海水鱼鱼肉中总汞和甲基汞检测方案(紫外分光光度)
检测样品
鱼糜制品
检测项目
重金属
关联设备
共0种
方案详情文
Abstract: In this work we have developed a cost-effectivemethod for the analysis of methyl mercury (MeHg) inseawater fish muscle. The novelty of this method lies in theuse of microwave- assistedextraction with acidic solution (HCl), addition of toluene, and subsequent extraction with cysteine acetate solution where only MeHg is present because of its affinity for cysteine groups. MeHg in cysteine phase and total mercury in the homogenate muscle tissue were determined using a direct Hg analyzer (DMA-80). Validation, precision, and accuracy of the methodwere evaluated and monitored with a tuna fish certified
reference material (CRM 463) containing MeHg.
Keywords Methyl mercury Microwave extraction
Mercury Direct mercury analyzer
北京莱伯泰科仪器股份有限公司为您提供《海水鱼鱼肉中总汞和甲基汞检测方案(紫外分光光度)》,该方案主要用于鱼糜制品中重金属检测,参考标准《暂无》,《海水鱼鱼肉中总汞和甲基汞检测方案(紫外分光光度)》用到的仪器有null。