良好。满足《GB/T 21311-2007 动物源性食品中硝基呋喃类药物代谢物残留量检验方法 高效液相色谱串联质谱法》的检测要求。 了解详情,请点击《超高效液相色谱三重四极杆质谱联用法测定水产品中硝基呋喃类代谢物残留》。 关于岛津 岛津企业管理(中国)有限公司是(株)岛津制作所为扩大中国事业的规模,于1999年100%出资,在中国设立的现地法人公司。 目前,岛津企业管理(中国)有限公司在中国全境拥有13个分公司,事业规模正在不断扩大。其下设有北京、上海、广州、沈阳、成都分析中心;覆盖全国30个省的销售代理商网络;60多个技术服务站,构筑起为广大用户提供良好服务的完整体系。 岛津作为全球化的生产基地,已构筑起了不仅面向中国客户,同时也面向全世界的产品生产、供应体系,并力图构建起一个符合中国市场要求的产品生产体制。 以&ldquo 为了人类和地球的健康&rdquo 为目标,岛津人将始终致力于为用户提供更加先进的产品和更加满意的服务。 更多信息请关注岛津公司网站www.shimadzu.com.cn/an/ 。
  • 硝基呋喃及其代谢物检测三大利器!
    硝基呋喃类抗菌药物是一种广谱抗生素,包括了硝基呋喃唑酮、呋喃它酮、呋喃妥因、呋喃西林,曾广泛应用于水产养殖业,用来治疗由大肠杆菌或沙门氏菌所引起的肠炎、疥疮、赤鳍病、溃疡病等。这类化合物对光敏感,衰减快,其母体化合物在动物体内及其产品中代谢很快,但其代谢物以蛋白结合物的形式存在可残留较长时间,目前各国均将硝基呋喃代谢物作为指示硝基呋喃类药物残留的标示物。因硝基呋喃类药物及其代谢物具有相当大的毒副作用,世界上绝大部分国家规定在食用动物组织中不允许有硝基呋喃药物残留;美国21CFR530.41规定食源性动物禁止食用呋喃唑酮和呋喃妥因;欧盟EEC2377/90将硝基呋喃类药物及其代谢物列为A类禁用药物;我国也于2002年颁布了禁用硝基呋喃类抗生素的禁令。2017年3月9日,农业部办公厅发布关于开展2017年水产品质检机构检测能力验证工作的通知,提到硝基呋喃类代谢物的检测方法依据为《水产品中硝基呋喃类代谢物残留量的测定-液相色谱-串联质谱法》(农业部783号公告-1-2006),使用内标法定量。First Standard® 推出硝基呋喃及其代谢物检测三大利器,确保您的实验全程无忧!它们是:4种硝基呋喃混标帮助您节省实验前的准备时间,浓度100ppm,可配制多组工作液Cat.No中文名称规格/CAS#1ST9262-100M4种硝基呋喃混标100ppm1ST4207呋喃唑酮67-45-81ST4208呋喃它酮139-91-31ST4209呋喃妥因67-20-91ST4210呋喃西林59-87-04种硝基呋喃类内标溶液许多客户反馈内标难找,我们这里4种内标齐全,1支混标搞定!Cat.No中文名称规格/CAS#1ST9230-100M4种硝基呋喃类内标混标100ppm1ST4226氨基脲-13C,15N2盐酸盐1173020-16-01ST4203D53-氨基-5-吗啉甲基-2-噁唑烷酮-d51017793-94-01ST4201D43-氨基-2-噁唑烷酮-d41188331-23-81ST4204C31-氨基-2-乙内酰脲-13C3957509-31-84种硝基呋喃代谢物衍生化混标不用担心标品衍生不成功或衍生不完全影响实验,我们提供衍生好的混标!Cat.No中文名称规格/CAS#1ST9283-100ppm4种硝基呋喃代谢物衍生化混标(以代谢物计)100ppm1ST42152-NP-呋喃妥因代谢物623145-57-31ST42172-NP-呋喃它酮代谢物183193-59-11ST42192-NP-呋喃唑酮代谢物19687-73-11ST42212-NP-呋喃西林代谢物16004-43-6如需订购请联系天津阿尔塔科技有限公司或各地经销商。
  • 全自动乌氏黏度计在聚偏二氯乙烯PVDC材料中的应用
    聚偏二氯乙烯(Polyvinylidene chloride)简称PVDC,是以偏二氯乙烯(VDC)单体为主要成分的共聚物。一种软化温度在160-200℃的热塑性聚合物,具有头尾相连的线性聚合链结构。PVDC是一种阻湿、阻氧皆优的高阻隔性能包装材料,由于其对称的分子结构和疏水基氯的存在,是一种高结晶性聚合物,阻隔性能好且不会随湿度而改变。PVDC最大优点是对众多的气体或水汽有很高的阻隔性,是当今世界上塑料包装中综合阻隔性能较好的包装材料。基于PVDC的优良特性,其应用领域十分广泛。所以在生产质量控制方面的要求也非常严格。不管是PVDC材料的黏度、水分等项目的检测上,其检测数据的重复性,准确性要求甚高。乌氏黏度计一直以来都是测试黏度的最常用的经典测试工具。现在的全自动乌氏黏度计不仅在操作流程上实现全自动化的模式,其在测试数据上也更加精确。IVS800全自动黏度测量系统测试流程称样用万分之一天平称取聚偏二氯乙烯(PVDC)样品,放入到溶样瓶中,用DP25自动配液器(移液精度≤0.1%)移取定量四氢呋喃溶液到溶样瓶中;融样将溶样瓶放入P12中旺聚合物溶样器中(可多个溶样同时进行溶解),采用磁力搅拌的方式,按照规定的温度、时间溶样;黏度测试将装置聚偏二氯乙烯(PVDC)试样的溶样瓶放入已设置好所需水槽温度(25±0.01℃)的IVS800全自动乌氏黏度计样品盘中,启动测试功能,自动得出测试结果; 测试结果IVS800全自动乌氏黏度计连接电脑端,可自动得出测试结果并进行数据储存,便于多样化黏度数据分析; 清洗黏度管黏度管固定在IVS800全自动乌氏黏度计恒温水槽中,无需拆装取出,可自动清洗、自动排废、自动干燥。
  • 英国食品安全局公布第五次丙烯酰胺和呋喃调查报告
    英国食品安全局(FSA)近日在其第五次也是最近一次对英国一系列食品中的丙烯酰胺(acrylamide)、呋喃(furan)及加工污染水平的调查报告中公布了中期业绩。   基于2011年11月到2012年12月收集的约300种产品样本,调查给出了英国零售食品中丙烯酰胺和呋喃的范围水平。   报告中的丙烯酰胺和呋喃水平并不会增加人类健康的风险,因此机构没有必要修改针对消费者的建议。   与往年一样,此次丙烯酰胺和呋喃的调查结果也将被送至欧洲食品安全局(EFSA)用于收集、趋势分析,对于呋喃,将进行风险评估。   2012-2013年的调查报告将于2014年公布。如有可能,报告将包括该机构自2007年收集的所有英国的丙烯酰胺和呋喃水平调查数据的统计趋势分析。
  • LGC宣布并购o2si 标准溶液产品线进一步增强
    2016年11月7日,英国LGC公司宣布其正式并购o2si。o2si公司位于美国南卡莱罗纳州的查尔斯顿(Charleston),是全球知名的有机及无机标准品生产者。该并购增强了LGC应用于食品和环境分析检测领域的标准物质产品组合。  LGC全球标准品部门董事总经理Euan O’Sullivan评价道:“我们欢迎o2si加入标准品部门。在LGC现有的位于北美及德国工厂的基础上,o2si的加入很好地补充了我们的研发生产能力,强化了LGC在有机标准溶液领域的专业度,同时快速反应的标准品定制服务也极大地提高了LGC的竞争力。我们期待和新同事们共同努力,更好地服务于全球食品环境领域用户。”  o2si公司技术总监Dan Biggerstaff博士说:“我们很高兴加入LGC,这将极大增强我们的产品供应及客户服务能力。LGC在全球标准品领域具有权威地位和一系列原创技术,我们很自豪能够加入LGC大家庭,成为其中一员。我也深信这将为o2si员工提供更广阔的发展空间。自1997年创立以来,o2si专注于提供有创新性,经济快捷的溶液型产品,得益于我们出色的技术能力和世界级的服务,我们很好地满足了客户的需求。通过将LGC已有的有机固体单标和o2si有机液标及定制标品结合起来,我们期待为客户提供一如既往的优质服务以及品种齐全的产品线。”  o2si产品符合ISO 17025、ISO 导则 34 以及 ISO 9001要求。o2si位于美国南卡莱罗纳州查尔斯顿(Charleston)的生产基地将继续保留。  LGC总部位于英国伦敦Teddington,通过其位于美国缅因州Cumberland Foreside,新罕布什尔州Manchester,德国Luckenwalde和Augsburg的生产中心,LGC持续为全球市场供应种类繁多的标准物质。这些基地研发生产的有机和无机标准品广泛应用于包括医药,食品,环境,冶金,石油化工,临床检验等分析检测的各个领域。  ---------------------------------------------------------------------  关于LGC  LGC集团是全球领先的生命科学计量分析和检测公司,在成长市场具有领导地位。LGC提供包括标准物质,能力验证,基因分析仪器和试剂,以及专业的样品测试和解析在内的一系列计量分析产品和服务,为公众安全,健康,和安保提供有力支持。LGC的服务对象所涉甚广,包括医药卫生,农业生物技术,临床诊断,食品安全,环境保护,政府机构和学术科研等诸多领域。  LGC总部位于伦敦,拥有2000多名员工,在全球22个国家设有分支机构。LGC的业务单元获得众多国际认证,例如ISO/IEC 17025, ISO 13485, GMP, GLP and ISO Guide 34等。  LGC的历史可以追溯到1842年,迄今已成功运作了170余年。在过去100多年中,LGC一直是“英国政府化学家”的依托机构,而且目前行使英国国家计量院化学和生物计量所的职能。LGC于1996年转制为公司化运作,KKR基金现拥有其所有权。
  • 硝基呋喃检测,岛津LCMSMS带您乘风破浪!
