型号: | 9057 |
产地: | 加拿大 |
品牌: | Sciencetech |
评分: |
|
Sciencetech高分系列辨率单色仪光谱仪
特征
l 高度可定制的模块化设计
l 两个可配置的输入和输出端口
l 可配置的刀塔和光栅选项
l USB2.0通讯
l 一整套输入和输出附件
l 提供完全集成的软件和开发库
参数
Model # | 9040 | 9490 | 9150 |
Input Focal Length (mm) | 500 | 914 | 1500 |
Output Focal Length (mm) | 550 | 1000 | 1500 |
Wavelength Selection | Motorized | Motorized | Motorized |
Communication | USB 2.0 | USB 2.0 | USB 2.0 |
Readout Mechanics | Sine Drive | Sine Drive | Sine Drive |
Spectral Range* | Varies with Grating Selection | ||
Aperture | F/4.0 , F/5.2 F/6.9 | F/7.4, F/9.7, F/13.0 | F/12 |
Maximum Grating Size (mm x mm) | 110mm x 110mm | 110mm x 110mm | 110mm x 110mm |
Number of Gratings | Up to 3 | Up to 3 | Up to 3 |
Optical Resolution*, ** | 0.03 | 0.017 (0.009 for DP) | 0.013 (0.0063 for DP) |
Stray Light | 4 E-4 | 4 E-4 | 4 E-4 |
Double Pass Option | NO | YES | YES |
Dispersion* (nm/mm) | 1.53 (0.75 DA) | 0.83 (0.42 DP) | 0.5 (0.25 DP) |
Wavelength Accuracy* (+ nm) | 0.05 | 0.03 | 0.02 |
Wavelength Reproducibility* (+ nm) | 0.025 | 0.01 | 0.002 |
Flat Field Size (mm) | 30 x 12 | 27 x 12 | 27 x 12 |
Flat Field Angle (deg) | -0.735 | 0.3 | 0.3 |
Optical Axis Height (mm/in) | 139 | 200.5 | 200.5 |
Dimensions (mm) | 711 x 381 x 254 | 1120 x 560 x 360 | 1600 x 572 x 381 |
Dimensions (in) | 28 x 15 x 10 | 44 x 22 x 14 | 63 x 22.5 x 15 |
Weight (kg) | 35 | 115 | 150 |
Power Consumption | 24V/60W | 24V/60W | 24V/60W |
* Specifications given for 1200l/mm gratings with 25um wide input slit
** Resolution for F/6.9 and F/13 on 9040 and 9490 Models
*** Note that the addition of powered accessories will increase the power consumption
光学配置
单色仪中使用的反射镜和光栅的大小决定了它的F /#。 随着F /#的降低,单色仪将收集更多的光。 在同一个单色仪中可以使用不同尺寸的光栅和反射镜,但是系统的吞吐量将取决于单色仪中*小的光学元件。
F/# Options | |||
Model | F/# | Nominal Grating Size (mm x mm) | Available Turret Configurations |
9040 | F/6.9 | 64 x 64 | 1G, 3G |
9040F | F/5.2 | 84 x 84 | 1G, * |
9040EF | F/4.0 | 102 x 102 | 1G * |
9490 | F/13 | 64 x 64 | 1G, 3G |
9490F | F/9.7 | 84 x 84 | 1G, 3G |
9490EF | F/7.4 | 102 x 102 | 1G, 3G |
9150 | F/3.5 | 102 x 102 | 1G, 3G |
9150X | Call | Call | Echelle |
转塔配置
提供多种转塔配置。由于机械限制,某些单色仪中无法使用某些转塔配置。
1G转塔
单光栅转塔允许手动选择光栅。 每个光栅都安装在运动光栅支架上
