方案下载应用领域 | 环保 |
检测样本 | 环境水(除海水) |
检测项目 | 有机污染物>卤代有机化合物 |
参考标准 | EPA方法537 |
Raptor C18提供出色的分辨率,短总循环次数。更快的分析效率,2.7µ 颗粒。EPA方法537。全氟烷基酸是人造化合物用作制造各种表面活性剂产品,如消防泡沫,涂料添加剂,纺织品及清洁用品。他们已检测到世界各地的环境,并在世界各地使用非常大的数量。这些化合物是环境退化过程的主因.它们被广泛分布在土壤,空气,地下水,城市垃圾填埋场,和全氟辛烷磺酸富集电位酸(PFOS)和全氟辛酸(PFOA),特别是,对环境和人类健康构成潜在的不利影响。
Raptor™ C18 SPP 5 µm core-shell silica particle columns
offer excellent resolution for fluorochemicals with short
total cycle times. For even faster analysis, 2.7 µm core-shell
particles are available.
• Meets EPA Method 537 requirements.
• Unique, robust Raptor™ C18 column design increases
instrument uptime.
Perfluorinated alkyl acids are man-made fluorochemicals
used as surface-active agents in the manufacture of a variety
of products, such as firefighting foams, coating additives,
textiles, and cleaning products. They have been detected in
the environment globally and are used in very large quantities around the world. These fluorochemicals are extremely
persistent and resistant to typical environmental degradation
processes. As a result, they are widely distributed across the
higher trophic levels and are found in soil, air, groundwater,
municipal refuse, and landfill leachates. The toxicity, mobility,
and bioaccumulation potential of perfluorooctanesulfonic
acid (PFOS) and perfluorooctanoic acid (PFOA), in particular,
pose potential adverse effects for the environment and human health.
Perfluorinated alkyl acid analysis can be challenging because
these compounds are chemically different from most other
environmental contaminants. They are difficult to quantify
because some are more volatile than others, and they also
tend to be more hydrophilic and somewhat reactive. In addition, fluorochemicals are present in polytetrafluoroethylene
(PTFE) materials, so excluding the use of any PTFE labware
throughout the sampling and analytical processes (including
HPLC solvent inlet tubing) is essential for accurate analysis.
Typically, perfluorinated alkyl acids are analyzed by LC-MS/
MS methods, such as EPA Method 537, but long analysis times
can significantly limit sample throughput.
As written, the EPA 537 requires a 27-minute cycle per
sample, but the method does allow flexibility in the column
used as long as there is sufficient resolution for the MS dwell
time for all compounds in a specific retention time window.
In the first chromatogram below, all target perfluorinated
alkyl acids were analyzed on a Raptor™ C18 column in under
8 minutes with a total cycle time of 10 minutes—resulting
in an approximately three-fold faster analysis than the EPA
method. While this analysis is significantly faster, there is
no sacrifice in peak resolution or selectivity, meaning all
fluorochemicals are easily identified and they elute as highly
symmetrical peaks that can be accurately integrated and
quantified by MS/MS. If PFOA and PFOS are the only target
fluorochemicals, the analysis can be further optimized, which
results in a fast, <2-minute separation with a total cycle time
of just 4.5 minutes, as shown in the second chromatogram.
Whether labs conducting perfluorinated alkyl acid analysis
by LC use longer target analyte lists or focus just on PFOA and
PFOS, the excellent peak shapes and separations achieved
here result in consistent, accurate quantification with much
shorter analysis times. By switching to a Raptor™ C18 column,
labs can process more samples per hour while still meeting
fluorochemical method requirements.
食用油中过氧化值快速检测
可见分光光度计分析蜂蜜色度和HMF含量的测定
Rt-XLSulfur低硫化合物分析专用柱ppb级硫化物分析
相关产品
核地新款静电吸收电子测氡仪-土壤/环境/建材/水质
闪蒸仪液态烃闪蒸气化取样气体进样器
百道亨基础性干式气体流量计校准仪
百道亨DCal通用型高精度气体流量计校准仪
百道亨气体流量数字皂膜流量计
百道亨多量程测量校准电子气体皂膜流量计
百道亨测定空气粉尘浓度大流量粉尘采样器
北京劳保所防爆型连续可调粉尘采样仪器BDHIFC-2
百道亨HL5000恒流空气粉尘采集器粉尘个体大气采样器
北京劳保所BDHFC-4粉尘浓度测定短时间空气粉尘采样器
北京劳保所BDH5b防爆型长时间个体粉尘采样 仪
专用空气个体长时间大流量粉尘采样仪
百道亨QC-1S作业环境大气定时采样仪器短时间毒物采集
作业环境大气样品挥发性气体毒物短时间大气采样器
BDHQC-3北京劳保所大流量大气作业环境大气采样器
关注
拨打电话
留言咨询