    导 读 农业农村部、国家卫生健康委员会和国家市场监督管理总局公告2019年第114号《食品安全国家标准 食品中兽药最大残留限量》规定了267种(类)兽药在畜禽产品、水产品、蜂产品中的2191项残留限量及使用要求。对此,岛津公司发布了《GB 31650-2019食品中兽药最大残留限量及兽残检测标准应对解决方案》,方案包括了以下四个部分:标准解读、兽药残留限量技术要求、GB 31660.1~9-2019兽药残留检测前处理方法包和9项兽药残留检测的应用报告,期望能给相关行业的用户在兽药残留分析上带来便利。 虽然《食品中兽药最大残留限量》并没有收载禁用药物及化合物清单,这些化合物在2020年1月6日颁布的中华人民共和国农业农村部公告第250号有明确规定。大家熟悉的β-受体激动剂、氯霉素、类固醇激素及硝基呋喃类都属于禁止使用的药物,在动物性食品中不得检出。而硝基呋喃类药物(Nitrofurans)作为一类合成的抗菌药物,被广泛应用于畜禽水产品的养殖过程中。 什么是硝基呋喃类药物 硝基呋喃主要包括呋喃唑酮、呋喃西林、呋喃它酮和呋喃妥因,具有抗菌消炎作用。硝基呋喃类的原形药物在畜禽和动物体存留时间很短,很快就转化为分子量较小的代谢产物,硝基呋喃类药物及其代谢物对人体均有致癌、致畸的副作用。代谢产物与组织蛋白质紧密结合,以结合态形式在体内残留较长时间,所以在食品安全检测中检测硝基呋喃代谢物。呋喃唑酮、呋喃西林、呋喃它酮和呋喃妥因的代谢物分别为3-氨基-2-恶唑酮(AOZ)、氨基脲(SEM)、5-吗啉甲基-3-氨基-2-恶唑烷基酮(AMOZ)和1-氨基-乙内酰脲(AHD)。结合态的样品经盐酸水解,邻硝基苯甲醛过夜衍生后采用高效液相色谱串联质谱检测。 岛津解决方案 根据GB/T 21311-2007《动物源性食品中硝基呋喃类药物代谢物残留量检测方法 高效液相色谱/串联质谱法》中规定的硝基呋喃测定低限0.5 μg/kg的要求,岛津多款三重四极杆液质联用仪均能轻便应对。 LCMS-8045LCMS-8050LCMS-8060 小龙虾中硝基呋喃检测 作为夏季必备的解暑神器,小龙虾可以称得上是最令人喜爱的美食。五香的、蒜蓉的、麻辣的… … 好吃到根本停!不!下!来!但是小龙虾也是一直充满争议,食品安全的新闻层出不穷。小龙虾真如传言般恐怖吗?小编参照GB/T 21311-2007中前处理方法,使用超高效液相色谱-三重四极杆质谱LCMS-8045分析了网红小龙虾中硝基呋喃代谢物的残留情况。 混合基质标准品的MRM色谱图(1 ng/mL) 在空白基质中加标,配制0.5,1,2,5和10 ng/mL的混合基质标准工作液,按上述条件进行测定。SEM、AHD、AOZ和AMOZ分别以13C15N-SEM、13C-AHD、D4-AOZ和D5-AMOZ为内标物,以浓度比为横坐标,峰面积比为纵坐标,内标法制作校准曲线,结果显示,各化合物在相应浓度范围内线性和准确度良好,痕量硝基呋喃代谢物无所遁形。 实际样品分析 在某小龙虾样品中检出氨基脲(SEM)残留,浓度为2.75 μg/kg。 小龙虾营养丰富,近年来在中国已经成为重要的经济养殖品种,其食品安全问题备受重视。采用岛津超高效液相色谱仪LC-40和三重四极杆质谱仪LCMS-8045联用,可以很好的对小龙虾中硝基呋喃代谢物进行检测,为您的大快朵颐把好第一关。 岛津长期以来一直密切关注国内外食品和药品安全,积极应对,及时提供全面、快速有效的整体解决方案。为了更好地帮助广大用户开展兽药残留分析检测,岛津推出了《GB 31650-2019食品中兽药最大残留限量及兽残检测标准应对解决方案》和《LC-MS/MS兽药分析方法包》,包含445种兽药化合物的中英文名称、分子式、质量数、CAS编号、MRM分析参数等化合物信息以及含类别划分的所有兽药化合物独立方法,用户可根据实际分析情况直接查找化合物相关参数或调用方法,灵活多变地快速实现多组分同时分析。 撰稿人:骆丹
  • 质谱技术进展:低温CE-MS应用于溶液内标记氢氘交换质谱
    大家好,本周为大家分享一篇发表在Analytical Chemistry上的文章,Zero-Degree Celsius Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry1,文章的通讯作者为乌普萨拉大学的Erik T. Jansson博士。  氢氘交换质谱(HDX-MS)适用于研究蛋白质在溶液中的动力学和相互作用,其能够快速分析非变性蛋白中位于蛋白表面的氨基酸序列,广泛应用于蛋白动态表位、活性位点的表征。HDX-MS平台通过低温UPLC分离提供自动化、在线的样品处理和分析。目前,HDX-MS装置的工作流程主要基于Peltier冷却的超高效液相色谱(UPLC)模块的LC-MS方法,但该系统价格昂贵,成本较高,并且在低温条件下,流动相粘度增加导致高背压(可达-20,000 psi),降低了LC的分离效率。而毛细管电泳(CE)在HDX领域有着更好的应用潜力。CE是一种成熟的分离多种类型分子的方法,在蛋白质组学研究中具有独特的价值。CE基于分析物在电场中的不同迁移率进行分离,分离速度取决于分析物的尺寸和电荷。20世纪90年代初,CE-MS开始应用于肽段水平的蛋白质和蛋白质复合物的分析。自此,CE-MS在多肽和蛋白异质体的检测中就显示出比反相LC-MS高10~100倍的灵敏度。近年来,HDX-MS领域的研究人员也聚焦于探究CE用于HDX-MS工作中的潜在优势。本文利用熔融硅毛细管电泳在零摄氏度下完成了氘代肽段和蛋白的淬灭、酶切和分离,该平台具有较好的成本效益,易于装配于任何MS。  CE装置的主要配件包括丙烯酸气密匣(图1A)、毛细管液相分离装置(图1C)和P-727聚醚醚酮三通组件(图1D)。丙烯酸气密匣用于接收N2,内部放有一个不锈钢小瓶装纳氘代背景电解液,能够允许高电压传导到分离毛细管。P-727聚醚醚酮三通组件联通高压电源和N2源,提供分离电压和N2,在毛细管出口产生离子。  图1.Peltier冷却CE外壳+进样槽的结构。(A) 丙烯酸气密匣。(B) Peltier冷却单元所粘附的铝壳体的截面。(C) 毛细管液相分离装置。(D) 同轴三通阀nano电喷雾针。  完成该毛细管平台(图1)的加工和组装后,作者评估了其性能,并将其与先前在微芯片电泳装置上发表的报道进行了比较。首先是峰值容量的评估。使用血管紧张素II(ATII)和甲硫啡肽(ME)作为分离标记的淬灭肽标准品,在0 ℃下,以1 % FA、25% ACN (BFS毛细管)和10% HAc(LPA毛细管)组成的氘代背景电解液(BGE)计算峰容量。与BFS毛细管相比,LPA毛细管除了峰容量值增加外,其序列覆盖率也明显增加。作者比较了0 ℃ CE到0 ℃ LC和微芯片电泳的峰容量值。结果显示,CE的上峰容量虽小于微芯片电泳方法,但序列覆盖率更高。而与LC相比,CE的峰值容量大大提高。  氘质子在淬灭时和分析时中的回交(BE)也是HDX实验重点考察的因素之一。作者使用缓激肽(BK)、ATII和ME作为肽标准品对BE进行了评估。在0 ℃、20 kV的条件下对BFS毛细管和LPA毛细管分别进行测试。结果表明,ATII在BFS和LPA毛细血管上的BE分别为20 %和34 %。ATII在LPA毛细管上的BE值与已报道的商业和实验室改装的UPLC平台的数据(28~36 %)相似,而在BFS毛细管上则接近直接进样完全氘代标准品达到的BE水平。此外,由于注入到毛细管中的样品量与LC所使用的样品量相比很低,在检测的质谱中没有出现任何残留的迹象。  作者对溶液中牛血红蛋白(Hb)进行了HDX,随后又进行了淬灭、胃蛋白酶酶切、低温毛细管电泳分离与质谱(MS)检测。图2显示了根据Kyte-Doolittle疏水性指数选择的6个肽段在不同分离条件下相应的电泳图谱和氘代速率。从图中可以看出,LPA毛细管上分离的肽段峰形更对称,信号强度比BFS毛细管上高一个数量级左右。与BFS毛细管相比,LPA涂层的毛细管整体的氘标记保留绝对值较低,但氘代速率没有检测到差异。虽然BFS毛细管迁移时间更快,但由于BFS毛细管在样品进样之间需要更多的冲洗步骤,因此分析时间比使用LPA毛细管要长。  图2.强度归一化的提取离子电泳图谱,显示了BFS和LPA毛细血管之间迁移时间的差异,以及标记Hb的消化性中的6个代表性肽的HDX动力学图。橙色的迹线显示了使用BFS毛细管分离的结果,紫色的迹线显示了使用LPA涂层毛细管分离的结果。肽段序列的注释及其对应的Kyte-Doolittle疏水性指数显示在右方。(左)在500 s标记时间点显示了代表性的峰形和迁移时间。(右)BFS毛细管中的氘代保留更高。误差棒表示一个标准差,每个时间点n = 3。有些多肽在所有孵育时间内只存在于LPA涂层中,因此上述六个面板其中的两个面板没有在BFS毛细管中的痕迹。α 136 - 141在BFS毛细管上分离的特定样品在500 s时间点显示,但在以后的时间点没有足够的质量,从最终的数据集中省略,因此HDX动力学图不包括该肽段。β 35 - 40没有被检测到,也未被包括在HDX动力学图中。  最后,本文研究了HDX CE-MS平台在表征结构相关信息方面的作用。作者比较了非变性条件下的Hb样品与用6 M尿素置于变性条件下的Hb样品的相对氘代值。研究发现,在非变性状态下更容易受到HDX保护的位点与Hb亚基的相互作用位点相吻合。具体来说,α-Hb上的R32-Y43和L92-D127以及β- Hb上的R29-E42和D98-Q130与这两个单体相互结合的位置相吻合。数据显示(图3),与局部区域的尿素暴露状态相比,Hb的非变性状态对HDX的敏感度降低。这一发现验证了该方法可作为结构蛋白质组学研究的潜在工具——能够表征分子结合和构象动力学,如蛋白质-配体相互作用中遇到的问题。  图3. Hb的HDX数据在PDB 1FSX上的映射。在非变性条件下用D2O标记的Hb与用6 M尿素变性后标记的Hb进行比较。颜色刻度表示50,000 s氘掺入后,天然/尿素D吸收量的比值。  总的来说,本研究提供了低温CE - MS应用于溶液内标记HDX的理论证明。尽管BFS毛细管提供了快速的肽段分离和标记肽段的最小氘损失,但研究结果表明LPA涂层的毛细管在HDX CE - MS中更有优势。有很多途径能够实现该平台的进一步优化,包括但不限于BGE优化(pH、有机质含量、浓度)、浓缩/脱盐步骤、固定化/嵌入式蛋白酶消化、升级Peltier元件以实现更低温的分离、集成无鞘电喷雾界面、交替毛细管涂层和评估更长或更短的毛细管。进一步研究蛋白质化学中常见的盐和溶质分离的耐受性也将是未来优化的一个重点。  撰稿:陈凤平  编辑:李惠琳,罗宇翔  文章引用:Zero-Degree Celsius Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry  参考文献  1. Aerts, J. T. Andren, P. E. Jansson, E. T., Zero-Degree Celsius Capillary Electrophoresis Electrospray Ionization for Hydrogen Exchange Mass Spectrometry. Anal. Chem. 2022.
