Amine aerosol testing was conducted at the University of Texas at Austin CO2 capture pilot plant using concentrated piperazine
(3.7 molal) and high temperature flash with cold rich bypass (140 °C). Two methods of piperazine aerosols generation were tested:
H2SO4 injection with a liquid vaporizer injector, and direct injection 20 ppm of SO2 into the synthetic flue gas. A Phase Doppler
Interferometer (PDI) analyzer from Artium Technologies was used to measure piperazine aerosol droplet sizes and distributions at
the absorber gas outlet. A FTIR system with new upgraded heated probes was used to make measurements of total PZ
concentrations at the absorber gas inlet and outlet. A manual sampling train method was used to provide secondary validation of
FTIR and PDI measurements.