当前位置: 其他 > 方案详情

利用两种先进的生物物理技术表征弱结合反应:氢氘交换质谱(HDX-MS)以及差式扫描量热(DSC)

检测样品 其他

检测项目

关联设备 共1种 下载方案

方案详情

A combination of HDX –MS and DSC is capable of revealing important structural details for biopharmaceuticals that cannot be obtained using other techniques HDX can map changes in binding regions and define structure of weak binding sites DSC characterization ensures highest quality structural data for differentiating weak binding molecular variants HDX-MS & DSC provide powerful, flexible analysis tools for DD, R&D and QC

智能文字提取功能测试中

Dile Holton, PhD1Colette Quin, PhD.1Joomi Ahn2St John Skilton,PhD2Ying Qing Yu, PhD"器信息网 Characterizing Weak Binding Events with TwoAdvanced Biophysical Techniques: HydrogenDeuterium Exchange (HDX-MS) and DifferentialScanning Calorimetry(DSC) Background: The objective of this study was to probe the conformational change caused bya site specific mutation in a human immunoglobuin G (lgG). Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) andDifferential Scanning Calorimetry (DSC) complement one another and havethe laboratory-proven sensitivity and reproducibility to successfullycharacterize the structure and function of binding molecules. The HDX-MS/DSC data sets enabled a clear, comprehensive characterizationof peptide maps and thermodynamic stability changes that help define weakbinding events. HDX-MS Experiments/Data Pulsed Labeling Denaturant + c 2.0 HDX-MS data for Variant 1 & 2 indicates 3 AA substitutioninfluences molecular structure Effective mapping of engineered changes in weak bindingsites 1- TAInstruments, New Castle, DE;2-Waters LLC, Milford, MA (A) nanoACQUITY UPLC HDX -Waters (B) Xevo G2 Q-TOF MS -Waters (C) Nano DSC Autosampler System- TA Instruments DSC Experiments / Data Temperature(C) Tm AHyH1 Tm2 AHvH2 Tm: AHvH3 (℃) (kJ/mol) Aw(℃) ( (kJ/mol) Aw2(C) (kJ/mol) Aws Var 1 57.6 376 1.4 83.4 444 4.7 88.4 640 1.4 Var 2 57.8 406 1.6 83.1 420 5.6 889.0 557 2.1 control 65 477 1.1 83.6 410 5.3 889.1 619 1.8 °Tm shift in Variant 1 & 2 indicates molecular structure changes inweak binding sites ° Data from DSC thermogram consistent with HDX-MS data Summary / Conclusion: A combination of HDX-MS and DSC is capable of revealing importantstructural details for biopharmaceuticals that cannot be obtained using othertechniques HDX can map changes in binding regions and define structure of weakbinding sites DSC characterization ensures highest quality structural data fordifferentiating weak binding molecular variants HDX-MS & DSC provide powerful, flexible analysis tools for DD, R&Dand QC

关闭
  • 1/1

产品配置单

TA仪器为您提供《 利用两种先进的生物物理技术表征弱结合反应:氢氘交换质谱(HDX-MS)以及差式扫描量热(DSC)》,该方案主要用于其他中null检测,参考标准《暂无》,《 利用两种先进的生物物理技术表征弱结合反应:氢氘交换质谱(HDX-MS)以及差式扫描量热(DSC)》用到的仪器有TA仪器+差示扫描量热仪+NANO DSC。

我要纠错

推荐专场

相关方案