  • 上海安谱推出环境比武24种挥发性有机物标准溶液
    根据环办[2010]72号文件《关于举办第一届全国环境监测专业技术人员大比武的通知》,环境保护部、人力资源社会保障部、全国总工会决定共同举办第一届全国环境监测专业技术人员大比武,大比武项目包括环境监测理论考试和现场操作,其中现场操作包括以下5个项目:  1.顶空气相色谱-质谱法测定24种挥发性有机物(定性分析)  2.顶空气相色谱-质谱法测定24种挥发性有机物(定量分析)  3.容量法测定氯离子  4.光度法测定可溶性正磷酸盐  5.原子荧光光度法测定砷和汞  项目1和项目2的目标化合物包括:三氯甲烷、四氯化碳、三溴甲烷、二氯甲烷、1, 2-二氯乙烷、环氧氯丙烷、氯乙烯、1, 1-二氯乙烯、1, 2-二氯乙烯、三氯乙烯、四氯乙烯、氯丁二烯、六氯丁二烯、苯乙烯、苯、甲苯、乙苯、邻二甲苯、间二甲苯、对二甲苯、异丙苯、氯苯、1, 2-二氯苯、1, 4-二氯苯。  为配合此次环境监测大比武,上海安谱科学仪器有限公司特定做24种挥发性有机物混合标准溶液,产品信息如下:  货号:CDGG-122768-03-1ml  名称:24种挥发性有机物 标准品  说明:共25组分,因为1,2-二氯乙烯有顺反异构体。  溶剂:甲醇  规格:1ml  价格:1200元  成分:序号英文中文CAS#浓度1chloroform三氯甲烷67-66-3100ug/ml2carbon tetrachloride四氯化碳56-23-5100ug/ml3bromoform溴仿75-25-2100ug/ml4methylene chloride二氯甲烷75-09-2100ug/ml51,2-dichloroethane1,2- 二氯乙烷107-06-2100ug/ml6epichlorohydrin环氧氯丙烷106-89-8500ug/ml7vinyl chloride氯乙烯75-01-4100ug/ml81,1-dichloroethylene1,1- 二氯乙烯75-35-4100ug/ml9trans-1,2-dichloroethylene反式-1,2-二氯乙烯156-60-5100ug/ml10cis-1,2-dichloroethylene顺式-1,2-二氯乙烯156-59-2100ug/ml11trichloroethylene三氯乙烯79-01-6100ug/ml12tetrachloroethylene四氯乙烯127-18-4100ug/ml13chloroprene2- 氯-1,3- 丁二烯126-99-8100ug/ml14hexachlorobutadiene六氯丁二烯87-68-3100ug/ml15styrene苯乙烯100-42-5100ug/ml16benzene苯71-43-2100ug/ml17toluene甲苯108-88-3100ug/ml18ethylbenzene乙苯100-41-4100ug/ml19o-xylene邻二甲苯95-47-6100ug/ml20m-xylene间二甲苯108-38-3100ug/ml21p-xylene对二甲苯106-42-3100ug/ml22isopropylbenzene异丙苯98-82-8100ug/ml23chlorobenzene氯苯108-90-7100ug/ml241,2-dichlorobenzene1,2- 二氯苯95-50-1100ug/ml251,4-dichlorobenzene1,4- 二氯苯106-46-7100ug/ml如需订购,请咨询上海安谱科学仪器有限公司,电话021-54890099。产品信息下载:www.instrument.com.cn/Quotation/Manual/1165695.pdf
  • 稀释溶液的SAXS测量
    对溶解酵素溶液进行SAXS测试,可计算其回转半径(Rg) 和粒子间距离分布函数(PDDF)。 介绍 小角X射线散射(SAXS)是目前用来研究生物体系和更具体蛋白质溶液的众所周知的技术。SAXS能够测定大分子的形貌结构 ,即通过对所研究的蛋白质进行包膜重建。采集标准溶菌酶蛋白数据,来定义其Rg 和 PDDF。 测量&结果 利用Xenocs毛细管流动样品池测量浓度分别为1.5、3.0 和 5.0 mg/ml样品溶液,缓冲液为40 mM醋酸和50mM pH 4.0的NaCl。 表1. 溶解酵素的回转半径取决于浓度及曝光时间。 利用PRIMUS1软件计算得到结构参数Rg。表1记录了不同曝光时间下得到的各浓度样品的数据。数据与同步辐射得到的Rg = 1.43 nm2高度一致。短短10分钟的曝光时间就足以确定这些基本的结构参数。 PRDF p(r)是使用GNOM1软件计算得到。从图1中可以看到,不同浓度下得到的曲线重叠,这证明了低浓度样品测试可以采集到一致的数据。图1. 浓度为1.5, 3.0和5.0 mg/ml样品的PDDF。曝光时间为30分钟。图2. 浓度为5mg/ml样品的PDDF。曝光时间为10分钟和30分钟。 图2显示了浓度为5mg/ml时两种不同曝光时间的比较结果。这些曲线基本重合,说明了10min的曝光时间足以提供相关数据。 深入研究 Nano-inXider完全集成了Xenocs纯净光技术,可以对高度稀释体系进行精确的生物大分子研究。此外,Xenocs低噪音流动样品池的使用降低了容器散射,进一步推动了BioSAXS在实验室中测量的极限。
  • 中/美/欧/日四大药典溶液颜色检查规范 --参考与比较
    中/美/欧/日四大药典澄清度检查规范-中英双译中国药典20200902 澄清度检查法澄清度检查法系将药品溶液与规定的浊度标准液相比较,用以检查溶液的澄清度。除另有规定外,应采用第一法进行检测。品种项下规定的“澄清”,系指供试品溶液的澄清度与所用溶剂相同,或不超过0.5号浊度标准。“几乎澄清”,系指供试品溶液的浊度介于0.5号至1号浊度标准液的浊度之间。第一法(目视法)除另有规定外,按各品种项下规定的浓度要求,在室温条件下将用水稀释至一定浓度的供试品溶液与等量的浊度标准液分别置于配对的比浊用玻璃管(内径15-16 mm,平底,具塞,以无色、透明、中性硬质玻璃制成)中,在浊度标准液制备5 分钟后,在暗室内垂直置于伞棚灯下,照度为1000 lx,从水平方向观察、比较。除另有规定外外,供试品溶解后应立即检视。第一法无法准确判定两者的澄清度差异时,改用第二法进行测定,并以其测定结果进行判定。浊度标准存贮液的制备 称取于105℃干燥至恒重的硫酸肼1.00 g,置于100 ml量瓶中,加水适量使溶解,必要时可在40℃的水浴中温热溶解,并用水稀释至刻度,摇匀,放置4-6小时;取此溶液于等容量的10%乌洛托品溶液混合,摇匀,于25℃避光静置24小时,即得。该溶液置冷处避光保存,可在2个月内使用,用前摇匀。浊度标准原液的制备 取浊度标准贮备液15.0 ml,置1000 ml量瓶中,加水稀释至刻度,摇匀,取适量,置1 cm吸收池中,照紫外-可见分光光度法(通则0401),在550 nm的波长处测定,其吸光度在0.12-0.15范围内,该溶液应在48小时内使用,用前摇匀。浊度标准液制备 取浊度标准原液与水,按照下表配置,即得。浊度标准液应临用时制备,使用前充分摇匀。 第二法(浊度仪法)供试品的浊度可采用浊度仪测定。溶液中不同大小、不同特性的微粒物质包括有色物质均可使入射光产生散射,通过测定透射光或者散射光的强度,可以检查供试品的浊度。仪器测定模式通常有三种类型,透射光式、散射光式和透射光-散射光比较测量模式(比率浊度模式)。1.仪器的一般要求采用散射光式浊度仪时,光源峰值波长为860 nm;测量范围应包含0.01-100ntu。在0-10ntu范围内分辨率应为0.01ntu;在10-100ntu范围内分辨率应为0.1ntu.2.适用范围及检测原理本法采用散射光式浊度仪,适用于低、中浊度无色供试品溶液的浊度测定(浊度值为100ntu以下的供试品。)因为高浊度的供试品会造成多次散射现象,时散射光强度迅速下降,导致散射光强度不能正确反映供试品的浊度值。0.5-4号浊度标准液的浊度值范围约为0-40ntu。采用散射光式浊度仪测定时,入射光和测定的散射光呈90℃夹角,入射光强度和散射光强度关系式如下。i=k’t i0式中 i为散射光强度,单位为cd; i0 为入射光强度,单位为cd; k’为散射系数; t为供试品溶液的浊度值,单位为ntu(ntu是基于福尔马肼浊度标准液液测定的散射浊度单位,福尔马肼浊度标准液即为第一法中的浊度标准贮备液)。在入射光i0不变的情况下,散射光强度i与浊度值成正比。因此,可以将浊度测量转化为散射光强度的测量。3.系统的适用性试验仪器应定期(一般每月一次)对浊度标准液的线性和重复性进行考察,采用0.5号至4号浊度标准液进行浊度值测定,浊度标准液的测定解果(单位ntu)与浓度间应呈线性关系,线性方程的相关系数应不低于0.999;取0.5号至4号浊度标准液,重复测定5次,0.5号和1号浊度标准液测量浊度值的相对标准偏差应不大于5%,2-4号浊度标准液测量浊度值的相对标准偏差不大于2%。4.测定法按照仪器说明书要求并采用规定的浊度液进行仪器校正。溶液剂直接取样测定;原料药或者其它剂型按照个论项下的标准规定制备供试品溶液,临用时制备。分别取供试品溶液和相应浊度标准液进行测定,测定前应摇匀,并避免产生气泡,读取浊度值。供试品溶液浊度值不得大于相应浊度标准液的浊度值。 美国药典usp44 visual comparison 视觉比较the purpose of this test is to provide the details for the visual comparison of the color and/or turbidance of sample solutions of certain concentration to a standard solution or a series of standard solutions of known concentration. where a color or turbidity comparison is directed, follow the procedures and conditions outlined below for performing these tests.本试验的目的是提供特定浓度的样品溶液与已知浓度的标准溶液或一系列标准溶液的颜色和/或浊度的视觉比较细节。如果需要进行颜色或浊度比较,请遵循以下程序和条件进行这些测试 comparison vessels: color-comparison tubes matched as closely as possible in internal diameter, in depth of sample solution, and in all other respects should be used.对比容器:应使用内径、样品溶液深度和所有其他方面尽可能匹配的颜色对比管。 viewing conditions for turbidity comparison: tubes should be viewed horizontally against a dark background with the aid of a light source directed fromthe sides of the tubes.浊度比较的观察条件:应在黑暗背景下,借助从管子侧面发出的光源水平观察管子。 viewing conditions for color comparison: tubes should be viewed downward against a white background. most of the time, common room lighting is sufficient to perform the assessment. a light source directed from beneath the bottoms of the tubes may be used if needed and if the practice is consistent between the materials under comparison.颜色比较的观察条件:管子应在白色背景下向下观察。大多数情况下,公共空间照明足以进行评估。如果需要,并且对比材料之间的实践一致,可以使用从管底部下方引导的光源 nephelometry and turbidimetry 散射光浊度法和透射光比浊法1. introduction 介绍nephelometry and turbidimetry are analytical techniques that are based on the principles of light-scattering phenomena. light scattering is the physical phenomenon in which a beam of light changes its direction of propagation (known as deflection) as a result of interaction with sufficiently small matter particles. it has been established from the maxwell electromagnetic theory that a prerequisite for scattering to occur is that the refractive indexes of the suspended particles must be different from those of the suspending liquid. the larger the difference, the more intense the scattering becomes. there are two types of light scattering: 1) elastic scattering, in which the wavelength of the scattered light and incident light are the same and 2) inelastic light scattering, in which the wavelength of the scattered light and incident light are different. only the first type of light scattering (elastic) is relevant to nephelometry and turbidimetry.散射光浊度法和透射光比浊法是基于光散射现象原理的分析技术。光散射是一种物理现象,其中光束由于与足够小的物质粒子相互作用而改变其传播方向(称为偏转)。根据麦克斯韦电磁理论,散射发生的先决条件是悬浮颗粒的折射率必须不同于悬浮液体的折射率。差异越大,散射越强烈。光散射有两种类型:1)弹性散射,其中散射光和入射光的波长相同;2)非弹性光散射,其中散射光和入射光的波长不同。只有前一种光散射(弹性)与散射光浊度法和透射光比浊法有关。 in turbidimetry, the intensity of the transmitted light is measured and the attenuation of the intensity of incident light as a result of scattering is measured at the direction of incident light (i.e., 0°) and compared to the intensity of incident light (blank measurement). the measured property is an indirect measurement of the scattering effect of the suspended particles and is referred to as turbidance. any absorbance of light by the suspended sample will result in additional attenuation of light intensity (see ultraviolet-visible spectroscopy and ultraviolet-visible spectroscopy—theory and practice ). hence, it is important to ensure that the material being measured does not absorb light at the measurement wavelength. indeed the equations governing absorption and turbidimetry are the same (albeit with different values for the attenuation constants). in nephelometric techniques, the intensity of the scattered light at a 90° angle from the propagation direction of the incident light is measured. therefore, a nephelometric measurement is a direct measurement of the scattering effect of suspended matter.在透射光比浊法中,测量透射光的强度,并在入射光方向(即0°)测量散射导致的入射光强度的衰减,并与入射光强度进行比较(空白测量)。被测特性是悬浮颗粒散射效应的间接测量,称为浊度。悬浮样品对光的任何吸收都会导致光强度的额外衰减(参见 ultraviolet-visible spectroscopy和 ultraviolet-visible spectroscopy—theory and practice)。因此,确保被测材料不会吸收测量波长处的光非常重要。实际上,控制吸收和浊度测定的方程式是相同的(尽管衰减常数的值不同)。在散射光浊度法中,测量与入射光传播方向成90°角的散射光强度。因此,散射光浊度法浊度测量是对悬浮物散射效应的直接测量。 2. terms and definitions 术语和定义terms commonly used in describing turbidimetric and nephelometric techniques are:• turbidance (symbol, s): a measure of the decrease of the transmitted incident light beam intensity as a result of the light-scattering effect of suspended particles. the amount of suspendedmatter may be measured by observation of either the transmitted light (turbidimetry) or the scattered light (nephelometry).log i0/it = kbc = ti0 = intensity of incident lightit = intensity of transmitted lightk = molar turbidity coefficientb = cell path lengthc = concentrationt = turbidance• turbidity (symbol, τ): in turbidimetric measurements, the turbidity is the measure of the decrease in incident beam intensity/unit length of a given suspension. the international organization for standardization defines turbidity as “the reduction of transparency of a liquid caused by the presence of undissolved matter”.• turbidity measurement units: the turbidity units are stated using a descriptor which indicates the method of measurement.• nephelometric turbidity units (ntus): when the turbidity is measured using a nephelometer, which measures the scattered light at a 90° angle from the direction of propagation of incident light, the units of turbidity are called nephelometric turbidity units (ntus). the magnitude of ntu is defined based on the turbidity generated by primary formazin standard (a suspension made by mixing solutions of hydrazine sulfate and hexamethylenetetramine in water). safer polymer-bead suspensions are now commercially available and are recognized as an acceptable alternative. however, all those standards are traced to formazin. the primary formazin standard solution has been assigned a turbidity of 4000 ntus.other recognized units for turbidity include the formazin turbidity unit (ftu) and the formazin nephelometric unit (fnu). these units are equivalent to ntu for the range from 0–40 ntus.描述浊度法和浊度法的常用术语包括:• 浊度(符号s):由于悬浮颗粒的光散射效应,透射入射光束强度降低的一种度量。悬浮物的量可以通过观察透射光(比浊法)或散射光(浊度法)来测量。log i0/it = kbc = ti0=入射光强度it=透射光强度k=摩尔浊度系数b=样品池路径长度c=浓度t=浊度• 浊度(符号,τ):在透射光浊度测量中,浊度是给定悬浮液的入射光束强度/单位长度减少的量度。国际标准化组织将浊度定义为“由于存在未溶解物质而导致液体透明度降低”。• 浊度测量单位:浑浊度单位用一个描述符表示,该描述符指示测量方法。• 散射光浊度计浊度单位(ntu):当使用散射光浊度法测量浊度时,浊度计以与入射光传播方向成90°角的角度测量散射光,浊度单位称为散射光浊度法浊度单位(ntu)。ntu的大小是根据初级福尔马肼标准品(一种将硫酸肼和六亚甲基四胺溶液混合在水中制成的悬浮液)产生的浊度定义的。更安全的聚合物微珠悬浮液现已上市,并被公认为可接受的替代品。然而,所有这些标准都可以追溯到福尔马肼。初级福尔马肼标准溶液的浊度为4000 ntu。其他公认的浊度单位包括福尔马肼比浊法单位(ftu)和福尔马肼浊度法单位(fnu)。这些单位相当于0-40 ntu范围内的ntu。3. applications 应用turbidimetric and nephelometric techniques have applications that include 1) concentration determination of solutions and/or suspensions (determination of several cations and anions by precipitating and suspending the resulting precipitate at well-controlled reaction parameters) 2) measurement of the degree of turbidity of turbid solutions or suspensions 3) determination of weight-average molecular weights and dimensions of polydisperse systems in the molecular weight range from 1000 to several hundred million 4) measurement of immunoassays’ reaction kinetics or kinetics of immunoprecipitations (rate nephelometry) 5) monitoring of cell and bacteria growth and 6) particle size distribution determination of suspended material, particle counting, etc.透射光比浊法和散射光浊度法技术的sfer 50 ml of primary formazin standard to a 200-ml volumetric flask, and dilute with particle-free water to volume and mix. the resulting suspension has a turbidity of 1000 ntus.• formazin reference suspensions: prepare by mixing in a 100-ml volumetric flask, portions of the respective formazin stock standard suspension and particle-free water according to table 1.[注:以下所有的程序必须在20±2°的条件下进行(参见)]• 硫酸肼溶液:将1.000 g acs级硫酸肼(n2h4h2so4)溶解在100 ml 的a类容量瓶中中,并用无颗粒水稀释至刻度。让该溶液静置4-6
  • 标准溶液与溶液的区别?
