1/1

CHEMUSB4-VIS-NIR分光光度计

报价 面议

品牌

海洋光学

型号

CHEMUSB4-VIS-NIR

产地

美洲美国

应用领域

暂无
该产品已下架

CHEMUSB4-VIS-NIR分光光度计是一款小型系统,其包括下列组件:高端内置光源,一台USB型光谱仪,适用于1cm试管的支架以及高速电子设备。它能够提供实时的、基于PC技术的光谱测量以及能在25ms内获取370-985范围的全光谱。

 

产品特点:

·         全集成的预装系统覆盖370-985nm波长范围,光学分辨率为1.0FWHM
·         微型系统是实验室和教学的理想选择
·         直接连接有氘钨灯源/紫罗兰色LED光源与样品支架
·         吸光率小至0.01
·         通过USB2.0接口可快速地将光谱仪与计算机相连

 

Direct-attach Light Source
The CHEMUSB4-VIS-NIR uses the USB-ISS-VIS combination sample holder (1-cm cuvette) and violet LED-boosted tungsten light source for measuring relative absorbance. The light source boosts signal in the blue and provides over 45,000 hours of use.
 
Programmable Microcontroller
The CHEMUSB4-VIS-NIR uses our USB4000 Spectrometer. The USB4000 features an onboard programmable microcontroller that provides you with considerable flexibility in controlling the spectrometer and accessories. Through a 22-pin connector, you can implement all operating parameters in the software: control light sources, create processes, and retrieve information on external objects. You have access to 8 user-programmable digital Inputs/Outputs for interfacing to other equipment.
 
Modular Design
Ocean Optics offers complete line of fiber optic sampling accessories and teaching tools to further enhance your CHEMUSB4-VIS-NIR system. Most accessories have SMA 905 connectors for application flexibility; changing the sampling system is as easy as unscrewing a connector and adding new components or accessories.
For even more flexibility, consider the CHEM4-VIS-FIBER. An optical fiber based system, the CHEM4-UV-FIBER lets you quickly and easily couple fiber optic accessories, such as reflection probes or transmission dip probes, to the system's light source.
 
Plug-and-Play Operation
The CHEMUSB4-VIS-NIR interfaces to a PC, PLC or other embedded controllers via USB 2.0 or RS-232 serial port. When using the serial port, the system requires a single 5-volt power supply (not included). Data unique to each spectrometer is programmed into a memory chip on the USB4000; our spectrometer operating software reads these values for easy setup and hot swapping among PCs.
 
Serial port operation tips: When using the serial port, the USB4000 requires a single 5-volt power supply (not included). Also, SpectraSuite Spectroscopy Software does not support spectrometer operation via the serial port. However, using the included Serial Port Command Set, you can write your own software that makes serial port operation possible.
 
Specifications
Physical
Spectrometer dimensions:
89.1 mm x 63.3 mm x 34.4 mm
Spectrometer weight:
190 grams
Light source dimensions:
40.7 mm x 88.8 mm x 34.1 mm
Light source weight:
130 g
Detector Specifications
Detector:
Toshiba TCD1304AP Linear CCD array
Pixels:
3648 pixels
Pixel size:
8 μm x 200 μm
Pixel well depth:
100,000 electrons
Signal-to-noise ratio:
300:1 (at full signal)
A/D resolution:
16 bit
Corrected linearity:
>99.8%
Sensitivity:
130 photons/count at 400 nm; 60 photons/count at 600 nm
Optical Bench
Design:
f/4, Asymmetrical crossed Czerny-Turner
Focal length:
42 mm input; 68 mm output
Entrance aperture:
25 µm wide slit
Grating:
Grating #2
OFLV filter:
OFLV-350-1000
Fiber optic connector:
SMA 905 to 0.22 numerical aperture single-strand optical fiber
Spectroscopic
Wavelength range:
370 to 985 nm
(The actual range typically exceeds what's listed here. The range listed is where you will see changes as small as 0.01 absorbance units.)
Optical resolution:
1.0 nm FWHM
Signal-to-noise ratio:
300:1 (at full signal)
A/D resolution:
16 bit
Dark noise:
50 RMS counts
Integration time:
3.8 ms to 10 seconds
Dynamic range:
2 x 108 (system), 1300:1 for a single acquisition
Stray light:
<0.05% at 600 nm; 0.10% at 435 nm
Light Source/Sample Holder
Power consumption:
160 mA @ 5 VDC; external power supply (included)
Pathlength:
1 cm
Cuvette shape:
Square
Light source:
Tungsten halogen and violet LED
"Z" dimension:
15 mm
Bulb life (hours):
45,000
Time to stabilized output:
~5 minutes
Electronics
Power consumption:
250 mA @ 5 VDC
Data transfer speed:
Full scans to memory every 5 ms with USB 2.0 port, 18 ms with USB 1.1 port
Inputs/Outputs:
Yes, 8 onboard digital user-programmable GPIOs
Analog channels:
No
Auto nulling:
Yes
Breakout box compatible:
Yes, HR4-BREAKOUT
Trigger modes:
4 modes
Strobe functions:
Yes
Connector:
22-pin connector
Computer
Operating systems:
Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port
Computer interfaces:
USB 2.0 @ 480 Mbps (USB1.1 compatible); RS-232 (2-wire) @ 115.2 K baud
Peripheral interfaces:
SPI (3-wire); I2C inter-integrated circuit 
查看全部