报价 ¥50万 - 100万
Integrated DPSS pump laser and OPO system
Up to 90 mJ in range 650 – 2600 nm
100 Hz or 50 Hz pulse repetition rate
Certification ready
Quiet operation < 60 dB
Ultra-wide signal tuning range from 650 to 1300 nm
Fully motorized wavelength tuning
Fast Wavelength Switching
Externally triggerable
High, up to 90 mJ pulse energy from OPO
100 Hz or 50 Hz pulse repetition rate
Certification ready
Quiet operation < 60 dB
Integrated DPSS pump laser and OPO into a single housing
Fiber bundle or fiber
Signal and Idler through the same output (optional)
Integrated energy meter (optional)
Electromechanical output shutter with laser self-test capability
PhotoSonus X is a perfect solution for photoacoustic imaging in pre-clinical and clinical use and when fast sample scanning is required. Having high output energy of up to 90 mJ at the peak, a broad wavelength tuning range from 650 to 2600 nm, high pulse repetition rate up to 100 Hz and fast wavelength switching makes it a perfect photoacoustic imaging source for gaining high-resolution images and ensuring high data acquisition rate. Moreover, being built on a diode pumped solid-state laser platform, PhotoSonus X assures significantly quieter operation (< 60 dB) compared with flash-lamp pumped lasers, which is very beneficial for clinical use.
Diode pumped laser technology and well-engineered system design ensures high reliability and low-cost system operation. PhotoSonus X output can be coupled with almost any type of fiber bundle.
With additional options of an internal energy meter and electromechanical shutter with laser self-test capability, PhotoSonus X can be ready for certification in clinical photoacoustic applications.
Due to continuous improvement, all specifications are subject to change without notice. The parameters marked typical are not specifications. They are indications of typical performance and will vary with each unit we manufacture. Unless stated otherwise all specifications are measured at 700 nm.
Measured at the free space output. See tuning curves for typical energy levels at different wavelengths.
Other fixed pulse repetiton rates are available upon request.
FWHM measured with photodiode featuring 1 ns rise time and 300 MHz bandwidth oscilloscope.
At 700 nm or higher wavelength.
Measured at the free space output at 700 nm wavelength.
Using external chiller.
Note: Laser must be connected to the mains electricity all the time. If there will be no mains electricity for longer that 1 hour then laser (system) needs warm up for a few hours before switching on.
Related applications: Biomedical Photoacoustic Imaging
Related applications: Biomedical Photoacoustic Imaging
Related applications: Biomedical Photoacoustic Imaging
Related applications: Biomedical Photoacoustic Imaging
Related applications: Biomedical Photoacoustic Imaging
Related applications: Biomedical Photoacoustic Imaging
Related applications: Biomedical Photoacoustic Imaging
1年
是
有
一人次
质保期内一次
全天候电话邮件微信远程连接支援服务
一周内到达用户现场开始维修
相关产品