    什么是溶液,什么是标准溶液?事实上有很多人经常将两者混淆,常规来说,溶液指的是多种或最少两种物质组成的混合物,而标准溶液则是具有准确已知浓度的试剂溶液,但标准溶液是属溶液,虽然两者有着明显的区别。下面小编来给大家详细介绍一下标准溶液与溶液的区别。  标准溶液与溶液的区别:  溶液是由至少两种物质组成的均一、稳定的混合物,被分散的物质(溶质)以分子或更小的质点分散于另一物质(溶剂)中。物质在常温时有固体、液体和气体三种状态。  溶液的均一性包含密度,组成,性质都一样,除此外,溶液还分为饱和溶液和不饱和溶液。  标准溶液是容量分析中常用的一种滴定溶液,靠它测得待测物的含量。靠它求得未知溶液的浓度。在其他的分析方法中用标准溶液绘制工作曲线或作计算标准。  有些标准溶液由于很不稳定,以至难以配制和使用,因此是不能利用的。  这样的标准溶液包括硫化氢(H2S)、二氧-化氯(ClO2)、溶解氧(DO)和臭氧(O3)。液-氯标准溶液只能配制成高浓度溶液,所以必须加入高纯水进行稀释,并且使用不会消耗液-氯的玻璃器皿。  远慕专注标准物质研发与产,供应标准物质,标准品,标准溶液,对照品,标准样品,滴定标液,单标,混标定制服务。
  • 美国撤销呋喃丹在食品的残留限量
    2009年10月30日,据美国环保署消息,美国环保署将继续执行2009年5月份实施的有关撤销杀虫剂呋喃丹残留限量的最终规定,因为有证据表明,摄入呋喃丹不安全,不符合当前的食品安全标准。   据了解,呋喃丹的短期健康影响包括头痛、出汗、恶心、腹泻、胸痛、视力模糊、焦虑和一般肌肉乏力。目前,美国环保署鼓励使用者选择更加健康的杀虫剂或其他更可取的环保有害生物控制方法。据悉,自从2009年5月份开始撤销呋喃丹的限量后,自2009年12月31起将不允许使用者将其应用于任何种植作物,在此日期后使用该杀虫剂将被认为产品受到污染,并将受到美国食品药物管理局的执法监督。
  • J.T.Baker原子吸收标准溶液清凉促销中
    火热一夏,J.T.Baker原子吸收标液清凉促销中(2010.8.1-2010.8.31) 可靠精确的标准产品的有效性对仪器分析的成功非常关键!在各种元素分析应用领域,需要使用分析标准产品为定量分析做出标准曲线以及对仪器进行标定。标准产品必须稳定并且所要测试元素的浓度必须非常准确。 J.T.Baker原子吸收标准产品用99.99%光谱的纯金属和盐溶于特别挑选的基质中配制而成。我们的标准产品包括35种元素,浓度为1,000 &mu g/mL,采用150mL瓶装。 所有的标准产品均经标准产品认证,可追溯至美国标准技术研究院(NIST)标准参考物质(SRM)编号,该编号印在产品标签上。 为了更好的回馈广大客户的支持,为中国大陆检测事业尽一份绵薄之力,在2010年这个夏天中,J.T.Baker中国特推出原子吸收标液(AAS标液)冰点促销活动,活动期间凡购买J.T.Baker原吸标准溶液均可享受七折优惠,产品列表如下: J.T.Baker原子吸收标液 B6440-04 铝AAS标准溶液1,000 UG/ML 150ML B6441-04 镝AAS标准溶液1,000 UG/ML 150ML B6442-04 砷AAS标准溶液1,000 UG/ML 150ML B6443-04 钡AAS标准溶液1,000 UG/ML 150ML B6444-04 铍AAS标准溶液1,000 UG/ML 150ML B6445-04 铋AAS标准溶液1,000 UG/ML 150ML B6446-04 硼AAS标准溶液1,000 UG/ML 150ML B6447-04 镉AAS标准溶液1,000 UG/ML 150ML B6448-04 钙AAS标准溶液1,000 UG/ML 150ML B6449-04 铬AAS标准溶液1,000 UG/ML 150ML B6450-04 钴AAS标准溶液1,000 UG/ML 150ML B6451-04 铜AAS标准溶液1,000 UG/ML 150ML B6452-04 金AAS标准溶液1,000 UG/ML 150ML B6453-04 铁AAS标准溶液1,000 UG/ML 150ML B6454-04 镧AAS标准溶液1,000 UG/ML 150ML B6455-04 铅AAS标准溶液1,000 UG/ML 150ML B6456-04 锂AAS标准溶液1,000 UG/ML 150ML B6457-04 镁AAS标准溶液1,000 UG/ML 150ML B6458-04 锰AAS标准溶液1,000 UG/ML 150ML B6459-04 汞AAS标准溶液1,000 UG/ML 150ML B6460-04 钼AAS标准溶液1,000 UG/ML 150ML B6461-04 镍AAS标准溶液1,000 UG/ML 150ML B6462-04 钯AAS标准溶液1,000 UG/ML 150ML B6463-04 铂AAS标准溶液1,000 UG/ML 150ML B6464-04 钾AAS标准溶液1,000 UG/ML 150ML B6465-04 硒AAS标准溶液1,000 UG/ML 150ML B6466-04 硅AAS标准溶液1,000 UG/ML 150ML B6467-04 银AAS标准溶液1,000 UG/ML 150ML B6468-04 钠AAS标准溶液1,000 UG/ML 150ML B6469-04 锶AAS标准溶液1,000 UG/ML 150ML B6470-04 钍AAS标准溶液1,000 UG/ML 150ML B6471-04 锡AAS标准溶液1,000 UG/ML 150ML B6472-04 钛AAS标准溶液1,000 UG/ML 150ML B6473-04 钒AAS标准溶液1,000 UG/ML 150ML B6474-04 锌AAS标准溶液1,000 UG/ML 150ML J.T.Baker充分理解您的需求并拥有一系列用于原子吸收法和ICP法测试应用的J.T.Baker 标准产品。为方便您的测试,我们提供单元素AAS标准产品以及单元素和多元素等离子标准产品,包括许多专门用于EPA标准和EPA合同实验室项目(CLP)的标准产品。 联系方式 杰帝贝柯化工产品贸易(上海)有限公司 地址:上海市浦东新区浦东南路999号新梅联合广场14层A座[200120] 电话:021-58783226 传真:021-58777253 E-Mail:sales.jtbs@covidien.com 关于J.T.Baker   杰帝贝柯化工产品贸易(上海)有限公司(JTBs)于2009年正式成立,是美国MallinckrodtBaker Inc的全资子公司。MallinckrodtBaker Inc拥有的J.T.Baker和Mallinckrodt 两大品牌有130多年的历史,其化学品领域的高品质产品,最优化的应用方案和功能性检测可以满足客户的高端应用需求,并确保高精度和高重现性的结果。
  • 中国兽医药品监察所就《动物性食品中二苯乙烯类药物残留量的测定 液相色谱-串联质谱法》等7项食品安全国家标准公开征求意见
    各相关单位:  根据《中华人民共和国食品安全法》和《中华人民共和国农产品质量安全法》有关要求,我办组织起草了《动物性食品中二苯乙烯类药物残留量的测定 液相色谱-串联质谱法》等7项食品安全国家标准。现公开征求意见,如有修改意见,请于2022年7月10日前反馈至全国兽药残留专家委员会办公室。  联系人:张玉洁  联系电话:010-62103930  E-mail:syclyny@163.com  地址:北京中关村南大街8号科技楼206  邮编:1000811. 动物性食品中二苯乙烯类药物残留量的测定 液相色谱-串联质谱法   本标准规定了猪、牛、羊、鸡组织(肌肉、肝脏、肾脏和脂肪)、鸡蛋、牛奶中己烯雌酚、己烷雌酚和己二烯雌酚残留量检测的制样和液相色谱-串联质谱测定方法。方法原理为:试样中残留的药物经酶解后用乙腈提取(脂肪样品先经乙腈提取,吹干复溶后再酶解),加入正己烷和乙酸乙酯后进行液-液-液三相体系净化,取中间层氮吹复溶后通过碳酸钠溶液液液萃取和硅胶柱固相萃取进行净化,液相色谱-串联质谱仪测定,基质匹配内标法定量。   2.牛可食性组织中盐霉素残留量的测定 液相色谱-串联质谱法   本标准规定了牛可食性组织中盐霉素残留量检测的制样和液相色谱-串联质谱测定方法,适用于牛肌肉、肝脏、肾脏和脂肪组织中盐霉素残留量的测定。方法原理为:试样中的药物残留用乙腈提取,提取液过滤膜后用液相色谱-串联质谱仪测定,基质匹配外标法定量。   3. 动物性食品中碘醚柳胺残留量的测定 高效液相色谱法   本标准规定了动物性食品中碘醚柳胺的制样和高效液相色谱测定方法。适用于牛、羊的肌肉、肝脏、肾脏和脂肪组织中碘醚柳胺残留量的测定。方法原理为:试样中残留的碘醚柳胺,经乙腈-丙酮溶液提取,混合型阴离子交换固相萃取柱净化,高效液相色谱-荧光法测定,外标法定量。   4. 禽蛋中β内酰胺类药物残留量的测定 液相色谱-串联质谱法   本标准规定了禽蛋中青霉素V、青霉素G、氨苄西林、氯唑西林、阿莫西林、头孢氨苄、头孢喹肟残留量检测的制样和液相色谱-串联质谱测定方法。方法原理为:试样中残留的青霉素 V、青霉素 G、氨苄西林、氯唑西林、阿莫西林、头孢氨苄、头孢喹肟,经 80%乙腈水溶液提取,固相萃取柱净化浓缩,液相色谱-串联质谱测定,基质匹配标准溶液内标法定量。   5. 禽蛋中头孢噻呋残留量的测定 液相色谱-串联质谱法   本标准规定了禽蛋中头孢噻呋代谢物去呋喃甲酰基头孢噻呋残留量检测的制样和液相色谱-串联质谱测定方法。方法原理为:试样中残留的头孢噻呋及代谢物,加入 0.4%二硫赤藓醇溶液混匀,用 14%碘乙酰胺溶液衍生化,生成稳定的乙酰胺衍生物,水饱和正己烷除脂,固相萃取柱净化浓缩,液相色谱-串联质谱测定,内标法定量。   6. 禽蛋中卡巴氧和喹乙醇的代谢物残留量的测定 液相色谱-串联质谱法   本标准规定了禽蛋中卡巴氧代谢物喹噁啉-2-羧酸(QCA)和喹乙醇代谢物 3-甲基喹噁啉-2-羧酸(MQCA)残留量检测的制样和液相色谱-串联质谱测定方法。方法原理为:试料中QCA和MQCA残留经偏磷酸溶液水解提取,叔丁基甲醚萃取后,用磷酸盐缓冲液反萃取,混合型强阴离子交换柱净化,酸性甲醇洗脱,液相色谱-串联质谱法测定,内标法定量。   7. 水产品中邻苯二甲酸酯类物质的测定 液相色谱-串联质谱法   本标准规定了水产品中邻苯二甲酸二甲酯、邻苯二甲酸二乙酯、邻苯二甲酸二烯丙酯等21种邻苯二甲酸酯(PAEs)含量检测的制样和液相色谱-串联质谱测定方法。方法原理为:水产品中的邻苯二甲酸酯经乙腈提取,分散固相萃取净化,反相液相色谱柱分离,以甲醇和0.1%甲酸水溶液为流动相进行洗脱,应用高效液相色谱-串联质谱法测定和确证,基质匹配外标法定量。
  • 日立UH5700 | 色素溶液的色度分析
