本产品符合中华人民共和国国家标准,环保标准;欧盟EN标准;美国环保总署EPA标准烟枪(Probe)最大温度20度,冷却循环装置温度范围-20-35度可调,冷却池体积18L冲击瓶冷却池大小可选(4个或6个一组)探头到冲击瓶入口距离小于0.5m系统结构紧凑,重量轻,连接简单快速;便于携带运输主机采用触摸屏,菜单操作,内置烟道库,自动计算采样点,使用方便,维护简单译码分辨率0.014 l/min精度: 1,5 %采样体积:Dry-gas meter G2,5分辨率: 0.1 l干气计温度传感器分辨率: 0,1 °C精度: ± 1 % of the measured value (in Kelvin)线性: ± 1 °C (software linearization)压差:范围: 0 ÷ 100 mmH2O (0 ÷ 1000 Pa)分辨率: 0,01 mmH2O (0,1 Pa)精度: ± 1 % of the measured value静压范围: -1000 ÷ 1000 mmH2O (-10.000 ÷ 10.000 Pa)分辨率: 1 mmH2O (1 Pa)精度: ± 1 % of the measured value大气压分辨率: 0,1 mBar精度: ± 2 mBar K 热电偶范围: 0 ÷ 1000 °C分辨率: 0,1 °C 显示: 10”触摸屏数据端口:RS232,USB (on Flash Drive)电源: [230Vac – 50Hz] 8 DECLARATION OF CONFORMITY指示和参考标准: Directive 2006/42/CE – Machine directive Directive 2004/108/CE – Electromagnetic Compatibility (CEM) Directive 2006/95/CE – Low tension Regulation UNI 16911:2013 - Stationary source emissions -- Manual and automatic determination of velocity and volume flow rate in ducts - Part 1:Manual reference method Regulation UNI EN 13284-1:2003 - Stationary source emissions.Determination of low range mass concentration of dust. Manual gravimetricmethod