1G, Single Grating Turrets: Manual Grating Selection | ||
Part # | Grating Size (mm x mm) | Number of Gratings |
120-8039 | 64 x 64 | 1 |
120-8040 | 84 x 84 | 1 |
120-8041 | 102 x 102 | 1 |
3G转塔
3G转台允许电动光栅选择。磁带上*多可安装3个光栅。盒式磁带垂直于正弦驱动器的旋转轴旋转。盒式磁带可以与其他盒式磁带一起重新放置,允许无限的光栅选项
3G, Motorized Turrets allow for com- puter controlled grating selection: | ||
Part # | Grating Size (mm x mm) | Number of Gratings |
120-8056 | 64 x 64 | 3 |
120-8057 | 84 x 84 | 3 |
120-8058 | 102 x 102 | 3 |
内部配置:
Step 2: Input Port Configuration | ||
Part # | Model | Description |
120-8044 | 9000-HI-IN | Fixed Side Input Port |
120-8032 | DPIN-HI-MAN | Manual Dual Input Port |
120-8072 | DPIN-HI-MOT | Motorized Dual Input Port |
Step 3: Output Port Configuration | ||
Part # | Model | Description |
120-8045 | 9000-HI-OUT | Fixed Side Output Port |
120-8033 | DPOUT-HI-MAN | Manual Dual Output Port |
120-8076 | DPOUT-HI-MOT | Motorized Dual Output Port |
* 3G available only for 64x64mm grating size
Step 4:光栅选择
为标准系列单色仪选择光栅时,需要考虑三个基本参数
a)所需波长范围
可用的波长范围由选择的光栅槽密度和单色仪的角度机械限制决定。
b)光栅效率
直纹光栅可以在特定波长范围内闪耀以提高其效率。全息光栅可以被调制,使其在某些波长上比在其他波长上更有效。光栅效率曲线是确定可用于您的应用的*有效光栅的工具。需要注意的是,当光栅在单色仪中使用时,光栅效率曲线并不能代表预期的准确效率,因为光栅效率曲线是在小角度下获得的。
c)所需分辨率和带宽
分辨率是测量仪器分离相邻谱线的能力。分辨率通常以纳米为单位。带宽(或带通)是在任何时候落在输出端口上的波长范围,也以nm为单位。这是一个重要的参数,当集成相机,如线阵或CCD的输出端口的单色。
Step 5:镜面和光栅涂层
标准镜面涂层是带有MgF2保护层的铝。 标准光栅具有铝涂层。 金属涂层。 如果您的应用受益于不同的镜面或光栅涂层,请在订购时参考以下代码。
Mirror or Grating Coating | Useful Range | Code |
Aluminum (MgF2 coating) | 350nm + | Standard |
UV enhanced Aluminum | 200nm + | -UV |
Silver | 400nm + | -S |
Gold | 600nm – Far IR, best option for NIR | -G |
Step 6:映像选项
由于使用离轴球面镜,标准的Czerney-Turner型单色仪在输出光束中存在像散。通常,散光不是问题。对于成像应用,使用环形反射镜补偿光学系统中的固有像散,从而在输出端口产生输入狭缝的直接像。这是研究诸如快速动力学之类的现象的重要选择。
双通选项(-DP)
此选项将双通道选项添加到9490或9150单色仪中。使用双通道选项,可以有效地将单色仪的相互线性色散降低两倍。
通过减小色散,也可以将单色仪可达到的*终分辨率降低两倍。
双通系统通过在单色镜的入口和出口附近引入拾取镜来发挥作用。拾取镜收集通过单色仪系统(准直镜,光栅和摄像机镜)的单次通过的光,然后重定向光以进行第二次通过。
带有双程选项的单色仪也可以单程使用。为了利用单通选件,将双通镜降低了。电动和手动选件均可将双反镜移入或移出位置。在单程模式下,重新定向到单色仪的光通常沿着光轴发送。使用双通选件时,入射光必须平行于光轴发送,并垂直平移约6mm。垂直平移允许双通道光学器件有效收集和重定向单通道光。双通光束将离开单色仪,该单色仪从光轴垂直平移的量与光发送到单色仪中的光量相同。
只有在使用单色仪的前入口和出口时,双通选项才可用。相机可以使用双程选件,但是应安装相机,使其与光轴垂直平移,以便双程光将落在相机活动区域的中心。