    1. 前言色度分析传统上使用目视比色法,通过人眼比对标准物的颜色来确定,具有较大的主观性。紫外可见近红外分光光度计UH5700中的操作软件UV Solutions Plus标配峰值检测、半峰宽计算和四则运算功能。同时,通过UV Solutions Plus的选配程序包,可以直接进行色度计算。 此次实验,使用UH5700测定5个色素样品的吸收光谱,并依据日本标准JIS Z8781-3等计算色度。2. 应用数据紫外可见近红外分光光度计UH5700的选配程序包可以实现色度计算,包括三刺激值,XYZ表色系统、L*a*b*表色系统、Hunter Lab表色系统、L*u*v表色系统、黄变指数、色差等。图1 紫外可见近红外分光光度计UH5700以甲苯溶液为参比溶液,使用UH5700测定色素溶液的吸收光谱如下图所示。图2 色素溶液的吸收光谱利用 UV Solutions Plus 选配程序包,按照日本产业标准(JIS Z 8781-3:2016)中规定的CIE三刺激值,计算360~830 nm波长的色度。xy色度图如下所示。图3 五种色素溶液在XYZ表色系统中的色度图图中的曲线为光谱曲线,曲线上的每一点为单色波长,曲线中所包围的部分,其中任何一点即对应的颜色。如五种色素溶液在色度图中的位置如图所示。4号色素溶液和5号色素溶液的色调接近。 另外,通过在选配程序包中选择色度计算的波长范围和计算方法,能够同时计算多个样品的色度,并以表格一览显示。表1 色素溶液的色度计算结果3. 结论使用日立台式紫外可见近红外分光光度计UH5700可以根据不同的标准进行各种颜色计算,确保结果的准确性,助力科研人员定量分析物质的色度值和色差。除色度分析之外,UH5700的丰富附件还可满足液体样品的连续和微量分析,以及固体样品的透过率和反射率测定。
  • 河南一学校实验室液溴泄漏
    5月10日上午10时50分,河南洛阳市栾川消防大队接到报警:第四高级中学实验室里液溴泄漏,由于学校没有防护装备,人员无法靠近,请消防官兵火速赶往处置。   据学校的一位老师介绍,自己在实验室里拎装液溴瓶子的塑料袋时,瓶子从袋子底部滑落打破,液溴洒落后开始挥发。   此时,淡红色的烟雾还在向楼道中弥漫,刺鼻的气味呛得人不敢靠前。身着防护装备的官兵迅速进入实验室,再次用碱对液溴进行了稀释、调和,并把地上的残留物装在了一个玻璃坛子里,拿出来后埋在了实验室后面的荒地里。随后,官兵用纯碱溶液将残留的液体冲净,用喷雾器喷洒碱溶液对实验室和楼道进行了消毒,并打开楼道窗户通风、换气,确保万无一失后才离开了现场。
  • 农残、兽残标准品溶液自由组合,开启神速实验模式
    食品安全已经上升到了关系国际民生和国家安全战略的高度,为确保国民“舌尖上的安全”,2014年8月1日,由农业部与国家卫生计生委联合发布的新版《食品中农药最大残留限量》(GB2763-2014) 标准正式实施,不仅要求部分农药的残留量降低,而且增加了新农药的残留标准,被称为“最严的农药残留国家标准”。2015 版药典通则2341中规定了76 种农药的气相色谱串联质谱法和155 种农药的液相色谱串联质谱法及检出限。随着多项农残限量标准出台,对于食品及药品相关产业影响巨大,对各检测机构的硬件设备及检测技术提出了更高的要求,对标准品的需求也更大。在农药残留、兽药残留检测的日常工作中,科研工作者经常需要购买很多的标准品,花费很多的时间配制标准溶液和混标溶液,既费时又费力,而且容易造成浪费。 近期,Sciex连续发布多种农药兽药分析方法。《蔬菜和水果中农残分析的整体解决方案》,对农业部规定的70多种例行监测的农药中适合液质联用检测的51种农药给出了快速高效的定量分析方法。《动物源食品中多兽药残留的181种高通量筛查和定量方法》,使用QTRAP?4500液相色谱质谱联用系统建立了一种多兽残高通量的筛查和定量方法,包含18大类181个常见兽药。该方法在鸡肉、牛肉、猪肉等基质中通过验证,可用于肉中多兽残的筛查和定量分析,整个样品分析过程简单、快速、通用、灵敏。《GB 2763-2014 标准中307种农药的MRM离子对数据库》,针对 GB 2763-2014标准中307种可以液质离子化的农药建立了MRM离子对数据库,包括了 MRM 质谱方法所有参数信息,可直接用于建立农残检测的 LC-MS/MS 分析方法。 作为Sciex密切的合作伙伴,阿尔塔科技在Sciex农药兽药残留分析方法研发过程中积极配合,提供以上检测方法的相关标准品,并在新方法的研究中通力合作,不仅能够提供新版药典中容易质子化的GC/MS-MS方法中的76种农药、LC/MS-MS方法中的155种农药,还可以提供《GB 2763-2014》 标准中其他种类的标准品,根据客户需要研制各种农药兽药的标准溶液和混标溶液,有效搭配,自由组合,从几个品种到几十个、上百个品种,即开即用,省钱省力省时间,助您提高实验效率! 《动物源食品中多兽药残留的181种高通量筛查和定量方法》 包括以下各种标准品、标准溶液及混标溶液的组合方法包1ST9232-Kit 181种兽药混标 1ST2210醋酸甲羟孕酮,1ST2218地塞米松,1ST8020劳拉西泮,1ST5719氟罗沙星,1ST2221甲睾酮,1ST2241醋酸泼尼松龙,1ST8029三唑仑,1ST7801红霉素,1ST2286丙酸睾丸素,1ST2219醋酸地塞米松,1ST8031奥沙西泮,1ST7802A林可霉素盐酸盐,1ST2208醋酸氯地孕酮,1ST2235倍他米松戊酸酯,1ST8021硝西泮,1ST7803A盐酸克林霉素,1ST2292去氢睾酮,1ST2253,醋酸倍他米松,1ST5556羟基甲硝唑,1ST7712罗红霉素,1ST2275群勃龙,1ST8531莫美他松,1ST5554甲硝唑,1ST7809交沙霉素,1ST8505苯丙酸诺龙,1ST2244氟轻松醋酸酯,1ST5525二甲硝咪唑 ,1ST7806泰乐菌素,1ST7191格列本脲,1ST2242阿氯米松双丙酸酯,1ST5568罗硝唑,1ST7009吉他霉素,1ST7192格列美脲,1ST7200替诺昔康,1ST5519氯甲硝咪唑,1ST7805替米考星,1ST7193格列吡嗪,1ST8002氟芬那酸,1ST5513苯硝咪唑,1ST7013头孢氨苄,1ST7195瑞格列奈,1ST8009茚酮苯丙酸,1ST5542异丙硝唑,1ST12001头孢匹啉,1ST7197甲苯磺丁脲,1ST8004双水杨酸酯,1ST5501阿苯达唑,1ST10007头孢克洛,1ST2227泼尼松,1ST7152卡洛芬,1ST5505阿苯哒唑亚砜,1ST12002头孢克肟,1ST2228可的松,1ST7153酮基布洛芬,1ST5536氟苯咪唑,1ST12003头孢拉定,1ST2226氢化可的松,1ST7154托灭酸,1ST5531芬苯达唑,1ST10009头孢匹罗,1ST2229甲基泼尼松龙,1ST7155,美洛昔康,1ST5561奥芬达唑,1ST12004,头孢他美酯,1ST2246氟米龙,1ST7156氟尼辛,1ST5546甲苯咪唑,1ST7014头孢唑啉,1ST2230倍他米松,1ST7159甲芬那酸,1ST2522噻苯哒唑,1ST120053-去乙酰基头孢噻肟,1ST2224曲安西龙,1ST7161双氯芬酸,1ST5579替硝唑,1ST12006头孢孟多锂,1ST2262醋酸泼尼松,1ST7162吡罗昔康,1ST5591奥硝唑,1ST12012头孢米诺钠盐,1ST2238醋酸可的松,1ST7165萘丁美酮,1ST1307A莱克多巴胺盐酸盐,1ST12007头孢哌酮钠,1ST2240醋酸氢化可的松,1ST7166舒林酸,1ST1302沙丁胺醇,1ST12011头孢羟氨苄,1ST2232倍氯米松1ST7167托麦汀,1ST1304A特布他林硫酸盐,1ST7003头孢噻呋,1ST2231氟米松,1ST7168吲哚美辛,1ST1309西马特罗,1ST10011头孢氨噻,1ST2257甲基泼尼松龙醋酸酯,1ST4017磺胺嘧啶,1ST1301A,盐酸克伦特罗,1ST10012头孢他啶,1ST2247醋酸氟米龙,1ST4007磺胺噻唑,1ST1303妥布特罗盐酸盐,1ST12008头孢洛宁,1ST2256醋酸氟氢可的松,1ST4003磺胺吡啶,ST1324A喷布特罗盐酸盐,1ST12009头孢喹肟,1ST2236布地奈德,1ST4002磺胺甲基嘧啶,1ST8033A盐酸普萘洛尔,1ST4102四环素,1ST2249氢化可的松丁酸酯,1ST4014磺胺二甲基嘧啶,1ST1313氯丙那林,1ST4111A盐酸土霉素,1ST2233曲安奈德,1ST4040磺胺间甲氧嘧啶,1ST4107恩诺沙星,1ST4110A盐酸金霉素,1ST2234氟氢缩松,1ST4008磺胺甲噻二唑,1ST5738诺氟沙星,1ST4122X多西环素单盐酸半乙醇半水合物,1ST2254地夫可特,1ST4036磺胺对甲氧嘧啶,1ST5756培氟沙星,1ST7137奥拉多司,1ST2250氢化可的松戊酸酯,1ST4034磺胺氯哒嗪,1ST5703环丙沙星,1ST7104氯羟吡啶,1ST2248哈西奈德,1ST4004磺胺甲氧哒嗪,1ST5740氧氟沙星,1ST10021金刚烷胺,1ST2237氯倍他索丙酸酯,1ST4006磺胺邻二甲氧嘧啶,1ST5757沙拉沙星,1ST7001氯霉素,1ST2263醋酸曲安奈德,1ST4042磺胺间二甲氧嘧啶,1ST5714依诺沙星,1ST7002甲砜霉素,1ST2260倍他松丁酸酯,1ST4005磺胺甲基异噁唑,1ST5759洛美沙星,1ST7005氟苯尼考,1ST2251泼尼卡酯,1ST4010磺胺二甲异噁唑,1ST5735萘啶酸,1ST2215己烯雌酚,1ST2255二氟拉松双醋酸酯,1ST4012苯甲酰磺胺,1ST5745恶喹酸,1ST2217双烯雌酚,1ST2243安西奈德,1ST4028磺胺喹恶啉,1ST5761氟甲喹,1ST7201A玉米赤霉醇,1ST2259莫米他松糠酸酯,1ST4001磺胺醋纤,1ST4100达氟沙星,1ST7201B β-玉米赤霉醇,1ST2261倍氯米松双丙酸酯,1ST4009甲氧苄氨嘧啶,1ST5758双氟沙星,1ST7202α-玉米赤霉烯醇,1ST2239氟替卡松丙酸酯,1ST4013磺胺苯吡唑,1ST5743奥比沙星,1ST7202B β-玉米赤霉烯醇,1ST2252醋酸曲安西龙双,1ST8015咪哒唑仑,1ST5753司帕沙星,1ST7203玉米赤霉酮,1ST2225泼尼松龙,1ST8016阿普唑仑,1ST7204玉米赤霉烯酮,1ST8019氯硝西泮,1ST7102地西泮 《蔬菜水果中农业部例行监测农残的LC-MS/MS分析方法》中包括以下51种纯品、标准溶液及混标溶液的组合方法包1ST27019-10M,51种农药混标,10ppm 1ST21058多菌灵,1ST20348氟啶脲,1ST20140甲基对硫磷,1ST20297啶虫脒,1ST25000阿维菌素,1ST20111杀螟硫磷,1ST20298吡虫啉,1ST20167氧乐果,1ST20065倍硫磷,1ST20001毒死蜱,1ST20345除虫脲,1ST20173水胺硫磷,1ST20350噻虫嗪,1ST20127甲基异柳磷,1ST20434对硫磷,1ST21145烯酰吗啉,1ST20097敌敌畏,1ST21202三唑酮,1ST21189苯醚甲环唑,1ST20093甲胺磷,1ST20094二嗪磷,1ST21226腐霉利,1ST20449灭多威,1ST20349灭幼脲,1ST20305氟虫腈,1ST20144乙酰甲胺磷,1ST20189亚胺硫磷,1ST20438三唑磷,1ST21161嘧霉胺,1ST20168马拉硫磷,1ST20155丙溴磷,1ST20277甲萘威,1ST20406哒螨灵,1ST22249二甲戊灵,1ST20273涕灭威亚砜,1ST20172伏杀硫磷,1ST20271克百威,1ST20375涕灭威,1ST21157嘧菌酯,1ST20170辛硫磷,1ST20098乐果,1ST20288甲氨基阿维菌素苯甲酸盐,1ST21164异菌脲,1ST202593-羟基克百威,1ST20222甲氰菊酯,1ST20182敌百虫,1ST20266涕灭威砜,1ST20210联苯菊酯,1ST21247咪鲜胺,1ST20124甲拌磷,1ST20396虫螨腈 《GB2763-2014 标准中307种农药的MRM离子对数据库》中使用的纯品、标准溶液及组合混合标准溶液方法包参见1ST27048,307种农药混标溶液。 《2015版中国药典通则2341中76种农药的气相色谱串联质谱法》中使用的纯品、标准溶液及组合混合标准溶液方法包参见1ST27046,76种农药混标溶液。 《2015版中国药典通则2341中155 种农药的液相色谱串联质谱法》中使用的纯品、标准溶液及组合混合标准溶液方法包参见1ST27045,155种农药混标溶液。
