高盐样品中总有机碳含量检测方案(TOC分析仪)

检测样品 无机盐

检测项目 总有机碳含量

关联设备 共0种 下载方案

方案详情

TOC 除了用于分析地表水和废水外,很大的一个应用领域是测定高盐样品中总有机碳含量。multiN/C3100可成功的实现高盐样品的测定

智能文字提取功能测试中

analytikjenaAGanalytical solutions 01/01 SP_TOC_01_01_e Recovery of a TOC Standard after injection of a saline solutionmulti N/C 1lntroduction In the field of TOC analysis, not only wastewater or surface water, but also seawater playsan important part. The specificity of the latter is that the salt content of this matrix is veryhigh. Such salt loads, however, can also be found in chemical industry, on garbage dumpsand in electroplating industry. Analysis The aim of the investigation was to test the multi N/C analyzer to find out to what extent therecoveroyf oaf1 amg/l standard remains stable. The procedure was as 1follows:A 1 mg/l potassium hydrogen phthalate standard with an addition of 140% NaCl wasanalyzed altogether six times with 20 repeat measurements each. After every secondanalysis, a control measurement with a pure potassium hydrogen phthalate standard wastaken to keep track of the recovery. A five times determination with subsequent averaging ofthe test standard was regarded as sufficient. The mean of the 14 % NaCl blank also resultedfrom the random sampling between the salt-loaded standards. With this NPOC method, the injection volume was optimized to 500 pl. Blank+14%NaCl=1.01 mg/l In the following evaluation, first one refers to the introduced salt content, which entered thesystem through the blanks and the standards. The blank has already been taken intoaccount and subtracted accordingly. 01/01 SP_TOC_01_01_e Number of injections (500 pl each) Blank14% NaCl 1 mg/I KHP14% NaCl Salt content.absolute Salt content,total 5 1.13 mg/l 0.35g 0.35 g 20 0.92 mg/l 1.40 g 1.75g 20 1.05 mg/l 1.40 g 3.15 g 5 0.89 mg/l ---- 0.35g 3.50g 20 1.11 mg/l 1.40 g 4.90 g 20 1.07 mg/1 1.40 g 6.30 g 5 1.06 mg/l 0.35 g 6.65 g 20 1.03 mg/l 1.40g 8.05 g 20 1.10 mg/l 1.40 g 9.45g 5 0.96 mg/I --- 0.35g 9.80 g SUM: 140 From the results, first one can conclude that 140 injections with saline water got into thesystem. These contained about 10 g of salt. In addition, the comparison is to be presented showing the recovery of a standard withoutsalt load after the measurement of a saline-loaded standard. analytical solutions 01/01 SP_TOC_01_01_e ◎ 2001 Analytik Jena AG Phone +49 (0) 36 41/77-70Fax +49 (0) 36 41/77-92 79

关闭
  • 1/3
  • 2/3

还剩1页未读,是否继续阅读?

继续免费阅读全文

产品配置单

耶拿分析仪器(北京)有限公司为您提供《高盐样品中总有机碳含量检测方案(TOC分析仪)》,该方案主要用于无机盐中总有机碳含量检测,参考标准《暂无》,《高盐样品中总有机碳含量检测方案(TOC分析仪)》用到的仪器有null。

我要纠错

相关方案