  • Labhands全自动溶液配制仪参加绿绵科技产品发布会
    北京绿绵科技有限公司(简称:绿绵科技)是一家专业的仪器公司,本着诚信服务,追求卓越的宗旨,发扬勤奋自强,团结协作,不断进步的企业精神,多年来取得了卓越的成绩。2016年上海兰博贸易有限公司(Labhands)有幸与绿绵科技牵手,并授权其为指定区域的独家代理。7月底绿绵科技在天津成功举办了2016新产品发布会,Labhands品牌的全自动溶液配制仪有幸成为其中的一员。绿绵科技总经理欧阳先生对其公司的新品逐一介绍,很多新技术引起了台下客户的浓厚兴趣。会议间隙,很多用户立刻围了过来,对Labhands的全自动溶液配制仪工作原理、工作流程、方法编辑等问题问个不停,工程师一一解答。 附绿绵科技成长历程简介:◆2001年绿绵科技成为全球最大科学仪器和试剂公司—Thermo Fisher公司的色谱质谱产品线(原Finnigan产品线)中国区总代理◆2005年,绿绵科技引进德国Knauer公司40余年精密制造的HPLC系统硬件,开发自主知识产权的全中文色谱工作站,成为可靠性和易用性完美结合的典范。◆2007年,绿绵科技推广并代理美国Pittcon获奖产品MassWorks精确质量数测定及分子式识别系统。◆2009年,绿绵科技推出全新德国ECO GPC凝胶净化系统,为广大色谱、质谱工作者提供更优化的样品前处理解决方案。◆2009年,绿绵科技联合上海磐和科学仪器股份有限公司开发北方市场,推广各种样品前处理(GPC-SPE)、全自动热解析和苏玛罐等产品。◆2010年,绿绵科技推出全新德国ECO SPE全自动在线固相萃取-液相联用系统,为环境监测、生物医药、食品饮料等行业提供快速分析解决方案。◆2010年,绿绵科技联合华质泰科生物技术(北京)有限公司共同推出美国Pittcon金奖、R&D100金奖产品——实时直接分析质谱离子源DART。◆2010年,绿绵科技将软件界新一代服务模式SaaS和云计算平台引入分析测试行业,推出随需而变的LabOS实验室运营管理系统。◆2011年,绿绵科技推出法国F-DGSi公司的氮气/氢气/空气发生器,为广大液质联用仪、气相色谱、MP-AES等客户提供高纯、稳定、安全的气源。◆2011年,绿绵科技推出爱迪生2011年最佳新产品奖获奖产品——picoSpin微型核磁共振波谱仪。◆2012年,绿绵科技成为Excellims公司的中国区代理商,代理高分辨电喷雾离子迁移谱仪(HPIMS)。◆2012年,绿绵科技成为通用电气(GE)大中国区医疗集团全国药监系统的生命科学全线产品的授权分销商。◆2012年底,绿绵科技成为安捷伦CAG中端产品区域授权代理商,主要代理7820气相色谱仪、1220液相色谱仪、7697A顶空进样器、等产品。◆2012年底,绿绵科技成为加拿大AES公司中国总代理,代理新一代全柱成像毛细管等电聚焦电泳仪。◆2013年,绿绵科技成为New Objective(中国)公司北方地区唯一的代理商,主要代理LC-MS技术的纳喷雾离子源和消耗品。◆2013年3月,绿绵科技申请并通过了国家ISO9001质量管理体系认证,这标志着绿绵科技的售后服务水平迈上了一个崭新的台阶,客户满意度明显提升。◆2013年,绿绵科技代理的氮气发生器成为安捷伦MP-AES、液质联用仪产品的气源供应商。◆2014年,绿绵科技成为Freeslate在中国北方代理商,代理旗舰产品Core Module 3(CM 3)系统。◆2014年,绿绵科技成为通用电气(GE)大中国区医疗集团河南省及北京医院系统生命科学全线产品的授权分销商。◆2014年底,绿绵科技推出电泳生物耗材,为客户提供29种pI标记物、10种两性电解液载体、多种规格的分离柱及电泳仪分析溶液。◆2015年4月,绿绵科技第二十届全国色谱会学术报告会及仪器展览会上提出利用全柱成像毛细管电泳仪进行蛋白收集制备的突破性技术,在分离全柱进行可视蛋白的收集。◆2015年6月,绿绵科技推出电泳生物耗材新增3种pI标记物,最多可为客户提供32种pI标记物。◆2015年12月,北京绿绵科技有限公司成为瑞典Medicago AB在中国的授权代理商。◆2016年2月,绿绵科技成为安捷伦CAG中端产品区域授权代理商,主要代理7820气相色谱仪、1220液相色谱仪、配置7820GC和扩散泵5977B气质联用仪。 ◆2016年3月,绿绵科技举办公司成立15周年活动,对中国区域销售的LUMTECH液相进行免费检查的维护服务,推出氮气发生器保修合同和优惠方案。◆2016年6月,绿绵科技成为加拿大PromoChrom Technologies Ltd.公司全自动固相萃取仪在中国的独家代理商,在中国开展相关的产品销售及售后服务工作。◆2016年6月,绿绵科技取得英国牛津仪器磁共振(OXFORD Instruments Magnetic Resonance,OIMR)的核磁共振波普仪Pulsar的中国区域经销商资格。◆2016年6月,绿绵科技与上海兰博贸易有限公司达成合作协议,在指定区域内经销全自动溶液配制仪、全自动气体进样器。------
  • ASTM就聚氯乙烯中的邻苯二甲酸酯管控发布新规
    美国材料与实验协会(The American Society for Testing and Materials ,ASTM)就聚氯乙烯塑料(PVC)中的低水平邻苯二甲酸酯的控制决定发布自愿性标准ASTM D7823-13。该标准提供了热脱附–气相色谱/质谱法(Thermal Desorption – Gas hromatography / Mass Chromatography,TD-GCMS)来识别并测定6种邻苯二甲酸酯(DBP、BBP、DEHP、DNOP、DINP 和 DIDP)的数量。   新的ASTM标准介绍TDGC/MS为一种分析方法。样本是通过将PVC原料溶解在四氢呋喃(tetrahydrofuran)中而制备。“低水平”定义为1000 毫克/千克,然而目前还没有检测或定量的限值参考。所有邻苯二甲酸酯的相对标准偏差应好于5%。   涉及到的六种邻苯二甲酸酯受到以下法规规管,分别为:   一. 2008消费者产品安全改进法案(The Consumer Products Safety Improvement Act of 2008 ,CPSIA)   二. 欧洲委员会法规(EC) 552/2009(REACH法规附件17)第51和52部分   三.日本卫生、劳动及福利部第336号指导法案(Japan’s Health, Labour and Welfare Ministry (HLWM) Guideline No. 336)(2010)   四.加拿大消费者安全法案(The Canada Consumer Product Safety Act)SOR/2010-298   应该注明的是,受规管的邻苯二甲酸酯并不只是这些。比如,加州在第65号提案中规管了这六种中的四种(DNOP 和 DINP并不在65号提案的列表中),但是提案中另外一种邻苯二甲酸酯DnHP并不在本新规范围内。同时,丹麦环境部将在2015年规管上述的前三种邻苯二甲酸酯(DBP、BBP、DEHP)以及DIBP。最新的REACH SVHC候选清单中还包括了DPP、nPIPP、DIPP、BMP、DIBP、BBP、和 DPP。   表1 本文中使用的简称对照 简称 全名 CAS号 DEHP 邻苯二甲酸二辛酯 117-81-7 BBP 邻苯二甲酸丁苄酯 85-68-7 DBP 邻苯二甲酸二丁酯 84-74-2DIBP 邻苯二甲酸二异丁酯 84-69-5 DNOP 邻苯二甲酸二正辛酯 117-84-0 DINP 邻苯二甲酸二异壬酯 28553-12-0和 68515-48-0 DIDP 邻苯二甲酸二异癸酯 26761-40-0 和 68515-49-1 DnHP 邻苯二甲酸二正己酯 84-75-3 BMP 邻苯二甲酸二(2-甲氧基乙基)酯 117-82-8 nPIPP 邻苯二甲酸正戊基异戊基酯 776297-69-9 DPP 邻苯二甲酸二戊酯 131-18-0 DIPP 邻苯二甲酸二异戊酯 605-50-5
  • 粘度测定仪用毛细管法测定PET(聚对苯二甲酸乙二醇酯)树脂稀溶液的特性黏度
    PET又名聚对苯二甲酸乙二醇酯(polyethylene glycol terephthalate)是由对苯二甲酸二甲酯与乙二醇酯交换或以对苯二甲酸与乙二醇酯化先合成对苯二甲酸双羟乙酯,然后再进行缩聚反应制得,为乳白色或浅黄色、高度结晶的聚合物,表面平滑有光泽,是生活中常见的一种树脂。PET分为纤维级聚酯切片和非纤维级聚酯切片。①纤维级聚酯用于制造涤纶短纤维和涤纶长丝,是供给涤纶纤维企业加工纤维及相关产品的原料。涤纶作为化纤中产量最大的品种。②非纤维级聚酯还有瓶类、薄膜等用途,广泛应用于包装业、电子电器、医疗卫生、建筑、汽车等领域,其中包装是聚酯最大的非纤应用市场,同时也是PET增长最快的领域。众所周知,聚酯生产过程中,产品粘度是影响产品质量的一项重要指标,特别是热灌级聚酯产品生产过程中,由于该品种粘度指标范围窄,一旦受原料、生产过程控制等因素影响,未及时判断出原因进行调整,基础切片粘度无论是下降还是升高,若未及时将该部分切片进行有效隔离,直接进入到后续系统,将对后续固相增粘造成极大影响,致使调整困难,导致产品质量降等。聚酯生产过程中影响聚酯产品质量的因素很多,从纺丝的角度出发,主要有色相、端羧基、二甘醇含量及黏度等,其中以黏度对可纺性的影响最为显著。目前,绝大多数聚合装置都与直接纺长丝或短纤维的装置街接,并且越来越多的纺丝装置采用高速纺和细旦的品种,这就对熔体的质量特别是熔体的特性黏度稳定提出了更高的要求。 乌氏毛细管法是PET(聚对苯二甲酸乙二醇酯)材料质量控制中常用的分析方法之一,由乌氏毛细管法测量得出的特性粘度也是PET(聚对苯二甲酸乙二醇酯)材料的核心指标之一。实验所需仪器:卓祥全自动粘度仪、多位溶样器、自动配液器、万分之一电子天平。实验所需试剂:苯酚、四氯乙烷、三氯甲烷、丙酮或无水乙醇。1、溶剂的配置选择:根据PET材料分类所选溶剂配比不同,纤维级聚酯切片可选择苯酚/1,1.2,2-四氯乙烷(质量比3:2)亦可选苯酚/1,1.2,2-四氯乙烷(质量比1:1),瓶级聚酯切片选择苯酚/1,1.2,2-四氯乙烷(质量比3:2); 2、溶剂粘度的测定:卓祥全自动粘度仪设置到实验目标温度值并且稳定后,加入苯酚/1,1.2,2-四氯乙烷,软件中启动测试任务待结束。3、粘度管的清洗:启动卓祥全自动粘度仪清洗、干燥程序,仪器自动将粘度管清洗干燥后待用。4、PET树脂稀溶液样品的制备:在万分之一天平上精准称量精确到0.0001g,通过ZPQ-50自动配液器将溶液浓度精准配制到0.005g/ml,再将样品瓶放置到MSB-15多位溶样器中(纤维级90~100℃,瓶级110℃~120℃),待半小时内溶解完毕后取出冷却到室温待用。5、样品粘度的测定:加入样品,启动软件中特定公式测试,待任务结束。6、粘度管的清洗:再次启动卓祥自动粘度仪清洗、干燥程序,仪器自动将粘度管清洗干燥后待用。苯酚/1.1.2.2—四氯乙烷(质量比50:50)作溶剂的试验,按公式(1)、(2)、(3)计算相对黏度(ηr)、增比黏度(ηsp)和特性黏度([η]):式中:ηr——相对黏度;t1——溶液流经时间,单位为秒(s);to——溶剂流经时间,单位为秒(s);ηsp——增比黏度;[η]——特性黏度;c——溶液浓度,单位为克每百毫升(g/100mL)苯酚/1.1.2.2一四氯乙烷(质量比60:40)作溶剂的试验,其结果按公式(4)计算:本文章为原创作品,无原作者授权同意,不得随便转载拷贝,侵权必究!
  • 贵州大学池永贵团队Nat Commun | 国仪量子EPR助力合成苯并呋喃衍生物研究
    近日,贵州大学池永贵研究团队证明了杂原子阴离子可以用作超电子供体来引发自由基反应,从而轻松合成 3-取代苯并呋喃。所得产物在有机合成和农药开发方面具有广阔的应用前景。  相关成果以“Facile access to benzofuran derivatives through radical reactions with heteroatom-centered super-electron-donors”为题,发表于著名学术期刊《自然-通讯》(Nature Communications)。研究中使用了国仪量子的X波段连续波电子顺磁共振波谱仪EPR200-Plus,证实了反应体系中自由基物种的生成。  苯并呋喃是广泛存在于人类临床药物中的100种主要环状结构之一。特别是,在许多已被证实具有生物活性的天然和非天然药物分子中, 3-取代苯并呋喃经常被发现为核心结构。为快速而选择性地获得具有多种功能的3-取代苯并呋喃衍生物,开发高效的合成新方法至关重要。单电子转移反应是构建功能化 3-取代苯并呋喃的最有效途径之一,而合适的电子供体对单电子转移过程的成功至关重要。然而迄今为止,还未有研究报道采用以杂原子为中心的阴离子作为单电子转移反应的直接超级电子供体。图片来源:摄图网  贵州大学池永贵研究团队在研究中利用杂原子阴离子作为 SED 来引发自由基反应,从而轻松合成了具有各种杂原子官能团的 3-取代苯并呋喃分子。具有不同取代模式的膦、硫醇和苯胺在这种分子间自由基偶联反应中表现良好,并且具有杂原子官能团的 3-官能化苯并呋喃产物具有中等至优异的产率。  Fig. 1 | Bioactivities, syntheses of 3-substituted benzofurans and SEDs for radical reactions. a Commercial drugs containing 3-substituted benzofuran structures. b Typical methods for access to 3-substituted benzofurans. c Representative organic small molecular SEDs. d Heteroatom anions as SEDs for 3-heteroalkylbenzofuran synthesis.  研究中使用EPR技术(国仪量子EPR200-Plus)证实了反应体系中自由基物种的生成。在25℃ DME中,1a、HPPh2和LDA的混合物的EPR光谱在g = 2.0023处出现了类似于苯基g因子的信号。  Fig. 4 | EPR spectrum of the reaction mixtures and control experiments. a EPR spectrum of the reaction mixtures. b Feasibilities of the heteroatomic anions as SEDs for the radical reactions. c Cross-radical coupling reactions with mercaptans. d The X-band EPR spectrum of 1:2:2 stoichiometric reaction of 1a (0.1 mmol), HPPh2 (0.2 mmol), and LDA (0.2 mmol) was measured at 298 K with DME (2 mL) as solvent at a microwave frequency of 9.418333054 GHz (g = 2.0023).成果摘要  Nature Communications:通过与杂原子中心的超级电子供体的自由基反应轻松获得苯并呋喃衍生物  开发合适的电子供体对于单电子转移(SET)过程至关重要。使用杂原子中心阴离子作为直接 SET 反应的超电子供体 (SED) 的研究很少。在这里,我们证明杂原子阴离子可以用作 SED 来引发自由基反应,从而轻松合成 3-取代苯并呋喃。具有不同取代模式的膦、硫醇和苯胺在这种分子间自由基偶联反应中表现良好,并且具有杂原子官能团的 3-官能化苯并呋喃产物具有中等至优异的产率。通过控制实验和计算方法阐明了反应机理。所提供的产品在有机合成和农药开发方面显示出有前景的应用。国仪量子电子顺磁共振波谱仪国仪量子目前已推出具有核心自主知识产权、商用化的X波段电子顺磁共振波谱仪全系列产品:X波段脉冲式电子顺磁共振波谱仪EPR100、X波段连续波电子顺磁共振波谱仪EPR200-Plus、台式电子顺磁共振波谱仪EPR200M;并向前沿高端技术的高频谱仪进军,研发出了W波段脉冲式电子顺磁共振波谱仪EPR-W900。在化学、环境、材料物理、生物医疗、食品、工业领域有着重要而广泛的应用。国仪量子电子顺磁共振波谱仪全系列产品
  • 如何使用反向移液技术更精准的移取蛋白溶液
    每支移液器的液程通常都用纯水和正向移液技术校准过。因此我们推荐使用正向移液技术移取水性溶液,如缓冲液,稀释酸或碱。当移取不同于水的液体时,由于具有不同的液体特性,其移液量可能偏离所选的量程。比如一些生物溶液的移液,可能会在移液器尖端或试管中产生气泡或泡沫,这将使移液量产生偏差。在这种情况下,我们推荐使用反向移液技术移取高粘度或者容易产生泡沫的液体。反向移液技术减少了喷溅,泡沫和气泡形成。这种方法尤其适用于移取小体积的液体。 下面先介绍一下正向移液和反向移液技术的操作。 1.将按钮压至第一停点。 2.将吸头浸入液面下1cm处,缓慢释放按钮使其滑回原位。将吸头从液体中移出,接触容器边缘除去多余的液体。 3.排液时,吸头紧贴容器壁先轻按按钮至第一停点,略作停顿后, 将按钮按至第二停点(这个操作会将吸头内的液体彻底排尽),将吸头从容器中沿容器壁移出。 4.松开按钮至准备位置。 1.将按钮压至第二停点。 2.将吸头浸入液面1cm处,缓慢释放按钮使其滑回原位。这将时液体充满吸头。将吸头从液体中取 出,接触容器边缘去掉多余液体。 3.放液到接收容器时平稳地轻按按钮至第一停点。保持在这个位置。一些液体会残留在吸头中不能被放出。 4.残留在吸头内的液体能够被吹回原溶剂中或者同吸头一起丢弃。 5.松开按钮到准备位置。 选择合适的移液器对于微量移液的精准性也很重要,Thermo Scientific F系列移液器的超强吹出设计则满足了微量移液对精准性的需求。低于50&mu l液程的Thermo F系列移液器均采用双活塞设计,与其它普通移液器相比,其空气吹出能力增大50%-60%,因此在小体积的液体吹出时会非常干净完全,大大提高了移液的精准性。 我们使用Thermo Scientific Finnpipette F2 1-10 &mu l移液器,配合Thermo Scientific Finntip Flex 10吸头,同时分别使用正向移液和反向移液,移取1%牛血清白蛋白(BSA,Sigma A7030)进行移液精准性测试。 图1 表明当使用反向移液技术时,移液量的变化比使用正向移液技术处于更狭窄的一个范围。 图2 表明使用两种移液方式的不精确度。不精确度是估量移液的重复性的。反向移液技术可以使不精确度相对于正向移液技术降低50%。 这是因为,BSA溶液含有易被疏水移液器吸头壁吸附的疏水成分。当使用正向移液技术时,每次移液后少量的液体易残留在吸头中。这种趋势会增加吹出液体体积之间的偏差,因为当重复移液时吸头中累积的残余液体可能增加下一次移液的移液量。而反向移液技术中有额外的液体被吸入吸头中,这些额外的液体作用似一个蓄水池它使连续移液的移液量均等。这个蓄水池也能阻止空气在吹出液体的最后从吸头口进入,这样可以降低液体起泡的可能性。这使反向移液技术在移取小液量液体时尤其有用。由此可见,选择Thermo Scientific F2移液器,同时配合反向移液技术,可较好的提高移取蛋白溶液的精确度和重复性。 这是个移液器的王国,每个人都能找到最适合自己的移液器。这是一个富于创新的品牌,传承40年移液器的深厚底蕴。&ldquo 先锋源于创新,全新精准体验&rdquo 是赛默飞世尔科技移液器的真实写照。Thermo Scientific Finnpipette的历史可追溯到1971年,凭借着以人为本的设计理念,坚持不断创新,缔造了许许多多世界&ldquo 第一&rdquo 的记录。我们推出了全球第一支连续可调微量移液器、第一支多道移液器、第一支可整支高压消毒的移液器、第一支彩色标记移液器。Finnpipette特别重视客户反馈,不断努力改善产品。我们始终追求提高性能、精准性和客户满意度。更多Thermo Scientific移液解决方案请查看:Thermo移液器。
  • 事关药物质量安全,不可忽视的残留溶剂检测
    近期,吉林省药监局公示一则行政处罚决定书,吉林某制药公司因使用不合格的聚酯/铝/聚乙烯药用复合膜,被罚数万元,并被要求停止使用该产品。原因是该制药公司使用的这种产品,经吉林省药检所检验、复验,"溶剂残留量(甲苯)"项不符合规定。那么,问题来了!药品中怎么会有残留溶剂呢,其会对药品质量产生什么样的影响呢?药品中的残留溶剂系指在原料药或辅料的生产中,以及在制剂制备过程中使用的,但在工艺过程中未能完全去除的有机溶剂。残留溶剂的存在一方面可能改变药物的性状,如改变某些药物的晶型、增大药物吸潮,这往往会影响药物的质量;另一方面近年来残留溶剂的毒性及致癌作用日益引起医药管理部门的重视。因此药物中残留溶剂应尽量除去,并对其进行限量控制。为满足更多医药行业客户需求,我们为您带来《化学药品中残留溶剂检测应用文集》,涵盖原料药、药用辅料、成品药以及药物包材,涉及的仪器主要有顶空、气相、气质等仪器,一起来看看吧。世界主要国家及组织关于化药溶剂残留的规定药品的残留溶剂分析是药物分析的热点,已经成为药品质量控制的重要组成部分,是相关企业及药品检验实验室的常规检测项目。关于化药中的溶剂残留世界主要国家及组织都有相关规定及标准,如美国药典(USP)通则,欧洲药典(EP)2.4.24,我国最新版药典(ChP2020)四部0861,以及ICH Q3C。主要国家和组织对药品残留溶剂监管的法规国家或组织规定药物溶剂残留的具体标准中国中国药典四部0861ICHICH Q3C美国(USP)通则欧洲(EP)2.4.24ICH于1996年11月6日颁布了残留溶剂测定指导原则征求意见稿,并对外公布,以便获取公众对指导原则的建议,该指导原则的编号为Q3C。ICH Q3C自1997年7月17日被ICH指导委员会采用正式实施以来又经历了多次修订,如2000年增加四氢呋喃PDE(每日允许暴露量)信息、2010年增加异丙苯的PDE信息、2020年增加2-甲基四氢呋喃、环戊基甲基醚和叔丁醇PDE信息。残留溶剂检测 岛津方案集锦药物从原料到成品需要经过很多环节,这些环节所涉及到的一些物料都需要监测残留溶剂。本文集收集的检测方案按照检测对象,分为原料药、药物辅料、成品药以及药物包材四个部分。原料药中残留溶剂的检测对于化药原料药,其通常是通过复杂的化学反应过程制造的,在制造过程中往往必须使用特定的有机溶剂,但是这些有机溶剂有些在工艺过程中并未能完全去除。药品中的残留溶剂如果不能控制在一个合理的水平会严重影响药品的质量,同时也会对人们健康造成安全威胁。HS-GC法测定化学药品中3种溶剂残留的标准色谱图(1.0 µ g,1、叔丁醇,2、2-甲基四氢呋喃,3、环戊基甲基醚)药用辅料中残留溶剂的检测药用辅料是指在制剂处方设计时,为解决制剂的成型性、有效性、稳定性、安全性加入处方中除主药以外的一切药用物料的统称。药物制剂处方设计过程实质是依据药物特性与剂型要求,筛选与应用药用辅料的过程。药用辅料是药物制剂的基础材料和重要组成部分,是保证药物制剂生产和发展的物质基础,在制剂剂型和生产中起着关键的作用。它不仅赋予药物一定剂型。而且与提高药物的疗效、降低不良反应有很大的关系,其质量可靠性和多样性是保证剂型和制剂先进性的基础。同药品一样,药用辅料在生产的过程中也可能使用一些有机溶剂,这些溶剂如果有残留最终就可能引入到成品药中,因此有必要对药用辅料中的残留溶剂进行监控。GC测定药用辅料聚山梨酯80中6种杂质的标准溶液色谱图(100 µ g/mL,1、环氧乙烷,2、二氧六环,3、氯乙醇,4、乙二醇,5、二甘醇,6、三甘醇)成品药中残留溶剂的检测成品药就是具体的按照一定形式制备的药物成品,通常是以制剂形式存在。在药物生产中,制剂工业已发展成为一个独立的领域。目前,制剂有很多类型,如片剂、糖衣片、肠溶片、薄膜包衣片、注射剂、胶囊剂、栓剂、气雾剂、药膜剂以及各种缓释制剂和控制释放制剂等。成品药的成分既包括原料药,也包括在制剂生产过程中添加的各种药用辅料。这些成分以及制剂的生产过程中也可能向成品药中引入残留溶剂。为保证药品质量,作为药品生产的最后一环,成品药也必须对残留溶剂进行监控。HS-GC-FID/MS分析系统检测药物中残留溶剂的一类溶剂标准色谱图(溶液按照USP一类溶剂标准溶液配制)HS-GC/MS测定药品中19种溶剂残留的标准溶液色谱图(5.0 µ g)19种溶剂残留药用包材中残留溶剂的检测药品的包装材料通常采用的是高分子材料和金属薄膜等,这些材料在生产的过程中容易残留一些溶剂,另外药品包材在印刷的过程中也会由油墨引入一些溶剂的残留。这些沸点较低的溶剂通常易挥发,有很大可能直接向药物迁移,对人体健康造成损害。因此,对药品包材中的残留溶剂进行检测对于药品质量的控制来说非常必要。HS-GC/MS测定多层共挤膜中苯乙烯单体残留药物从原料到成品需要经过很多环节,这些环节所涉及到的一些物料都需要监测残留溶剂。这些物料主要包括原料药、药用辅料、成品药、药用包材等四类,而主要的检测方法是顶空气相色谱法(HS-GC)或是顶空气相色谱质谱法(HS-GC/MS)。GCMS-QP2020_NX+ HS-20《化学药品中残留溶剂检测应用文集》目录一、原料药中残留溶剂的检测HS-GC法测定化学药品中3种溶剂残留HS-GC使用恒流模式检测原料药中残留溶剂二、药用辅料中残留溶剂的检测GC测定药用辅料聚山梨酯80中6种杂质含量三、成品药中残留溶剂的检测HS-GC测定药品中溶剂残留HS-GC/MS测定药品中环氧氯丙烷残留HS-GC/MS测定药品中溶剂残留 错误HS-GC测定药品中甲醇、异丙醇、甲苯残留HS-GC测定药品中微量环氧氯丙烷残留HS-GC分析药物中的残留溶剂HS-GC-FID/MS分析系统检测药物中的残留溶剂以H2为载气分析非水溶性药物中的残留溶剂以H2为载气分析水溶性药物中的残留溶剂以N2为载气分析非水溶性样药物样品中的残留溶剂以N2为载气分析水溶性样药物样品中的残留溶剂GC用于不适合顶空进样的第2类溶剂的分析(水溶性样品)四、药用包材中残留溶剂的检测HS-GC/MS测定多层共挤膜中苯乙烯单体残留HS-GC/MS检测药品包材中溶剂残留HS-GC测定口服液体药用PET瓶中乙醛残留量HS-GC测定固体药品泡罩包装中的氯乙烯单体残留量HS-GC测定药用复合膜中挥发性有机物药品的残留溶剂分析是药物分析的热点,已经成为药品质量控制的重要组成部分,是相关企业及药品检验实验室的常规检测项目。岛津公司始终密切关注药品质量安全,积极参与药物相关法规所涉及分析方法的的开发与研究,及时为客户提供完整、准确应对解决方案,希望可以为相关领域客户提供参考。*本文内容非商业广告,仅供专业人士参考。
  • 荧光/磷光体系溶液结构测定动静态激光光散射谱仪
    成果名称 荧光/磷光体系溶液结构测定动静态激光光散射谱仪 单位名称 中国科学院化学研究所 联系人 程贺 联系邮箱 chenghe@iccas.ac.cn 成果成熟度 □研发阶段 &radic 已有样机 □通过小试 □通过中试 □可以量产 合作方式 □技术转让 □技术入股 &radic 合作开发 □其他 成果简介:荧光/磷光体系溶液结构测定动静态激光光散射谱仪通过引入二向色镜,采取叠光的手段,将785nm、633nm、532nm和457nm的激光作为光源,根据样品不同的吸收谱带选择样品无吸收的激光,解决了商业化动静态激光光散射谱仪无法测量荧光/磷光体系溶液结构的难题。该谱仪可精确测定流体力学半径在1nm-100&mu m,均方旋转半径在20nm-300nm尺寸范围的纳米、胶体、团簇颗粒等的溶液结构。 应用前景: 本项目可以吸引国内院所同行,尤其是本身已有商业化动静态激光光散射谱仪的同行的注意,吸引他们向我方申请加工、或者直接购买,在市场上有一定的应用前景。近两年来,仅德国ALV公司在中国市场购买就销售了15台左右谱仪,按每台谱仪的改装费80万元计算,我们的潜在市场至少有1200万元。
  • 国标计划溶液聚合丁苯橡胶微观结构测定红外ATR法拟立项
    p   日前,国家标准委发布201项拟立项推荐性国家标准项目征求意见的通知,其中国家标准计划《溶液聚合丁苯橡胶(SSBR)微观结构的测定 第2部分:红外光谱ATR 法》由TC35(全国橡胶与橡胶制品标准化技术委员会)归口上报,TC35SC6(全国橡胶与橡胶制品标准化技术委员会合成橡胶分会)执行,主管部门为中国石油和化学工业联合会。主要起草单位 中国石油天然气股份有限公司石油化工研究院 、中国石油天然气股份有限公司独山子石化研究院 、国家合成橡胶质量监督检验中心 、怡维怡橡胶研究院有限公司 。项目周期24个月。 /p p   SSBR的微观结构含量直接影响着抗湿滑性,滚动阻力、冲击强度、软化温度和硫化特性等重要性能,因此SSBR微观结构含量的控制在SSBR工艺技术研究、新产品开发、产品质量控制等工作中具有重要意义。目前,测定SSBR微观结构含量的方法有核磁共振法与红外光谱法。 /p p   核磁共振法需要配备核磁共振仪,因该仪器价格昂贵,维护、运行成本很高,不是通用型仪器,运用不广泛,很少用于常规检测,多用于标准物质定值。 /p p   红外光谱法是测定SSBR微观结构含量的通用方法。测定SSBR微观结构的红外光谱法包括红外光谱溶液涂膜方法和红外光谱ATR方法。GB/T 28728—2012规定了采用核磁法和红外光谱溶液涂膜法,对SSBR中微观结构含量进行定量测定的分析方法。但红外光谱溶液涂膜法需要将样品溶解再涂膜,溶解过程需要5个小时以上。且涂膜法直接读取吸光度,没有采取通常的扣除基线法,因此,基线对测定结果的影响很大。而且溶解的完全性和膜片的光滑、平整性都会影响基线,从而对测定结果产生较大的影响,测定结果的重复性不是很好。同时,该方法需要将样品溶解,对环境和实验人员健康有一定的不良影响。 /p p   ATR(衰减全反射)技术通过样品表面反射的光信号获得样品表层有机成分的结构信息。该技术由于无需溶解样品,也不需要制备样品盐片及设置透射池,并无损样品表面,完成1次测定只需要1分钟,且不消耗任何原材料和备品备件,方便、环保、快速,因此被广泛用于物质成分的定性和定量分析。 /p p   目前国内尚没有测定SSBR微观结构含量的红外光谱ATR法的相关标准,为了与国际标准接轨,扩大国际交流,同时也为SSBR的科研、生产、外贸提供一个统一、方便快捷、环保的微观结构测定方法,因此制定该标准十分必要。 /p p   本标准规定了采用红外光谱衰减全反射(ATR)法,对溶液聚合丁苯橡胶(SSBR)中丁二烯单体的微观结构和苯乙烯单体的含量进行定量测定的分析方法。 适用于溶液聚合丁苯橡胶,不适用于乳液聚合丁苯橡胶。 /p p   主要技术内容如下: 1)获得ATR谱图的步骤。 2)丁二烯微观结构和苯乙烯含量的测定:每个微观结构组分相应吸光度的测定 微观结构的计算( 每一个吸收谱峰的基线校正、吸光度的比值、二阶项、苯乙烯和微观结构的质量百分含量通过回归方程得到、微观结构的质量百分含量) 3)精密度。 4) 微观结构回归方程的获得。 5)核磁法测定微观结构。 /p p br/ /p
Instrument.com.cn Copyright©1999- 2023 ,All Rights Reserved版权所有,未经书面授权,页面内容不得以任何形式进行复制